• Title/Summary/Keyword: 치아 길이

Search Result 146, Processing Time 0.027 seconds

Full mouth rehabilitation of a patient with severe tooth erosion with a digital crown lengthening guide (심한 부식 환자의 디지털 치관연장술 가이드를 이용한 전악 수복 증례)

  • Park, Yunjae;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.280-287
    • /
    • 2019
  • In the oral cavity, the teeth undergo wear and corrosion throughout their lives. Progressive and constant tooth wear is a natural phenomenon of aging, but wear and corrosion due to specific factors are pathological factors. It can cause pathological damage of the occlusal surface, aesthetic problems, dimensional loss and jaw joint disorders. This case is a 26-year-old female patient with general tooth abrasion and erosion on the entire dentition. Diagnostic wax-up was fabricated based on the information including digital facial analysis, physiological stabilization, and evaluation of anterior crown length. Through the digital analysis, the necessary guides for crown lengthening were prepared and the mastication function and esthetics were evaluated by using temporary crowns. Definitive prosthesis was fabricated with the zirconia restorations. The results were satisfactory when they were observed 3 months of follow-up.

Thermomechanical Effect on the Water Wet Dental Hard Tissue by the Q-switched Er : YAG Laser

  • Y. H. Kwon;Ky0-han Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.231-236
    • /
    • 1999
  • Understanding the exgenous water induced thermomechanical effect on the dental hard tissue by the Q-switched Er:YAG laser (1-$mutextrm{s}$-long pulse width) has an important impact on the further understanding of the free-running Er:YAG laser (250-$mutextrm{s}$-long pulse width) ablation on the dental gard tissue because one macroscopic effect in the free-running laser is an accumulation of microscopic effects we investigated in this study. The Q-switched Er:YAG laser with exogenous water on the tooth enhanced ablation rate compared to the case of no water on the tooth. The frequency of exogenous-water jet on the tooth has affected the ablation rate in such a way that as we dispensed water drops less frequently we could get more enhanced ablation rate. The amplitude of the recoil pressure depends on the tooth surface conditions such that as surfaces wet, and as the volume of the exogenous water drop increased, the amplitude of the recoil pressure increased also. From this study we realized that the 1 $mutextrm{s}$ long pulsed induced thermomechanical effect provides us useful information for the understanding of the free-running Er:YAG laser induced ablation with exogenous water.

  • PDF

The accuracy evaluation of digital surgical stents according to supported type (디지털 수술용 가이드의 지지타입에 따른 정확도 평가)

  • Lee, Junyoun;Yoon, Minho;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.8-16
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. Materials and methods: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. Results: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. Conclusion: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.

The fluoride application using low frequency non-thermal plasma jet

  • Lee, Hyeon-Yeong;Dang, Cheon-U;Kim, Yeong-Min;Kim, Dong-Hyeon;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.228.1-228.1
    • /
    • 2016
  • 기존 산업에서 많이 쓰여져오고 있는 저압 플라즈마에 비해 여러가지 장점을 지닌 대기압 플라즈마는 수년 전부터 많은 연구가 되어 왔으며 폭넓은 응용분야에 있어서 활발히 이용되고 있고, 특히 온도가 거의 상온과 비슷하다는 장점으로 대기압 저온 플라즈마는 바이오메디컬 분야에서 활발하게 응용되어지고 있다. 본 연구에서는 대기압 저온 플라즈마 젯 장치를 사용하여 치아 표면에 불소를 도포하고 법랑질 표면의 불소 원소를 검출함으로써 플라즈마가 치아표면 불소도포에 있어서 어떠한 효과가 있는지 정량적으로 비교분석하였다. 또한 대기압 플라즈마 젯 장치의 방전개시전압과 가스유량에 따른 플라즈마젯 길이의 변화 및 OES(Optical Emission Spectroscopy) 장치를 사용하여 플라즈마에 대한 광학적 진단을 진행하였다. 치아표면에서 검출된 불소량은 플라즈마를 사용했을때가 그렇지 않을때에 비해 더 높게 관찰 되었다.

  • PDF

Finite element analysis of effectiveness of lever arm in lingual sliding mechanics (Lingual sliding mechanics의 lever arm 효과에 대한 유한요소분석)

  • Kim, Kyeong-Hee;Lee, Kee-Joon;Cha, Jung-Yul;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.324-336
    • /
    • 2011
  • Objective: The aim of this study was to conduct three-dimensional finite element analysis of individual tooth displacement and stress distribution when a posterior retraction force of 200 g was applied at different positions of the retraction hook on the transpalatal arch (TPA) of a molar, and over different lengths of the lever arm on the maxillary anterior teeth in lingual orthodontics. Methods: A three-dimensional finite element model, including the entire upper dentition, periodontal ligaments, and alveolar bones, was constructed on the basis of a sample (Nissan Dental Product, Kyoto, Japan) survey of Asian adults. Individual movement of the incisal edge and root apex was estimated along the x-, y-, and z-coordinates to analyze tooth displacement and von Mises stress distribution. Results: When the length of the lever arm was 15 mm and 20 mm, the incisal edge and root apex of the anterior teeth was displaced lingually, with a maximum lingual displacement at the lever arm length of 20 mm. When the posterior retraction hook was on the root apex, the molars showed distal displacement. When the length of the lever arm was 20 mm, anterior extrusion was reduced and the crown of the canine displaced toward the buccal side, in which case, the retraction hook was on the edge, rather than at the center, of the TPA. Conclusions: The results of the analysis showed that when 6 anterior teeth were retracted posteriorly, lateral displacement of the canine and lingual displacement of the incisal edge and root apex of the anterior teeth occur without the extrusion of the anterior segment when the length of the lever arm is longer, and the posterior retraction hook is in the midpalatal area.

PHYSIOLOGIC ERUPTION INDUCTION OF TRANSPOSED IMPACTED UPPER INCISORS THROUGH AUTOTRANSPLANTATION (변위매복된 상악전치의 자가이식을 통한 자발적 맹출 유도)

  • Kim, Jae-Gon;Lee, Doo-Cheol;Oh, Kyong-Seon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.281-286
    • /
    • 2001
  • The treatment method of impacted tooth is various from simple observation to surgical exposure and orthodontic methods, autotransplantation is concerned to severe malposed impacted tooth. Autotransplantation is the transplantation of embedded, impacted, of unerupted tooth, into extraction socket of surgically prepared in the same individual. Autotransplantation of tooth with $\frac{1}{2}{\sim}\frac{3}{4}$ root development provides a good chance of easily extracted, a little complication, pulp survival, and complete root formation. Transplantation of uncompleted root apex tooth is aim to pulpal healing, not endodontic treatment. The case which were treated with autotransplantation is reported, and induced normal physiologic eruption and good dental alignment.

  • PDF

TREATMENT OF ANTERIOR TEETH FRACTURE BY FORCED ERUPTION (치아 정출술을 이용한 전치부 외상치의 치험례)

  • Kim, Ji-Young;Choi, Nam-Ki;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.575-582
    • /
    • 2001
  • There have been many treatment methods for traumatic subgingival crown fracture and intrusion without spontaneous eruption. The orthodontic forced eruption generally results in favorable clinical findings than crown lengthening with osteotomy and intentional replantation. In first two cases with subgingival crown fracture due to trauma, authors applied orthodontic forced eruption with axed appliance after root canal therapy and then restored them with composite resin. In another case with traumatic intrusive luxation, we observed spontaneous eruption of the corresponding tooth for about 6 months and then returning it to normal position by forced eruption with removable appliance, but root canal filling was conducted after apexification due to devitalization during forced eruption, and so clinically favorable results were obtained.

  • PDF

A retrospective study on survival rates of dental implants in elderly patients (노인 환자에서 임플란트의 생존율에 대한 후향적 연구)

  • Shin, Hee-Jong;Yu, Sang-Joun;Kim, Byung-Ock
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.326-347
    • /
    • 2015
  • 목적: 노인 환자에서 식립된 임플란트의 생존율을 조사하고 다양한 요인에 따라 생존율에 미치는 영향을 후향적으로 평가하고자 하였다. 재료 및 방법: 2001년 1월부터 2007년 12월까지 조선대학교 치과병원 치주과에 내원한 65세 이상 노인 환자 56명에게 식립된 138개의 임플란트를 대상으로 하였다.(남자 38명, 여자 18명, 평균 연령$69.38{\pm}3.91$세) 임플란트 생존율은 환자 성별 및 연령, 전신질환 유무, 치아 상실 원인, 식립 위치, 임플란트 직경 및 길이, 골질, 골이식 여부, 상부 보철물 유형에 따라 조사되었다. Kaplan-Meier survival analysis을 통해 각 요인에 따른 누적 생존율을 조사하였고, chi-square test를 통해 누적 생존율과 각각의 요인 간의 통계학적 유의성을 평가하였다. 결과: 보철물 시적 후 5 ~ 140개월 간 추적 관찰을 시행하였다. 65세 이상 노인 환자 56명에게 식립된 총 138개의 임플란트 중 추적 관찰 기간 동안 5개의 임플란트가 실패하였다. 그 중 63개의 임플란트는 환자가 정기적인 내원 약속에 응하지 않아 도중에 조사대상에서 제외되었으며, 결과적으로 5년간 누적 생존율은 94.9%였다. 임플란트 생존율에 영향을 미치는 다양한 요인 중 골질 (P=0.037) 및 상부 보철물 유형 (P=0.015) 간에 누적 생존율이 통계적으로 유의한 차이가 있었다. 그외 연령, 성별, 전신질환 유무, 치아상실 원인, 식립 위치, 임플란트 직경 및 길이, 골이식 유무 관련 요인과 누적 생존율 사이에는 통계적으로 유의한 차이가 없었다. 결론: 여러 한계가 있었지만 노인 환자의 무치악 부위에 있어 임플란트는 장기간에 걸쳐 예지성 있고 받아들여질 만한 치료이면서 적은 합병증과 실패율을 가진다.

Study on accuracy of panorama and CBCT through length measurement of wisdom teeth (사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Panorama of dental radiation generators can observe the wide anatomical structures of oral and maxillofacial areas but there can be distortion of lengths, angles, or shapes. CBCT can diagnose 3D images and get the ones whose errors by superposition and interference are remarkably smaller between anatomical structures. But the quality of the images by movement of subjects can be lowered as it takes long to diagnose them. And if there are impermeable radiation objects like metal in mouths, impermeable radiation lines can radially appear with the objects as center. This study tries to analyze accuracy of panorama and CBCT and get useful anatomical information in dental treatment by comparing the length of wisdom teeth which were measured by Panorama and CBCT with the teeth which were actually extracted and analyzing distortion of the teeth. The test result could be found that Panorama is expanded by average 7.3% as the errors of Panorama and Digital Vernier Caliper range from 110.7% to 103.9%. The length of wisdom teeth which were measured in CBCT and Digital Vernier Caliper could be found that the error range is 1.3%. And the length of wisdom teeth which were measured in Panorama and Digital Vernier Caliper has found that the error range shows 7.3%. So it could be found that the images of CBCT is about 6% more exact than those of Panorama. It could be found that CBCT shows the more exact images than those of Panorama. But because the examination expenses of CBCT are higher than those of Panorama and exposure dose of CBCT is much more than that of Panorama, it is thought to find proper ways in examination.

Functional and esthetic improvement through systematic diagnosis and treatment procedures in patient with unaesthetic anterior teeth proportion because of tooth wear : A case report (마모를 동반한 비심미적인 상, 하악 전치부 비율을 가진 환자에서 체계적인 진단 및 치료과정을 통해 기능 및 심미성이 개선된 보철 수복 증례)

  • Jeong, Hae-Yong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.40-49
    • /
    • 2018
  • It is reported that the causes of unaesthetic proportion of anterior teeth vary widely. Especially, when the unaesthetic tooth proportion of the mandibular incisors arises due to the wear of the anterior teeth accompanied by the compensation of the alveolar bone, it may cause serious functional and aesthetic problems. In such case, it should be considered that the evaluation of vertical dimension and tooth proportion as well as smile line, soft tissue and hard tissue morphology. And, increase of vertical dimension or clinical crown lengthening followed by prosthodontic restorations is needed to improve the interdental mesial/distal, width/length ratio considering the anterior guidance. This case report demonstrates functional and aesthetic improvements through systematic diagnosis and treatment procedures in a 48-year-old male patient with unaesthetic anterior teeth proportion because of tooth wear accompanied by the compensation of alveolar bone and defect of several central incisors due to chronic periodontitis.