• Title/Summary/Keyword: 치아 구조

Search Result 226, Processing Time 0.026 seconds

Stress distribution of molars restored with minimal invasive and conventional technique: a 3-D finite element analysis (최소 침습적 충진 및 통상적 인레이 법으로 수복한 대구치의 응력 분포: 3-D 유한 요소 해석)

  • Yang, Sunmi;Kim, Seon-mi;Choi, Namki;Kim, Jae-hwan;Yang, Sung-Pyo;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.297-305
    • /
    • 2018
  • Purpose: This study aimed to analyze stress distribution and maximum von Mises stress generated in intracoronal restorations and in tooth structures of mandibular molars with various types of cavity designs and materials. Materials and Methods: Three-dimensional solid models of mandible molar such as O inlay cavity with composite and gold (OR-C, OG-C), MO inlay cavity with composite and gold (MR-C, MG-C), and minimal invasive cavity on occlusal and proximal surfaces (OR-M, MR-M) were designed. To simulate masticatory force, static axial load with total force of 200 N was applied on the tooth at 10 occlusal contact points. A finite element analysis was performed to predict stress distribution generated by occlusal loading. Results: Restorations with minimal cavity design generated significantly lower values of von Mises stress (OR-M model: 26.8 MPa; MR-M model: 72.7 MPa) compared to those with conventional cavity design (341.9 MPa to 397.2 MPa). In tooth structure, magnitudes of maximum von Mises stresses were similar among models with conventional design (372.8 - 412.9 MPa) and models with minimal cavity design (361.1 - 384.4 MPa). Conclusion: Minimal invasive models generated smaller maximum von Mises stresses within restorations. Within the enamel, similar maximum von Mises stresses were observed for models with minimal cavity design and those with conventional design.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF

Effect of remineralization and inhibition to demineralization after fluoride gel or hydroxyapatite paste application on stripped enamel (치간 삭제 후 불소 또는 수산화인회석 도포 시 재광화 및 탈회억제에 관한 연구)

  • Hong, Hyun-Sil;Kim, Ho-Young;Sung, Ji-Young;Cho, Jin-Hyoung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.212-226
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the effect of remineralization and inhibition to demineralization after fluoride gel (acidulated phosphate fluoride, APF) or hydroxyapatite (HAp) paste application on interdentally stripped teeth. Methods: After interdental stripping, 1.23% APF or 5%, 10% HAp paste were applied for 7 days for remineralization. Afterwards, teeth were exposed to lactate carbopol buffer solution for demineralization. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) were used to compare change in surface contents and crystal structures after remineralization, and then after demineralization. Results: EDS analysis indicated that calcium (p < 0.001) and phosphate (p < 0.01) contents were increased after 10% HAp paste application on stripped enamel, calcium (p < 0.05) and phosphate (p < 0.01) contents were increased after 5% HAp paste application, and fluoride (p < 0.01) contents were increased after 1.23% APF application. SEM image showed that enamel surfaces became smoother and crystal structures became small and compact after APF or HAp application. After demineralization, calcium (p < 0.05) and phosphate (p < 0.05) contents remained increased on the enamel remineralized with 10% HAp paste, and phosphate (p < 0.05) contents remained increased on the enamel remineralized with 5% HAp paste. After demineralization, surfaces looked less destroyed in the enamel remineralized beforehand than those of the control, and small pores between crystal structures, formed by remineralization were remained. Conclusions: Hydroxyapatite paste and fluoride gel were helpful to remineralize and inhibit deminerlization on stripped enamel.

3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays (3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets)

  • Anusree P.Sunilkumar;Seong Yong Moon;Wonsang You
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.326-334
    • /
    • 2024
  • Extra-oral imaging techniques such as Panoramic X-rays (PXs) and Cone Beam Computed Tomography (CBCT) are the most preferred imaging modalities in dental clinics owing to its patient convenience during imaging as well as their ability to visualize entire teeth information. PXs are preferred for routine clinical treatments and CBCTs for complex surgeries and implant treatments. However, PXs are limited by the lack of third dimensional spatial information whereas CBCTs inflict high radiation exposure to patient. When a PX is already available, it is beneficial to reconstruct the 3D oral structure from the PX to avoid further expenses and radiation dose. In this paper, we propose 3DentAI - an U-Net based deep learning framework for 3D reconstruction of oral structure from a PX image. Our framework consists of three module - a reconstruction module based on attention U-Net for estimating depth from a PX image, a realignment module for aligning the predicted flattened volume to the shape of jaw using a predefined focal trough and ray data, and lastly a refinement module based on 3D U-Net for interpolating the missing information to obtain a smooth representation of oral cavity. Synthetic PXs obtained from CBCT by ray tracing and rendering were used to train the networks without the need of paired PX and CBCT datasets. Our method, trained and tested on a diverse datasets of 600 patients, achieved superior performance to GAN-based models even with low computational complexity.

Rehabilitation using mandibular implant overdenture with CAD/CAM milled bar: A case report (CAD/CAM 시스템으로 제작한 Milled Bar를 이용한 하악 임플란트 피개의치 수복증례)

  • Ban, Min-Hee;Yang, Hongso;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Shin, Jin-Ho;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.292-299
    • /
    • 2017
  • Long-term alveolar bone resorption in edentulous patient causes difficulty in denture use. Applying an implant overdenture with 2 to 4 implants to edentulous patient is easily approachable. Moreover, it improves denture stability, support, and retention. Milled bar, the attachment used in implant overdenture, can be used to induce better stability and retention to the supporting structure than conventional bar. It has become convenient to use due to the development of CAD/CAM system which had allowed the simplification of dental techniques. In this case, application of conventional maxillary full denture and mandibular overdenture made of CAD/CAM milled bar with 4 implants showed satisfactory results in the patient who had used upper and lower full dentures for a long time.

Design and Evaluation of Ultrasonic dental scaler produced for Finite Element Analysis (유한요소 해석을 통한 치과용 초음파 Scaler의 설계 및 평가)

  • Kim, Chul-Min;Lee, Young-Jin;Jeong, Young-Hun;Paik, Jong-Hoo;Kang, Kook-Jin;Lee, Jeong-Bae;Lee, Seung-Dae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.20-20
    • /
    • 2009
  • 치아의 치석제거 및 치골절삭에 사용되는 초음파 스케일러는 일반적으로 마그넷형과 압전형으로 구분할 수 있으며, 최근에 들어 소형화, 저전력, 정밀성, 저비용 등의 장점으로 인해 압전형이 주로 사용되고 있다. 국내의 대부분의 치과에서 한 대 이상 운용되는 초음파 스케일러는 대부분 유럽 제품으로며, 국내에서는 이를 대체하기 위한 제품이 출시되고 있으나 아직까지 유럽 제품에 비해 출력강도, 정밀도 등에서 성능이 모자란 현실로 시장에서 외면 받고 있다. 본 연구에서는 앞서 언급한 압전 초음파 스케일러에 대한 체계적인 연구를 진행하여 외국에 비해 상대적으로 성능이 떨어지는 초음파 스케일러의 성능을 개선하고자 하였다. 이를 위하여 스케일러의 진동 발생부, 즉 압전 세라믹과 SUS 재질의 head, tail 부로 구성된 진동발생부의 최적구조톨 도출하기 위하여 유한요소 해석을 실시하였으며, 스케일러의 중심주파수 28kHz에서 최대 출력이 발생할 수 있는 구조를 도출하였다. 스케일러의 Head 와 Tail 부문의 두께와 직경, 길이 변화에 따른 중심주파수 및 출력 변위의 경향분석을 실시하였으며, 이상의 결과를 바탕으로 실제 스케일러를 제작하여 시뮬레이션의 유효성을 검증하였다. 이상의 과정으로 거쳐 개발된 압전 초음파 스케일러는 다양한 Tip 종류의 영향을 최소화할 수 있으며, 중심주파수는 28~30kHz 에서 뛰어난 성능을 나타내어 기종 유럽제품의 성능을 앞지르는 특성을 확보할 수 있었다.

  • PDF

Managing Complications Related to Multiple Supernumerary Teeth (다수 과잉치로 인한 합병증 치료의 임상적 고찰)

  • Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.180-186
    • /
    • 2014
  • One or two mesiodens are mostly common to the clinician. However, three mesiodens is rarely found and can cause complications such as orthodontic problems or interruptions of the adjacent teeth with more than 1 or 2 mesiodens. Many factors cause irregularities in the permanent dentition. Mesiodens, especially in the anterior maxilla, can disturb the eruption of adjacent permanent teeth and cause diastemas, ectopic eruptions, root resorption, or the formation of dentigerous cysts. The early diagnosis of mesiodens is important for preventing such complications, and the timing of intervention should be based on their location and number. Periodic checkups and improved diagnostic devices make it easy to find mesiodens and associated complications. In this case, 3 supernumerary teeth in the maxillary anterior region were affecting the eruption of the adjacent permanent incisors. To minimize complications and preserve the deciduous teeth, the three supernumerary teeth were extracted in 2 steps. Since cone-beam computed tomography was not available, a brace wire was used to measure the depth of the mesiodens.

Development of Real-Time Face Region Recognition System for City-Security CCTV (도심방범용 CCTV를 위한 실시간 얼굴 영역 인식 시스템)

  • Kim, Young-Ho;Kim, Jin-Hong
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.4
    • /
    • pp.504-511
    • /
    • 2010
  • In this paper, we propose the face region recognition system for City-Security CCTV(Closed Circuit Television) using hippocampal neural network which is modelling of human brain's hippocampus. This system is composed of feature extraction, learning and recognition part. The feature extraction part is constructed using PCA(Principal Component Analysis) and LDA(Linear Discriminants Analysis). In the learning part, it can label the features of the image-data which are inputted according to the order of hippocampal neuron structure to reaction-pattern according to the adjustment of a good impression in a dentate gyrus and remove the noise through the auto-associative memory in the CA3 region. In the CA1 region receiving the information of the CA3, it can make long-term memory learned by neuron. Experiments confirm the each recognition rate, that are shape change and light change. The experimental results show that we can compare a feature extraction and learning method proposed in this paper of any other methods, and we can confirm that the proposed method is superior to existing methods.

CASE REPORTS : TALON CUSP (증례 보고-Talon Cusp)

  • Min, Yu-Jin;Kim, Jong-Su
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2004
  • Talon cusp is cusp-like structure that develops additionally in crown of anterior tooth. And it is one of dental anomalies. Talon cusp can cause various diagnostic, functional, aesthetic problems depending on the size and configuration of cusp. there is a tendency for caries to occur in the developmental grooves, and advanced attrition, periodontal problems, irritation the tongue and temporomandibular pain, occlusal interference and displacement of affected tooth may result. Therefore, early diagnosis and appropriate treatment of each case is important so that it minimize local problems, such as caries, periodontal diseases, and malocclusion. These cases which are in permanent and primary anterior teeth are about gradual reduction forming reparative dentine and complete reduction of talon cusp and root canal therapy which is an alternative and effective form of treatment when gradual reduction of talon cusp may not be possible.

  • PDF

The effect of varying peripheral bone structure and bone density on the occlusal stress distribution of human premolar regions (사람 소구치부위에서 주위골의 구조 및 밀도변화가 교합력에 의한 치아의 응력분포에 미치는 영향)

  • Suh, Ye-Joon;Shim, June-Sung;Lee, Keun-Woo;Chung, Moon-Kyu;Lee, Ho-Yong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • This study used FEM(Finite Element method) based on micro-CT images to see the effects of occlusal force distribution with varying bone density and structure. the mandibular premolar region from human cadaver, thickness of 10mm was imaged using micro-CT. the cross sectional images were taken every $10{\mu}m$. these were reconstructed and the longitudinal image at the mid point of mesiodistal of the speciman was obtained for the specimen for the FEM. The stress disribution produced by a vertical force at 100N and 100N horizontal were analyzed by MSC Nastran FEM Package. according to the result of this study the occlusal force distribution depends on the structure of cancellus bone and for further information on the occlusal force distribution on the tooth and the surrounding structure requires further studies on cancellus bone structure. CEJ of all model show the highest peak and region whice meet teeth and bone show second high peak. Original model and cortical bone add model show different stress distribution. Stress distribution changed according to bone structures and densities.