• 제목/요약/키워드: 침수사고

Search Result 88, Processing Time 0.032 seconds

Analysis of Electric Shock Accidents and Check Results in Domestic and Foreign low-Voltage Handhole (국내.외 저압지중함 감전사고사례 및 점검결과의 분석)

  • Kim, Chong-Min;Han, Woon-Ki;Bang, Sun-Bae;Kim, Han-Sang;Shim, Keon-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.124-131
    • /
    • 2008
  • Recently underground electrical power distribution is increased because people attach importance to aesthetics of the downtown areas. Lew-voltage handhole of underground distribution line for joint and branch point is mainly installed at the sidewalk. So, pedestrian can get a electric shock if fault is occurred in the low-voltage handhole. Furthermore the street was flooded by recently an unusual change in the weather. Fault is occurred in the low-voltage handhole that may create a shock hazard for the human body because a person's body resistance lower due to effect of water. This paper analyses causes of electric shock accidents and check results at the low-voltage handhole. At a result of analysis, the causes of electric shock accidents in domestic and foreign low-voltage handhole are same but environmental conditions of low-voltage handhole are different In the future, the analytical data can be applied to prevent the electric shock at the low-voltage handhole, and can be used to basic data for the improving installment of low-voltage handhole.

Review of Peak Breach Outflow Predictors in Dam-Failure Modeling (댐붕괴 모델링을 위한 첨두붕괴유출량 예측식 검토)

  • Kim, Keuk-Soo;Kim, Ji-Sung;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1846-1851
    • /
    • 2010
  • 댐붕괴 모델링에 관한 연구가 활성화된 시기는 미국 Baldwin Hills 댐(1964)과 Lower Van Norman(San Fernando) 댐(1971) 붕괴 사고 이후이며 1970년대 발생한 Buffalo Creek 댐(서부 버지니아, 1972), Teton 댐(아이다호, 1976), Laurel Run 댐/Sandy Run 댐(펜실바니아, 1977), Kelly Barnes 댐(조지아, 1977) 붕괴 사고로 인해 미국 댐 안전 관리 프로그램의 포괄적 재검토의 필요성이 제기되었다. 국내에서도 연천댐 붕괴(1996년)와 장현저수지와 동막저수지의 붕괴(2002년)로 하류에 위치한 가옥 및 농경지 침수로 인해 재산피해가 발생한 바 있으며, 2005년 비상대처계획 수립을 의무화하는 제도가 도입되었다. 오늘날 댐 붕괴와 붕괴로 인한 유출 수문곡선을 분석하는데 이용 가능한 수많은 도구들이 존재하고 있다. 가장 잘 알려져 있으며 가장 널리 이용되는 모형은 NWS Dam-Break Flood Forecasting Model(DAMBRK; Fread, 1977)이며 국내 댐 저수지 비상대처계획 수립을 위해 많이 이용되고 있다. DAMBRK 모형의 입력자료는 붕괴지속시간, 결괴부측면경사, 최종결괴부바닥표고, 댐붕괴시작수위 등이 요구되며, 이 중 결괴형성과정에 관련된 매개변수의 선정을 위해서는 댐붕괴 사례연구 자료가 활용되고 있다. 모형으로부터 도출된 붕괴유출수문곡선에 대한 적정성 평가는 과거 경험, 공학적 판단, 첨두유량 예측식에 의해 수행되고 있으며 가장 객관적인 기준이라 판단되는 첨두유출량 예측식은 사례연구 자료의 부족으로 인해 높은 불확실성을 안고 있다. 본 연구는 최근까지 개발된 댐결괴 첨두유출량 예측식을 기반으로 국내 건설된 댐의 대다수를 차지하는 필댐에 대해 댐높이, 댐형식별로 예측식의 적정성을 평가하였다.

  • PDF

Research of Electric Leakage Characteristic by Magnetic Field (자계를 이용한 누전특성조사)

  • Kim, Tag-Yong;Oh, Yong-Chul;Jeong, Han-Seok;Yun, Su-Jin;Yoo, Jae-Sik;Choi, Myeong-Ho;Ji, Yong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2108-2109
    • /
    • 2008
  • 매년 증가하고 있는 누전사고에 대한 대책수립을 위해 누전검출장치 및 누전조사작업을 시행하고 있지만, 대부분 전압변화 및 영상전류 및 z임피던스에 의한 계측이 주를 이루고 있다. 본 논문에서는 누전지역에서의 누설전류에 자속밀도 분포를 조사함으로 손쉬운 누전검출장비 개발 및 비접촉에 의한 누전검출장비 개발과 누전환경에서의 기초 연구자료를 제공하고자 정상선로에서의 자속밀도 분포 및 전압변화에 따른 자속밀도 분포를 조사하였다. 그 결과 정상도선에서는 거리변화에 따른 자속밀도가 감소하였으며, 이에 반해 침수된 누전지역에서는 자속밀도변화가 거의 없음을 확인할 수 있었으며, 전압 증가에 따라 누전지역의 전류값이 정상상태보다 더 크게 변화하는 것을 확인할 수 있었다.

  • PDF

The Qualitative Analysis through the Investigation of the Field Condition at Street Lamps on the Main Street (주요간선 도로에 설치된 가로등의 현장실태조사를 통한 정성적 분석)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Han, Woon-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.101-108
    • /
    • 2005
  • When a heavy rain occurs, many electrical shock victims are produced every year because lamp poles are under water. In order to prevent electrical shock accidents at a street lamp, the investigation was carried out at real field conditions. The investigation was performed about the circuit configuration of a panel board, a wiring method, a grounding conductor, a lamp pole and so on. The related regulation was analyzed and the problems were presented. Also, the domestic and foreign things were compared and analyzed by the investigation of the field conditions, and the related standard was already revised. Through investigating the field conditions and analyzing the related regulation, it is intended to present the real data to establish more effective preventive measures against electrical shock accidents at a street lamp to be installed on the road. In the future, the analytical data can be applied to stabilize other electrical facilities on the road as well as a street lamp, and to reduce the electrical disasters.

Structural Integrity Evaluation of Reactor Pressure Vessel Bottom Head without Penetration Nozzles in Core Melting Accident (노심용융사고 시 관통노즐이 제거된 원자로용기 하부헤드의 구조 건전성 평가)

  • Lee, Yun Joo;Kim, Jong Min;Kim, Hyun Min;Lee, Dae Hee;Chung, Chang Kyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.3
    • /
    • pp.191-198
    • /
    • 2014
  • In this paper, structural integrity evaluation of reactor pressure vessel bottom head without penetration nozzles in core melting accident has been performed. Considering the analysis results of thermal load, weight of molten core debris and internal pressure, thermal load is the most significant factor in reactor vessel bottom head. The failure probability was evaluated according to the established failure criteria and the evaluation showed that the equivalent plastic strain results are lower than critical strain failure criteria. Thermal-structural coupled analyses show that the existence of elastic zone with a lower stress than yield strength is in the middle of bottom head thickness. As a result of analysis, the elastic zone became narrow and moved to the internal wall as the internal pressure increases, and it is evaluated that the structural integrity of reactor vessel is maintained under core melting accident.

Evaluation on th e Wear Fit and Activity of Emergency Escape Breathing Devices for Ship Accidents (선박사고용 호흡구난장비의 착용성 및 활동성 평가 연구)

  • Noh, Jae-Hyeon;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • The use of emergency escape breathing devices (EEBD) is strongly required to protect against toxic gas or flooding caused by ship fires or accidents. Recently developed domestic EEBD products only satisfy the basic performance requirements, but no wear fit and activity performance evaluation has been done for real usage. In this study, the global level test requirements for wear comfort and activity of EEBDs were developed and the open and closed type of domestic EEBD products were evaluated. Poor visibility, longer wear time, breathing resistance, and hose obstruction in an open type and canister obstruction, weight unbalance, and an invisible black breathing bag in the closed type EEBD were estimated to be the main problems that need to be improved.

A Numerical Analysis: Effects of Hydraulic Characteristics of a Hazardous Zone on the Face Stability in Subsea Tunnelling (해저터널 시공중 문제구간의 수리적 특성이 막장의 안정성에 미치는 영향에 관한 수치해석적 연구)

  • Hong, Eun-Soo;Park, Eui-Seob;Shin, Hee-Soon;Kim, Hyung-Mok;Ryu, Dong-Woo
    • Tunnel and Underground Space
    • /
    • v.18 no.5
    • /
    • pp.366-374
    • /
    • 2008
  • Tunnelling under water table induces many geotechnical problems because of groundwater. In subsea tunneling, reduction of face stability can induce flooding in the vicinity of a fracture zone characterized by high permeability and high water pressure. In this study, the effects of high water pressure on the stability of a tunnel face in a limited zone with high permeability(hazardous zone) are analyzed. On the basis of the 'advance core' concept, the seepage force acting on a hypothetical cylinder ahead of a tunnel face is modeled. This study focuses on the hydraulic behavior of the ground ahead of the tunnel face by three-dimensional steady-state seepage analyses. The impact of the hazardous zone on the seepage force and stability of the tunnel face are simulated and analyzed. In light of the analysis results, it is estimated that the distance from the tunnel face to the exterior boundary limit, which the seepage force significantly affects the stability of the tunnel face, of a hypothetical cylinder is approximately 5 times the tunnel radii. Despite the restrictive assumptions of this study, the results are highly indicative regarding the risks of hazardous zones.

An experimental study on the operation mode of rapid flooding protection system in tunnel (축소모형실험을 통한 터널 내 급속침수 차폐자동화 시스템 작동형태에 대한 연구)

  • Kim, Yeon-Deok;Kong, Min-Teak;Hwang, Beoung-Hyeon;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1147-1159
    • /
    • 2018
  • This study focuses on the verification of a rapid protection automation system using an inflatable structure. The inflatable structure is an automatic rapid protection system against human and material damage when the subsea tunnel is flooded. Especially, it is essential for construction and operation of subsea tunnels. In this study, we have experimentally verified the rapid protection automation system using the inflatable structure designed for this problem. In order to verify this, a model tunnel with a 40: 1 reduction ratio was constructed, and air pressure of 0.1 bar and 0.15 bar was injected to divide the tunnel according to the expansion rate at 10 sec and 20 sec. According to the results of the study, the protection efficiency was better at 0.15 bar than 0.1 bar when the expansion structure was expanded, and the protection efficiency and influent control efficiency were different according to the pneumatic injection time of the inflating structure. As a result of this study, it was found that the higher the internal air pressure of the inflated structure and the faster the inflation of rate, the more effectively the inflated structure was inflated. As a result of this study, it is necessary to further study the wedge type structure which is useful for the storage method of expansion structure, shape and expansion derivative, inhibition of expansion structure during protection and control of inflow water.

Development of Operation Control and Warning System of Movable Weir for River Safety Management (안전한 하천관리를 위한 가동보 방류제어 및 경보 시스템 개발)

  • Kim, Phil Shik;Kwon, Hyung Joong;Lee, Jae Hyouk;Cho, Bum Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.558-558
    • /
    • 2015
  • 하천 시설물은 홍수시 혹은 비상시 운영할 수 있는 경보시스템이나 관리지침 등의 마련이 필수적임에도 불구하고, 현재까지 가동보 시설물에 대한 비상시 운영 메뉴얼 및 경보시스템이 구축되지 못한 실정이다. 4대강 살리기 사업이나 하천정비사업과 같은 대표적인 하천관련 사업에서 단순한 하천 이 치수 목적뿐만 아니라 소수력 발전, 친수공간조성 등의 다목적 활용을 위하여 가동보 설치 사업이 다수 수행되었으며, 현재 국내 하천에 약 1,200여개의 가동보가 설치 운영되고 있다. 이와 같이 다목적 활용을 위하여 가동보의 수요가 급증하는데 반해, 각 설치 현장 상황에 적합한 가동보 운영지침이나 비상경보시스템이 구축되지 못한 실정이며, 적절한 지침 없이 관행적인 가동보 방류로 인한 물놀이 안전사고나 인명피해가 속출하고 있는 실정이다. 2012년 11월에는 하천 제수변 공사를 위해 전주천에 설치한 가동보를 임시적으로 방류하였는데, 하류측의 안전을 확인하지 않고 관행적으로 가동보를 방류하였고, 경보시스템의 부재로 인하여 가동보 하류측 징검다리를 건너는 유치원생들이 급류에 휩쓸리는 사고가 발생하였고, 최근 2014년 5월에는 수원시에 위치한 원천저수지 여수로 둑에 설치된 가로 34m 높이 1.6m 크기의 가동보가 공기압축기의 오작동으로 인하여 보 높이가 낮아지면서 약 30분 원천저수지 하류의 원천리천에 갑자기 무리 불어나 산책로가 침수되고 인근에 산책하던 주민들이 휩쓸려 떠내려가는 사고가 발생하였다. 해외에서도 가동보 운영 미숙으로 인하여 인명사고가 발생하는데, 2008년 11월 호주에서는 하류측 상황 점검이나 경고 방송 없이 가동보를 도복시켜 4살 여아가 급류에 사망하는 사고가 발생하였다. 국외의 경우에는, 상류측 홍수 수위나 하류측 역류 수위를 조절하기 위하여 가동보의 높이를 제어하는 시스템을 구비하고 있지만 이러한 시스템 역시 단순한 수위조절 기능으로서 가동보의 방류량을 제어하지 못하는 실정이다. 가동보를 운영하기 위한 조작시스템은 국내의 경우, 조작실의 조작판넬을 이용하여 가동보의 기립/도복 조작이나 원격 조작 기능과 같은 단순기능만을 구비하고 있어 가동보 방류시 하류측의 범람 피해를 야기하고 있다. 본 연구에서는 가동보 방류에 의한 하류측 범람 피해를 최소화하기 위하여 (1) 가동보 도복에 의한 방류량 산정 알고리즘을 개발하고, (2) 방류량에 따른 하류측 수위상승 범위 예측 기법을 개발하고, (3) 가동보 도복 속도를 제어하는 방류량 제어시스템을 개발하고, (4) 가동보 방류에 의한 비상경보시스템을 개발하였다.

  • PDF

Development of Operation Control and Warning System of Movable Weir for River Safety Management (안전한 하천관리를 위한 가동보 방류제어 및 경보 시스템 개발)

  • Kim, Phil Shik;Kwon, Hyung Joong;Lee, Jae Hyouk;Park, Hyun Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.245-245
    • /
    • 2017
  • 하천 시설물은 홍수시 혹은 비상시 운영할 수 있는 경보시스템이나 관리지침 등의 마련이 필수적임에도 불구하고, 현재까지 가동보 시설물에 대한 비상시 운영 메뉴얼 및 경보시스템이 구축되지 못한 실정이다. 4대강 살리기 사업이나 하천정비사업과 같은 대표적인 하천관련 사업에서 단순한 하천 이 치수 목적뿐만 아니라 소수력 발전, 친수공간조성 등의 다목적 활용을 위하여 가동보 설치 사업이 다수 수행되었으며, 현재 국내 하천에 약 1,200여개의 가동보가 설치 운영되고 있다. 이와 같이 다목적 활용을 위하여 가동보의 수요가 급증하는데 반해, 각 설치 현장 상황에 적합한 가동보 운영지침이나 비상경보시스템이 구축되지 못한 실정이며, 적절한 지침 없이 관행적인 가동보 방류로 인한 물놀이 안전사고나 인명피해가 속출하고 있는 실정이다. 2012년 11월에는 하천 제수변 공사를 위해 전주천에 설치한 가동보를 임시적으로 방류하였는데, 하류측의 안전을 확인하지 않고 관행적으로 가동보를 방류하였고, 경보시스템의 부재로 인하여 가동보 하류측 징검다리를 건너는 유치원생들이 급류에 휩쓸리는 사고가 발생하였고, 최근 2014년 5월에는 수원시에 위치한 원천저수지 여수로 둑에 설치된 가로 34m 높이 1.6m 크기의 가동보가 공기압축기의 오작동으로 인하여 보 높이가 낮아지면서 약 30분 원천저수지 하류의 원천리천에 갑자기 무리 불어나 산책로가 침수되고 인근에 산책하던 주민들이 휩쓸려 떠내려가는 사고가 발생하였다. 해외에서도 가동보 운영 미숙으로 인하여 인명사고가 발생하는데, 2008년 11월 호주에서는 하류측 상황 점검이나 경고 방송 없이 가동보를 도복시켜 4살 여아가 급류에 사망하는 사고가 발생하였다. 국외의 경우에는, 상류측 홍수 수위나 하류측 역류 수위를 조절하기 위하여 가동보의 높이를 제어하는 시스템을 구비하고 있지만 이러한 시스템 역시 단순한 수위조절 기능으로서 가동보의 방류량을 제어하지 못하는 실정이다. 가동보를 운영하기 위한 조작시스템은 국내의 경우, 조작실의 조작판넬을 이용하여 가동보의 기립/도복 조작이나 원격 조작 기능과 같은 단순기능만을 구비하고 있어 가동보 방류시 하류측의 범람 피해를 야기하고 있다. 본 연구에서는 가동보 방류에 의한 하류측 범람 피해를 최소화하기 위하여 (1)가동보 도복에 의한 방류량 산정 알고리즘을 개발하고, (2) 방류량에 따른 하류측 수위상승 범위 예측 기법을 개발하고, (3) 가동보 도복 속도를 제어하는 방류량 제어시스템을 개발하고, (4) 가동보 방류에 의한 비상경보시스템을 개발하였다.

  • PDF