• 제목/요약/키워드: 친환경 공동주택

검색결과 99건 처리시간 0.026초

친환경 공동주택 구현을 위한 저에너지 설비시스템 통합설계 방안 및 파일럿 프로젝트 계획 (A Pilot Project on the Integrated System Design for Developing the Sustainable Housing Model)

  • 조진균;성재호;신선준;홍민호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1049-1054
    • /
    • 2009
  • Sustainable housing design can contribute to dramatically reduced energy usage and can be applied to all new building projects. This paper explores the potential in Korea of applying available energy efficient building technologies. The objective was to determine the degree of energy reduction that can easily be achieved in new building design. The pilot project is providing some prototypes with display units which incorporate principles of sustainable design and performance utilizing the eco-design objectives. This building challenges ingrained preconceptions about system designs for four energy saving levels(40%, 60%, 80% and zero energy) and exposes barriers to low energy buildings posed by new standards and guidelines.

  • PDF

국내외 친환경 건축물 인증제도의 변천과정 고찰을 통한 G-SEED의 평가 체계 개선방안 연구 - 공동주택을 중심으로 - (A Study on Problems and Improvement for G-SEED of Evaluation System through Investigating Transition Process of Overseas Green Building Certification Criterion - Focused on Apartment -)

  • 박재한;차기욱;홍원화
    • 한국주거학회논문집
    • /
    • 제24권5호
    • /
    • pp.69-76
    • /
    • 2013
  • The seriousness of greenhouse gas exhaustions and energy use of the building has increased, the world is making an effort with many requests and the consultation for sustainable development. For this reason, Green Building Certification Criteria has been implemented to reduce environmental load, high-performance and environmentally friendly in the United States, the United Kingdom and Germany. In response to the global trend like this, the Korean Government has induced the eco-friendly construction and sustainable development to implement the G-SEED (Green Building Certification Criteria of Korea) in 2002. However, in spite of the many authentication result, G-SEED has been pointed out that it needs for improve in the evaluation system of Apartment sector which accounts for more than 40% of the authentication. Therefore, the purpose of this study is to suggest improvements in the evaluation system. To achieve this, this study have selected for LEED, BREEAM, DGNB of comparison target, drawn improvements through comparing transition process in G-SEED.

독일 공동주택 놀이터의 친환경적 특성 연구 (A Study on the Eco-friendly Properties of Apartment Housing Playground in Germany)

  • 김자경
    • 한국실내디자인학회논문집
    • /
    • 제24권5호
    • /
    • pp.87-98
    • /
    • 2015
  • As an apartment house as well as improving quality of life is becoming one of the brands, it is increasing the importance of the outer space with the facilities in the housing complex. In particular, the outdoor playground such as the community facilities that children and adults share as the activity areas for residents has received attention. However, actually children have not used many of Korean apartment housing playgrounds that were installed formally in the scrap area according to the housing plan by residential construction standards. it is considered necessary to improve the quality of the playground in housing complex and reform it in order to make the eco-friendly play space in which children can play safely and h healthily. As an alternative, we analyzed the eco-friendly properties of the playgrounds installed in the eco-friendly housing complex in Germany and derived the main planning elements of eco-friendly playground. In the observational survey of the 10 playgrounds in 9 housing complexes in 5 regions in Germany, we evaluated the environment-friendliness of these playgrounds in the 8 fields(location and placement, ecological environment, play space, play equipment and facilities, additional facilities, materials and resources, energy saving, environmental load reduction) according to the levels(suitable, partial reflection, unsuitable, non-reflection) of reflection of eco-friendly planning factors. The following is the summary of the results about the reflection of eco-friendly planning factors. In terms of "suitable": location and placement(88.8%), play equipment and facilities(73.5%), additional facilities(60.6%), environmental load reduction(54%), and ecological environment(50%) were higher than others. In terms of "unsuitable": there was nothing. In terms of "non-reflection": energy saving(95%), additional facilities(32.2%), and materials and resources(30.9%) were in order. Therefore, on the basis of these results, this study proposed the planning indicators to be considered first and the planning factors that should be complemented and improved in the construction of apartment housing playground in future.

공동주택 친환경 리모델링을 위한 구성재 접합부 실태조사 연구 (A Study on the Component joint for the Environment -Friendly Apartment Remodeling)

  • 임석호
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 2005
  • Recently, Domestic construction industry is confronted with a new phase by increasement of stock and elation of the concern about environment. In particular, the focus on remodeling as an altanative of the reconstruction system that squanders resources and creates massive construction waste, has increased. However, current remodeling methods are being obstructed factor, because design has not considered the remodeling at the beginning of the construction. The purpose of this study is to search for the improvement of component joint for efficient remodeling. Field survey is conducted on the components grouped by spaces(living room/bed room/kitchen/bathroom) of unit living at 6 construction sites in Seoul & countries. As a result, total 228 component joints are selected and classified according to interface condition and problem pattern.

  • PDF

국내 친환경 건축물 인증제도 평가항목의 중요도 분석 - 공동주택 인증심사기준 중심으로 - (Analyzing the Weight of Assessment Criteria in Korea Green Building Certification System - Focused on Certification Standards for Multi-unit Apartment Projects -)

  • 최여진;이상춘
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.83-90
    • /
    • 2012
  • Over the world, social demands and concerns of energy and resource depletions and environmental conservation have resulted in many researches and applications on sustainable development and construction. In order to support these demands and concerns, international green building certification systems such as LEED(Leadership in Energy and Environmental Design) and BREEAM(Building Research Establishment Environmental Assessment Method) were developed. In Korea, the green building certification system was introduced in 2000 and widely applied to all types of new buildings in order to induce the diffusion of sustainable buildings on May, 2010. This paper investigates the importance of assessment criteria on multi-unit apartment projects among certification rating systems using the AHP(Analytic Hierarchy Process) method and suggests a new direction on certification assessment standards. For applying the AHP method, the survey of staffs in green building certification consulting companies and architectural design companies was conducted via e-mail. As a result, criteria like energy, indoor environment, land use, pollution control, and ecological environment among 9 main ones turned out important on assessing green building certification at multi-unit apartment projects, while criteria like water resource, transportation, maintenance management, and material and resource did relatively unimportant.

진동측정을 통한 공동주택 엘리베이터 소음 레벨 평가 (Evaluation of Elevator Noise level of Apartment Houses through Vibration Measurement)

  • 강민우;송민정;오양기
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.641-654
    • /
    • 2018
  • Elevator noise in apartment houses is one of the factors which prevent the residents from quiet and comfortable life. The elevator noise measurement method [KS F ISO 16032] is introduced from the matching ISO standard, however, it has problems in the application to the actual measurement. To visualize the problems, measurements in an apartment house are conducted, which has been suffering from the elevator noise for a long time. The measurement itself is extremely difficult due to the low sound pressure level of elevator, which is lower than 35 dB (A), and the even higher background noise level. However the vibration levels measured at the same time are relatively less disturbing As a result of vibration measurement, it was found that the vibration is clearly measured on the wall, and presents a high correlation coefficient of over 0.8 with the noise levels measured This shows that the vibration level measured on the elevator walls may be rather reliable numbers than the elevator noise levels in the actual noisy condition of elevator halls and the vicinity.