Journal of the korean academy of Pediatric Dentistry
/
v.33
no.3
/
pp.469-481
/
2006
Among the etiologic factors of enamel corrosion, daily intake has been considered with a profound interest, especially the intake of acidic drinks. It is thought that the rapid consumption of acidic drinks will not only results in the affection to the teeth but also to the surface of the tooth-colored restorative materials. Therefore, the puopose of this study is to examine the alterations occurred in the surface of the tooth-colored materials according to the exposed time, with 3 most common acidic drinks in contact with daily life. Resin-modified glass-ionomer, polyacid-modified composite resin, composite resin were immersed on 0.9% NaCl, Coke, orange juice, sports beverages as 4 groups in each. The surface hardness and the surface roughness of specimens were measured with following methods: before immersion, 1 day after immersion, 1-,2-,3-,4- weeks after immersion. Results were as follows. 1. Tooth-colored restorative materials, with the exception of composite resin, showed statistically significant changes in surface hardness and roughness when immersed on acidic drinks(p<0.05). 2. The degree of change in surface hardness and roughness occurred as follows, in order of severity from greatest to least resin-modified glass-ionomer, polyacid-modified composite resin, composite resin 3. Sports beverages resulted in greater alterations to surfaces than Coke and orange juice. 4. In the SEM image of the groups immersed in acidic drinks, resin-modified glass-ionomer and polyacid-modified composite resin showed loss of filer. Severe cracks were observed, especially on the resin-modified glass-ionomer.
Journal of the korean academy of Pediatric Dentistry
/
v.36
no.4
/
pp.654-666
/
2009
우식활성이 높은 어린이와 청소년 전체를 수용할 수 있는 치면열구전색(치아홈메우기) 사업의 확대 재생산을 위한 방안으로 건강보험 급여에 포함하는 정책이 2009년 12월부터 실시됨에 따라 본 연구는 급여화 기준 설정, 상대가치지수 개발 및 수가산정, 소요 재정추계 등, 급여화 운용을 위한 제반사항을 연구, 개발하는데 그 목적이 있다. 본 연구에서는 치면열구전색술의 적응증, 실시연령, 대상치아등에 대해 문헌고찰과 함께 상기 항목에 대한 정책적인 면에서의 검토를 시행하였으며, 치과의사를 대상으로 전국규모의 설문조사를 실시하여 치면열구전색술의 상대가치지수(RBRVS)와 연계한 의사업무량을 산출하고, 행위 기술서를 작성하였으며, 직접 및 간접비용의 세부내역 산출하였다. 도출된 상대가치지수를 바탕으로 예상수가를 산정하였으며 이를 근거로 대상 연령 및 대상치아, 의료 이용율 대비 재정추계 시행하였다. 이와함께 치면열구전색술의 급여화 순조로운 정착을 위한 외국사례 연구, 보험적용추진을 위해 치면열구전색의 유지율 및 비용효과, 예방적 레진수복과의 차등화문제, 재료적 고찰, 대국민 및 시술기관 대상 홍보 사항 등 급여화에 관련된 제반 사항을 검토, 제안하였다.
Journal of the korean academy of Pediatric Dentistry
/
v.48
no.3
/
pp.280-290
/
2021
Color stability of pulp-capping material is considered vital to the final aesthetic result since the material is placed in the coronal area. The purpose of this study was to compare the color stability of various pulp-capping materials by analyzing color change of tooth over time. A cavity was formed in the crown of the extracted premolar, and 4 types of pulp-capping materials were filled. Color assessment was performed with a spectrophotometer at different intervals: before placement; immediately after material placement; 1 day, 1 week, 2 weeks, 4 weeks, 8 weeks, 12 weeks, and 16 weeks after placement. Proroot white MTA® and TheraCal LC® showed a significant decrease in the L* value and an increase in the ∆E* value over time. In contrast, Biodentine® and Well-RootTM PT showed no significant change in the L* value and maintained a steady ∆E* value. The application of pulp-capping materials containing bismuth oxide as a radiopacifier may result in a color change of teeth. Long-term color stability of pulp-capping materials should be considered when treating teeth with thin enamel thickness or in aesthetically important area.
Kim, Soo-Hwa;Choi, Hye-Sook;Roh, Jj-Yeon;Kim, Kwang-Mahn
Journal of dental hygiene science
/
v.13
no.2
/
pp.165-173
/
2013
The purpose of this study was to evaluate the surface change after 15% carbamide peroxide home bleaching to various restorative materials (composite resin [CR], resin modified glass ionomer [RMGI] and glass ionomer [GI]) and to observe the effect of surface condition of the materials on re-staining. Three esthetic restorative materials (Filtek Z250, 3M, USA; Fuji II LC, GC, Japan; Fuji II, GC, Japan) were used in this study. Twenty specimens per material group were made and divided into two groups (bleached and control). The specimens were immersed in coffee after applying bleaching agent. The color change and surface roughness were measured before and after bleaching and after immersion in coffee. The data were analyzed with SPSS 18.0. The results were as follows: 1. The color of all experiment groups was significantly changed after bleaching (p<0.05). RMGI was the greatest value of ${\Delta}E^*$ and ${\Delta}L^*$. GI and CR groups were in ordering (p<0.05). The ${\Delta}a^*$ value was decreased GI, RMGI and CR. RMGI was only significantly decreased in ${\Delta}b^*$ value (p<0.05). 2. The surface roughness before and after bleaching was significantly different on CR, RMGI and GI (p<0.05). 3. After staining with coffee, the value of ${\Delta}E^*$ was increased in GI, RMGI and CR, furthermore GI and RMGI showed significant difference in the bleaching groups (p<0.05). The ${\Delta}L^*$ value of GI and RMGI was significantly decreased. 4. The change of surface roughness after staining was not significantly different in all groups (p>0.05). The maintenance of color stability in esthetic restorations is one of the most important properties. Tooth whitening is for the aesthetic. Therefore, dental professionals should notice to patients about re-staining after tooth whitening. They should give an instruction that how to prevent and which kinds of agents could be stained.
Statement of problem: At present, as the esthetic demands are on the increase, there are many ongoing studies for tooth-colored post and cores. Most of them are about fiber post and prefabricated zirconia post, but few about one-piece milled zirconia post and core using CAD/CAM (computer-aided design/computer-aided manufacturing) technique. Purpose: The objective of this study was to compare microleakage of endodontically treated teeth restored with three different tooth-colored post and cores. Material and methods: Extracted 27 human maxillary incisors were cut at the cementoenamel junction, and the teeth were endodontically treated. Teeth were divided into 3 groups (n=9); restored with fiber post and resin core, prefabricated zirconia post and heat-pressed ceramic core, and CAD/CAM milled zirconia post and core. After the preparation of post space, each post was cemented with dual-polymerized resin cement (Variolink II). Teeth were thermocycled for 1000 cycles between $5-55^{\circ}C$ and dyed in 2% methylene blue at $37^{\circ}C$ for 24 hours. Teeth were sectioned (bucco-lingual), kept the record of microleakage and then image-analyzed using a microscope and computer program. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: All groups showed microleakage and there were no significant differences among the groups (P>.05). Prefabricated zirconia post and heat-pressed ceramic core showed more leakage in dye penetration at the post-tooth margin, but there was little microleakage at the end of the post. Fiber post and resin core group and CAD/CAM milled zirconia post and core group indicated similar microleakage score in each stage. Conclusion: Prefabricated zirconia post and heat-pressed ceramic core group demonstrated better resistance to leakage, and fiber post and resin core group and CAD/CAM milled zirconia post and core group showed the similar patterns. The ANOVA test didn't indicate significant differences in microleakage among test groups. (P>.05)
Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.
Journal of Dental Rehabilitation and Applied Science
/
v.25
no.4
/
pp.349-360
/
2009
Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.
The purpose of this study is to develope new dental color-space system. Twelve kinds of dental composites and one kind of dental porcelain were used in this study. Disk samples (15 mm in diameter, 4 mm in thickness) of used materials were made and sample's CIE $L^*a^*b^*$ value was measured by Spectrocolorimeter (MiniScan XE plus, Model 4000S, diffuse/$8^{\circ}$ viewing mode, 14.3 mm Port diameters, Hunter Lab USA) The range of measured color distribution was analyzed. All the data were applied in the form of T### which is expression unit in CNU Cons Dental Color Chart. The value of $L^*$ lies between 80.40 and 52.70. The value of $a^*$ are between 10.60 and 3.60 and $b^*$ are between 28.40 and 2.21. The average value of $L^*$ is 67.40, and median value is 67.30. The value of $a^*$ are 2.89 and 2.91 respectively. And for the $b^*$, 14.30 and 13.90 were obtained. The data were converted to T### that is the unit count system in CNU-Cons Dental Color Chart. The value of $L^*$ is converted in the first digit of the numbering system. Each unit is 2.0 measured values. The second digit is the value of $a^*$ and is converted new number by 1.0 measured value. For the third digit $b^*$ is replaced and it is 2.0 measured unit apart. T555 was set to the value of $L^*$ ranging from 66.0 to 68.0, value of $a^*$ ranging from 3 to 4 and $b^*$ value ranging from 14 to 16.
Statement of problem: Recently, as patients' expectation and interest for esthetics are increasing, concerns of esthetic restoration for removable dentures as well as fixed prosthodontics are also increasing. And the color stability of artificial teeth will affect a long term success rate of the denture. But the stain or discoloration of these artificial teeth as well as denture resin has caused esthetic problem. Purpose: This study was designed to evaluate the influence on color stability of artificial teeth when soy sauce, red pepper paste and coffee which many Koreans have eaten were applied. Material and methods: For artificial teeth type(Endura $Anterio^{(R)}$, Physio $Duracross^{(R)}$, Trubyte $Biotone^{(R)}$) selected for the study, 10 specimens each were soaked into individual beakers of soy sauce, red pepper paste, coffee and distilled water. And $L^*$, $a^*$, $b^*$ value were measured for evaluation of the color difference (${\Delta}E^*$) with spectrophotometer on the 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after immersion. Results: 1. ${\Delta}E^*$ value of artificial teeth which were soaked in soy sauce and coffee was various according to soaking periods. However there was significant difference between Trubyte $Biotone^{(R)}$ and Physio $Duracross^{(R)}$ in red pepper paste regardless of soaking period(P<.05). 2. Except for 8 weeks of Endura $Anterio^{(R)}$, 4 weeks and 8 weeks of Physio $Duracross^{(R)}$, artificial teeth soaked in red pepper paste regardless of the type had significant difference of ${\Delta}E^*$ value compared with other groups (P<.05). 3. $a^*$, $b^*$ value of Endura $Anterio^{(R)}$ and Trubyte $Biotone^{(R)}$ which were soaked in red pepper paste had significant difference compared with the value of other group(P<.05). Conclusion: Red pepper paste had the greatest effect on color difference of artificial tooth. Physio $Duracross^{(R)}$ showed relatively less color difference than Trubyte $Biotone^{(R)}$ and Endura $Anterio^{(R)}$. But as ${\Delta}E^*$ difference were all less than 3.3, these artificial resin teeth seemed appropriate for clinical use.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.