• Title/Summary/Keyword: 침전지

Search Result 129, Processing Time 0.027 seconds

Evaluation of hydraulic behavior within parallel arranged upflow sedimentation basin using CFD simulation(II) -A CFD methodology for the design of distribution channel for improving inlet equity (CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(II) - 침전지 내 유입유량 균등성 향상을 위한 유입 분배수로 개선 -)

  • Park, No-Suk;Kim, Seong-Su;Choi, Jong-Woong;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.217-223
    • /
    • 2014
  • In order to suggest the methodology for improving the equity of flow distribution in open channel with multiple outlet, CFD simulations were carried out for actual scale distribution channel being operated in domestic G_WTP(Water Treatment Plant). Also, before and after installing the longitudinal multi hole(diameter=250 mm, 116 holes) baffle suggested by this research, turbidity measurements data were collected for evaluating the effects of hydraulic modification for inlet flow equity. From the both results, total turbidity of settled water was lowered by 30 % and equity of flow distribution was improved about 60 % compared with before hydraulic structure modification.

Evaluation of water treatment characteristics at the improved circle secondary settling basin (개량 고속원형침전지의 수처리 특성 평가)

  • Jang, Honggyu;Cho, Youngman;Kim, Changwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.609-614
    • /
    • 2014
  • Researcher of this study improved conventional circle secondary settling basin, through the way such as extend of inlet pipe length, introduction of device for inducting uniforming of flow, keeping of height of sludge interface. Also, we compared conventional circle settling basin to improved circle settling basin the water treatment efficiency. Result of research, when SVI is average 117, improvement rate of SS and BOD were 51.0%, 37.0% approximately compared to conventional settling basin. And when SVI is average 178, improvement rate of SS and BOD were 22.7%, 36.0% approximately. Also when SVI is average 196, improvement rate of SS and BOD were 24.7%, 30.3% approximately. When it's winter, improvement rate of SS, BOD, COD, TN and TP were 20.6%, 17.9%, 13.9%, 13.5%, 12.4% approximately. Therefore, we can be the judge, this improved settling basin can be used as the final settling basin in the waste water treatment plant.

Application of a CFD Model for the Design of a Settling Basin Inlet Structure (침전지 유입부 설계를 위한 CFD 모형의 적용)

  • Kim, Nam Il;Kim, Dae Geun;Yu, Chang Hwan;Kim, Tae Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.318-322
    • /
    • 2005
  • We applied a commercially available computational fluid dynamics model, FLOW-3D, to design a settling basin inlet structure for the intended O sewage plant. In addition, we analyzed the extent to which the inlet sewage water was distributed as a result, firstly, of the location and width of a submerged baffle wall and, secondly, of the opening ratio of a baffle wall with opening holes. The application results show that the flow is unstable due to the generation of eddies in both sides of the submerged baffle wall when the submerged baffle wall is located close to the inlet. The eddies and subsequent instability also occur when the submerged baffle wall is located close to the baffle wall with opening holes. Moreover, the discharge that passes through the midsection of the settling basin increases as the width of the submerged baffle wall increases. At the O sewage plant, when the submerged baffle wall with a width of 2.4 m was located 2 m from the inlet structure and the opening ratio of the baffle wall was 7 percent, the most satisfactory distribution of the inlet sewage water occurred at the entrance of the settling basin.

Water Quality Improvement Using a Contact Oxidation Canal with Sedimentation Basin (침전접촉산화수로를 이용한 수질 개선)

  • Kim, Won-Jang;Park, Sang-Hyun;Kim, Hyung-Joong;Kim, Tae-Kyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.3
    • /
    • pp.143-149
    • /
    • 2001
  • A contact oxidation canal system with sedimentation basin was installed to study the efficiency of water quality purification. The primary sedimentation basin with 60 min of HRT (Hydraulic Retention Time) included in the system was aimed to sediment pollutants in the water and the deposit being released by the drainage culvert located at the bottom of the system. The oxidation canal aerated by nozzle was to contact the pollutants and oxygen in the surface of plastic filter to purify the water. Discharge, HRT, length of the oxidation canal were $200\;m^3/day$, 90 min, 20 m, respectively. The treatment efficiency of total nitrogen was lower compared with other water quality items such as SS, BOD, TP because the anoxic condition for denitrification was not ensured after the oxidation canal. However, $25%{\sim}89.6%$ of SS, $75.0%{\sim}91.5%$ of BOD, $44.3%{\sim}95.3%$ of TP were removed in this system. Overall, the results indicates that this system appears to have a potential capability for water quality improvement of the reservoirs or the canals in the agricultural watershed.

  • PDF

Reuse and Concentration of Sewage by Forward Osmosis Using Fertilizer as Draw Solution (비료 유도용액의 정삼투를 이용한 하수의 재이용 및 농축)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.122-131
    • /
    • 2019
  • In order to reuse and concentrate the sewage, a forward osmosis using fertilizer as draw solution was applied. Sewage-1, which is the supernatant after settling for 30 minutes for the primary settling basin influent, and Sewage-2, which is the supernatant after settling for 30 minutes for the effluent, and Sewage-3, which is the filtrate filtered through a $1{\mu}m$ cartridge filter for the effluent were tested. Eight draw solutions of $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$, and $KHCO_3$ were used in consideration of osmotic pressure, solubility and pH. In the case of Sewage-3, the permeate flux was almost similar to that of the discharge water of the sewage treatment plant, and was larger than that of Sewage-1 and Sewage-2. $NH_4H_2PO_4$ was the smallest, and $NH_4NO_3$ was the largest in the specific reverse solute flux. $NH_4H_2PO_4$ was found to be most useful for the reuse and concentration of sewage because it contains nitrogen and phosphorus, which are the major components of fertilizer, as well as low specific reverse solute flux. When $NH_4H_2PO_4$ was used as the draw solution, the concentration factor after 24 hours for Sewage-3 was 1.72.

중소규모 하수처리장의 탈질$\cdot$탈인 PICD 시스템 실용화기술개발

  • 한상배;노명규;정보림;장덕;서성철;홍기호;성문성
    • Environmental engineer
    • /
    • s.172
    • /
    • pp.70-81
    • /
    • 2000
  • G-7 환경기술연구개발 3단계사업의 일환으로 `98년도부터 (주)그린기술산업과 건국대학교에서 연구 수행중인 PICD(Phased Isolation Intra Clarifier Ditch)시스템은 중소규모 하수처리장의 유입부하변동에 대해 안정적이고, 신축적인 운전이 가능한 탈질$\cdot$탈인 공정이다. 국내는 물론 미국 및 중국 특허를 획득한 본 시스템은 기존의 내부순환포함 다단 완전혼합형 영양염류제거공정과는 달리 침전지를 산화구에

  • PDF

Improvement of Cooling Water Quality by Coagulation and Sedimentation (응집침전에 의한 냉각수질 향상)

  • Woo, Dal-Sik;Jo, Kwan-Hyung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.369-371
    • /
    • 2008
  • 본 논문은 철강공장의 냉각수 처리 시스템에서 고로 집진수를 대상으로 한 응집교반실험을 실시한 결과, 주기적인 관 갱생작업(산세척)과 분산제의 주입이 필요하며, 음이온 고분자응집제에 양이온 고분자응집제를 첨가하여 사용할 경우에 탁도 제거측면에서 우수하였다. 급속교반 후 완속교반을 적용할 경우 급속교반 후 침전보다 탁도 제어 효과가 더 우수한 것으로 관찰되었으므로, 침전지의 처리효율을 증가시키기 위해서는 급속교반과 완속교반이 동시에 필요하였다.

  • PDF

Formation of Sedimentation Pool within Irrigation Reserviors for Water Quality Improvement (저수지 수질개선을 위한 저수지 내 침전지 조성)

  • 박병흔
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.1
    • /
    • pp.73-82
    • /
    • 2000
  • Large quantitive of polllutants are washed into reservoirs during storm events. These polllutants contribute to eutrophication, such as algal blooms and fish kills. This study was conducted for the purpose of assessing the pollutant removal possibilities of sedimentation pool formed by deep dredging of a reservoir inlet. Water quality data were collected in the Masan reservoir, whose inlet has been dredged deep like sedimentation pool. The average concentration of chemical oxygen demand(COD) , toatal nitrogen(T-N) and total phosphrous(T-P) in the deep dredged area were 8.7 ~20.5mg/ι (T-N), 0.17~0.84mg/ι(T-P), which were 4.9%(COD), 29.0%(T-N) and 44.8%(T-P) higher than those of middle part of the reservior. The texture of sediment in the dredged area was silty loam, while that of the middle part was sandy clay loam. Organic matter contents, T-N and T-P of the bottom soil in the dredge area showed higher values than the middle part of the reservoirs. From these results, it was considered thedeep dredged area in the inlet of reservoir might play a key role to settle pollutant particulate. Based on the result of water quality analysis, deep dredging of the reservoir inlet could be assessed to reduce T-N and T-P of the reservoir about 6.5% , 8.3%, respectively. However, the effect of the sedimentation pool would be raised if the settled particles were taken into account in assessing water quality improvement for the reservoir. Accordingly, dredging of a reservoir inlet to make a shape of sedimentation pool is recommended for water quality improvement of reservoir in the stage of dredging plan.

  • PDF

The Effect of Open Ratio of the Inlet Baffle on Hydraulic Behavior within a Rectangular Sedimentation Basin (장방형 침전지 유입 정류벽 유공비의 지내 수리거동에 미치는 영향 연구)

  • Park, No-Suk;Kim, Seong-Su;Lim, Sung-Eun;Lee, Doo-Jin;Seo, In-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.345-352
    • /
    • 2009
  • The purpose of inlet baffle is to distribute the flow uniformly over the entire cross-sectional area of the sedimentation basin. The goal when designing this baffle is to achieve some head loss while keeping the velocity gradients through the ports equal to the velocity gradient in the end of the flocculator, so as to not break up the flocs. Sedimentation tank performance is strongly influenced by hydrodynamic and physical effects such as inlet design. This study was conducted to evaluate the effect of open ratio of the inlet baffle on hydraulic behavior within a rectangular sedimentation basin using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 18 points in the full-scale sedimentation basin at Y water treatment plant. Good agreement was obtained between the CFD predictions and the experimentally measured data. From the simulation results of the existing basin with 7.4 % open ratio, it was investigated that extreme decrease in velocity occurred in the middle of basin. Since then, flow features was unstable. The region which the velocity decrease rapidly moved forward to the flow direction in proportion to the increase of inflow velocity. Also, it was investigated that the flow characteristic of 6.0 % open ratio was significantly different from 7.4 % open ratio at the same configuration condition. These results are a clear indication that inflow momentum and open ratio are the parameters affecting the characteristics of hydraulic patterns. The influence of these parameters on the sedimentation performance requires further study.