• Title/Summary/Keyword: 치주인대

Search Result 4,599, Processing Time 0.031 seconds

Three Dimensional Skeletal, Dentoalveolar and Airway Space Changes after Slow Maxillary Expansion in Children (어린이에서 저속 상악 확장에 따른 골격성, 치아치조성, 기도 변화에 대한 3차원적 평가)

  • Nawoon Kim;Daewoo Lee;Jae-Gon Kim;Yeonmi Yang
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.155-167
    • /
    • 2023
  • The aim of this study was to investigate the effects of slow maxillary expansion (SME) on the dentoalveolar, skeletal, upper airway, and maxillary sinus using cone-beam computed tomography (CBCT). Twenty-three orthodontic patients (mean age 8.93 ± 1.61 years) who were treated with maxillary expansion using banded hyrax in the Department of Pediatric Dentistry at Jeonbuk National University Dental Hospital were included. According to the expansion speed applied, they were divided into two groups: SME (12 subjects, mean age 8.92 ± 1.45 years) and rapid maxillary expansion (RME, 11 subjects, mean age 8.94 ± 1.84 years). CBCT were obtained before (T0) and after (T1) the treatment and were analyzed with InVivo5 software (Anatomage, San Jose, CA, USA). Descriptive statistics showed no significant differences between the two groups in age, sex, or skeletal maturity. There were significant increases in maxillary width at the dentoalveolar and skeletal levels for both groups. Upper airway volume revealed a significant increase of 38.59% in the SME group and 28.72% in the RME group. However, there was no significant difference between SME group and RME group in all measurements. This study suggested the efficacy of SME in growing patients. SME was effective in increasing not only dentoalveolar and skeletal measurements but also airway volume. Therefore, pediatric dentists should select an appropriate expansion method considering the physiological aspects of periodontal tissues and discomfort in growing children.

Evaluation of the clinical and radiographic effectiveness of treating peri-implant bone defects with a new biphasic calcium phosphate bone graft: a prospective, multicenter randomized controlled trial

  • Jae-Hong Lee;Hyun-wook An;Jae-Seung Im;Woo-Joo Kim;Dong-Won Lee ;Jeong-Ho Yun
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.4
    • /
    • pp.306-317
    • /
    • 2023
  • Purpose: Biphasic calcium phosphate (BCP), a widely used biomaterial for bone regeneration, contains synthetic hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP), the ratio of which can be adjusted to modulate the rate of degradation. The aim of this study was to evaluate the clinical and radiographic benefits of reconstructing peri-implant bone defects with a newly developed BCP consisting of 60% β-TCP and 40% HA compared to demineralized bovine bone mineral (DBBM). Methods: This prospective, multicenter, parallel, single-blind randomized controlled trial was conducted at the periodontology departments of 3 different dental hospitals. Changes in clinical (defect width and height) and radiographic (augmented horizontal bone thickness) parameters were measured between implant surgery with guided bone regeneration (GBR) and re-entry surgery. Postoperative discomfort (severity and duration of pain and swelling) and early soft-tissue wound healing (dehiscence and inflammation) were also assessed. Data were compared between the BCP (test) and DBBM (control) groups using the independent t-test and the χ2 test. Results: Of the 53 cases included, 27 were in the test group and 26 were in the control group. After a healing period of 18 weeks, the full and mean resolution of buccal dehiscence defects were 59.3% (n=16) and 71.3% in the test group and 42.3% (n=11) and 57.9% in the control group, respectively. There were no significant differences between the groups in terms of the change in mean horizontal bone augmentation (test group: -0.50±0.66 mm vs. control groups: -0.66±0.83 mm, P=0.133), postoperative discomfort, or early wound healing. No adverse or fatal complications occurred in either group. Conclusions: The GBR procedure with the newly developed BCP showed favorable clinical, radiographic, postoperative discomfort-related, and early wound healing outcomes for peri-implant dehiscence defects that were similar to those for DBBM.

Repeated irradiation by light-emitting diodes may impede the spontaneous progression of experimental periodontitis: a preclinical study

  • Hyemee Suh;Jungwon Lee;Sun-Hee Ahn;Woosub Song;Ling Li;Yong-Moo Lee;Yang-Jo Seol;Ki-Tae Koo
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.120-134
    • /
    • 2023
  • Purpose: We investigated whether repeated irradiation with light-emitting diodes (LEDs) at a combination of 470 nm and 525 nm could suppress the progression of experimental periodontitis. Methods: A experimental periodontitis model was established in the second, third, and fourth premolars of the mandible in beagle dogs for 2 months. The spontaneous progression of periodontitis was monitored under the specified treatment regimen for 3 months. During this period, the animals were subjected to treatments of either plaque control only (control) or plaque control with LED application (test) at 2-week intervals. The clinical parameters included the probing pocket depth (PPD), gingival recession (GR), and the clinical attachment level (CAL). Histomorphometric analysis was performed using measurements of the length of the junctional epithelium, connective tissue (CT) zone, and total soft tissue (ST). Results: There were significant differences in PPD between the control and test groups at baseline and 12 weeks. When the change in PPD was stratified based on time intervals, it was shown that greater differences occurred in the test group, with statistical significance for baseline to 12 weeks, 6 to 12 weeks, and baseline to 6 weeks. There was no significant difference in GR between the control and test groups at any time points. Likewise, no statistically significant differences were found in GR at any time intervals. CAL showed a statistically significant difference between the control and test groups at baseline only, although significant differences in CAL were observed between baseline and 12 weeks and between 6 and 12 weeks. The proportion of CT to ST was smaller for both buccal and lingual areas in the control group than in the test group. Conclusions: Repeated LED irradiation with a combination of 470-nm and 525-nm wavelengths may help suppress the progression of periodontal disease.

The impact of polydeoxyribonucleotide on early bone formation in lateral-window sinus floor elevation with simultaneous implant placement

  • Dongseob Lee;Jungwon Lee;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.157-169
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate the impact of polydeoxyribonucleotide (PDRN) on histologic outcomes when implant placement and lateral sinus floor elevation are performed simultaneously. Methods: Three bimaxillary premolars (P2, P3, and P4) were extracted from 4 beagle dogs 2 months before lateral sinus floor elevation. After lateral elevation of the sinus membrane, each sinus was allocated to either the test or control group. Sinuses underwent either 1) collagenated synthetic bone graft with PDRN following lateral sinus floor elevation (test group) or 2) collagenated synthetic bone graft without PDRN after lateral sinus floor elevation (control group). Eight weeks after the surgical procedure, all animals were euthanised for a histologic and histomorphometric assessment. Augmented height (AH), protruding height (PH), and bone-to-implant contact in pristine (BICp) and augmented (BICa) bone were measured. The composition of the augmented area, which was divided into 3 areas of interest located in coronal, middle and apical areas (AOI_C, AOI_M, and AOI_A), was calculated with 3 parameters: the area percentage of new bone (pNB), residual bone graft particle (pRBP), and fibrovascular connective tissue (pFVT). Results: AH, PH, BICp, BICa total, BICa coronal, and BICa middle values were not significantly different between sinuses in the control and test groups (all P>0.05). The BICa apical of sinuses in the test group (76.7%±9.3%) showed statistically higher values than those of sinuses in the control group (55.6%±22.1%) (P=0.038). pNB, pRBP, and pFVT showed statistically significant differences between the 2 groups in AOI_A (P=0.038, P=0.028, and P=0.007, respectively). pNB, pRBP, and pFVT in AOI_C and AOI_M were not significantly different between samples in the control and test groups (all P>0.05). Conclusions: The histologic findings revealed that lateral sinus floor elevation with PDRN might improve early new bone formation and enable higher bone-to-implant contact.

The oral microbiome of implant-abutment screw holes compared with the peri-implant sulcus and natural supragingival plaque in healthy individuals

  • MinKee Son;Yuri Song;Yeuni Yu;Si Yeong Kim;Jung-Bo Huh;Eun-Bin Bae;Won-Tak Cho;Hee Sam Na;Jin Chung
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.3
    • /
    • pp.233-244
    • /
    • 2023
  • Purpose: An implant-supported prosthesis consists of an implant fixture, an abutment, an internal screw that connects the abutment to the implant fixture, and the upper prosthesis. Numerous studies have investigated the microorganisms present on the implant surface, surrounding tissues, and the subgingival microflora associated with peri-implantitis. However, there is limited information regarding the microbiome within the internal screw space. In this study, microbial samples were collected from the supragingival surfaces of natural teeth, the peri-implant sulcus, and the implant-abutment screw hole, in order to characterize the microbiome of the internal screw space in healthy subjects. Methods: Samples were obtained from the supragingival region of natural teeth, the peri-implant sulcus, and the implant screw hole in 20 healthy subjects. DNA was extracted, and the V3-V4 region of the 16S ribosomal RNA was sequenced for microbiome analysis. Alpha diversity, beta diversity, linear discriminant analysis effect size (LEfSe), and network analysis were employed to compare the characteristics of the microbiomes. Results: We observed significant differences in beta diversity among the samples. Upon analyzing the significant taxa using LEfSe, the microbial composition of the implant-abutment screw hole's microbiome was found to be similar to that of the other sampling sites' microbiomes. Moreover, the microbiome network analysis revealed a unique network complexity in samples obtained from the implant screw hole compared to those from the other sampling sites. Conclusions: The bacterial composition of the biofilm collected from the implant-abutment screw hole exhibited significant differences compared to the supra-structure of the implant. Therefore, long-term monitoring and management of not only the peri-implant tissue but also the implant screw are necessary.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Adjunctive effect of 470-nm and 630-nm light-emitting diode irradiation in experimental periodontitis treatment: a preclinical study

  • Dongseob Lee;Jungwon Lee;Sun-Hee Ahn;Woosub Song;Ling Li;Yang-Jo Seol;Yong-Moo Lee;Ki-Tae Koo
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.13-24
    • /
    • 2024
  • Purpose: This study investigated the adjunctive effect of light-emitting diodes (LEDs) in the treatment of experimental periodontitis. Methods: Experimental periodontitis was induced by placing ligatures around the mandibular second, third, and fourth premolars of 6 beagles for 3 months. After ligature removal, periodontitis progressed spontaneously for 2 months. The animals' hemimandibles were allocated among the following 3 groups: 1) no treatment (control), 2) scaling and root planing (SRP), and 3) SRP with LED irradiation at 470-nm and 630-nm wavelengths (SRP/LED). The probing pocket depth (PPD) and gingival recession (GR) were measured at baseline, 6 weeks, and 12 weeks. The clinical attachment level (CAL) was calculated. After 12 weeks, histological and histomorphometric assessments were performed. The distances from the gingival margin to the apical extent of the junctional epithelium (E) and to the connective tissue (CT) attachment were measured, as was the total length of soft tissue (ST). Results: PPD and CAL increased at 12 weeks compared with baseline in the control group (6.31±0.43 mm to 6.93±0.50 mm, and 6.46±0.60 mm to 7.61±0.78 mm, respectively). PPD and CAL decreased at 12 weeks compared with baseline in the SRP group (6.01±0.59 to 4.81±0.65 mm, and 6.51±0.98 to 5.39±0.93 mm, respectively). PPD and CAL decreased at 12 weeks compared with baseline in the SRP/LED group (6.03±0.39 to 4.46±0.47 mm, and 6.11±0.47 to 4.78±0.57 mm, respectively). The E/ST and CT/ST ratios significantly differed among the 3 groups (P<0.05). The clinical parameters and histologic findings demonstrated that 470-nm and 630-nm wavelength LED irradiation accompanying SRP could improve treatment results. Conclusions: Within the study limitations, 470 nm and 630 nm wavelength LED irradiation might provide additional benefits for periodontitis treatment.

The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study

  • Dong-Hui Nam;Pil-Jong Kim;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee;Young Ku;In-Chul Rhyu;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.53-62
    • /
    • 2024
  • Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external-and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.

Impact of COVID-19 spread on visit intervals and clinical parameters for patients with periodontitis in supportive periodontal therapy: a retrospective study

  • Mizuho Yamazaki-Takai;Yumi Saito;Shoichi Ito;Moe Ogihara-Takeda;Tsuyoshi Katsumata;Ryo Kobayashi;Shuta Nakagawa;Tomoko Nishino;Namiko Fukuoka;Kota Hosono;Mai Yamasaki;Yosuke Yamazaki;Yuto Tsuruya;Arisa Yamaguchi;Yorimasa Ogata
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.75-84
    • /
    • 2024
  • Purpose: This study investigated the relationship between the number of days that hospital visits were postponed and changes in clinical parameters due to the spread of coronavirus disease 2019 (COVID-19), after the Japanese government declared a state of emergency in April 2020. Methods: Regarding the status of postponement of appointments, we analyzed the patients who had visited the Nihon University Hospital at Matsudo for more than 1 year for supportive periodontal therapy (SPT) and classified them into low-, moderate- and high-risk subgroups according to the periodontal risk assessment (PRA). Clinical parameters for periodontal disease such as probing depth (PD), full-mouth bleeding score (FMBS), full-mouth plaque score, periodontal inflamed surface area (PISA), and periodontal epithelial surface area (PESA) were analyzed in 2 periods, from October 2019 to March 2020 and after April 2020. Correlation coefficients between days of deferral and the degree of changes in clinical parameters were calculated. Results: The mean age of the 749 patients was 67.56±10.85 years, and 63.82% were female. Out of 749 patients, 33.24% deferred their SPT appointments after April 2020. The average total of postponement days was 109.49±88.84. The number of postponement days was positively correlated with changes in average PD (rs=0.474) and PESA (rs=0.443) in the high-risk subgroup of FMBS, and average PD (rs=0.293) and PESA (rs=0.253) in the highrisk subgroup of tooth number (TN). Patients belonging to the high-risk subgroups for both FMBS and TN had a positive correlation between postponement days and PISA (rs=0.56). Conclusions: The findings, the spread of COVID-19 appears to have extended the visit interval for some SPT patients. Moreover, longer visit intervals were correlated with the worsening of some clinical parameters for SPT patients with high PRA.

Comparative analysis of the in vivo kinetic properties of various bone substitutes filled into a peri-implant canine defect model

  • Jingyang Kang;Masaki Shibasaki;Masahiko Terauchi;Narumi Oshibe;Katsuya Hyodo;Eriko Marukawa
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.96-107
    • /
    • 2024
  • Purpose: Deproteinized bovine bone or synthetic hydroxyapatite are 2 prevalent bone grafting materials used in the clinical treatment of peri-implant bone defects. However, the differences in bone formation among these materials remain unclear. This study evaluated osteogenesis kinetics in peri-implant defects using 2 types of deproteinized bovine bone (Bio-Oss® and Bio-Oss/Collagen®) and 2 types of synthetic hydroxyapatite (Apaceram-AX® and Refit®). We considered factors including newly generated bone volume; bone, osteoid, and material occupancy; and bone-to-implant contact. Methods: A beagle model with a mandibular defect was created by extracting the bilateral mandibular third and fourth premolars. Simultaneously, an implant was inserted into the defect, and the space between the implant and the surrounding bone walls was filled with Bio-Oss, Bio-Oss/Collagen, Apaceram-AX, Refit, or autologous bone. Micro-computed tomography and histological analyses were conducted at 3 and 6 months postoperatively (Refit and autologous bone were not included at the 6-month time point due to their rapid absorption). Results: All materials demonstrated excellent biocompatibility and osteoconductivity. At 3 months, Bio-Oss and Apaceram-AX exhibited significantly greater volumes of formation than the other materials, with Bio-Oss having a marginally higher amount. However, this outcome was reversed at 6 months, with no significant difference between the 2 materials at either time point. Apaceram-AX displayed notably slower bioresorption and the largest quantity of residual material at both time points. In contrast, Refit had significantly greater bioresorption, with complete resorption and rapid maturation involving cortical bone formation at the crest at 3 months, Refit demonstrated the highest mineralized tissue and osteoid occupancy after 3 months, albeit without statistical significance. Conclusions: Overall, the materials demonstrated varying post-implantation behaviors in vivo. Thus, in a clinical setting, both the properties of these materials and the specific conditions of the defects needing reinforcement should be considered to identify the most suitable material.