A Case of Tracheal Papillomas Treated With Bronchofibroscopic Nd-YAG Laser Therapy (기관지 내시경하 Nd-YAG Laser소각으로 치료 성공한 기관내 유두종)

  • Yoo, Jeong-Soo;Yoon, Soo-Mi;Kim, Mi-Oak;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Jung, Won-Sang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.857-862
    • /
    • 1999
  • In contrast to juvenile laryngeal papillomatosis, which occurs most often in children and teenagers and is usually self limited, soliatry papillomas in adults are one of uncommon tumors of airway, and have a higher incidence of cancer. They are caused by the respiratory infection of human papilloma virus(HPV). They could spread to more distal airways and have a tendency of recurrence after limited surgical excision. Recently endoscopic therapies such as Nd-YAG laser, electrocautery, and cryotherapy provide extremely effective treatment modalities. We report a case of solitary tracheal papillomas in a 48 year-old man who presented with cough, scanty hemoptysis, and functional evidence of central airway obstruction. He was successfully treated by a Nd-YAG laser therapy via fiberoptic bronchoscopy under the local anesthesia.

  • PDF

전신 정위 프레임을 이용한 환자의 움직임 및 외부자세 setup 오차 분석

  • 정진범;정원균;서태석;최경식;지영훈;이형구;최보영
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.59-59
    • /
    • 2003
  • 목적 : 환자의 호흡에 의한 움직임 및 부정확한 환자 자세 setup 때문에 3 차원 전신 정위 방사선치료,3 차원 입체조형 방사선치료 IMRT와 같은 방사선 치료기술에서 병소에 대한 정확한 표적 위치측정은 매우 어려운 실정이다. 그러므로 본 연구는 방사선 치료시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 setup 오차를 감소시키고 환자 전신에 산재한 병소의 위치를 좌표화할 수 있는 전신 정위 프레임 제작과 제작한 프레임에 대한 고정효과 및 재현성을 나타내는 환자 자세의 setup 오차를 평가하는데 있다. 재료 및 방법 : 자체 제작한 전신 정위 프레임 구조는 CT 영상 촬영 가능성에 중점을 두고 병소 표적의 좌표실현 및 환자체형에 따른 다양성 그리고 프레임에 대한 견고성 및 안정성 확인에 초점화하여 제작하였다. 이렇게 제작된 전신 정위 프레임에 대한 방사선 투과율 측정 실험과 CCTV 카메라와 DVR(Digital Video Recorder)를 이용해 환자 자세 변화에 대한 영상을 획득하여 matlab으로 구현한 오차분석용 프로그램으로 환자 외부자세에 대한 오차 비교 평가하고 CT 촬영에 의한 가상표적 위치측정 실험을 수행하였다. 또 한 고정벨트 추가 사용으로 인한 환자의 고정효과 정도를 살펴보았다. 결과 : 제작된 전신 정위 프레임에 대한 방사선 투과율은 마그네트론 10, 21 MeV의 에너지에서 95, 96% 의 투과율이 측정되었고 30 $^{\circ}$. 60 。각도의 경사로 빔이 전달될 때는 90.3, 94.4% 가 측정되었다. CCTV 카메라를 이용하여 흉부 및 복부의 움직임을 촬영한 영상을 Matlab프로그램으로 구현한 오차분석 프로그램을 적용한 결과, 환자 자세에 대한 오차의 평균값은 흉부의 lateral 방향에서는 3.63$\pm$1.4 mm, AP 방향에서는 2.1$\pm$0.82 mm이었다. 그리고 복부의 later의 방향에서는 7.0$\pm$2.1 mm, AP 방향에서는 6.5$\pm$2.2 mm 이었다. 또한 표적 위치측정을 위해서 환자의 피부에 임의의 가상표적을 부착하고 CT 촬영한 영상결과, 프레임으로 가상표 적에 대한 위치를 정확히 파악할 수 있었다. 결론 : 제작된 프레임을 적용하여 방사선투과율 측정실험, 환자 외부자세에 대한 오차 측정실험, 가상표적 위치측정 실험 등을 수행하였다. 환자 외부자세에 대한 오차 측정실험 경우, 더 많은 Volunteer를 적용하여 보다 정확한 오차 측정실험이 수행되어야 할 것이며 정확한 표적 위치 측정실험을 위해서 내부 마커를 삽입한 환자를 적용한 임상실험이 수행되어야 할 것이다. 또한 위치결정에서 획득한 좌표값의 정확성을 알아보기 위해서 팬톰을 이용한 방사선조사 실험이 추후에 실행되어져야 할 것이다. 그리고 제작된 프레임에 Rotating X선 시스템과 내부 장기의 움직임을 계량화하고 PTV에서의 최적 여유폭을 설정함으로써 정위 방사선수술 및 3 차원 업체 방사선치료에 대한 병소 위치측정과 환자의 자세에 대한 setup 오차측정 결정에 도움이 될 수 있을 것이라고 사료된다.

  • PDF

A preliminary study on the Effectiveness of Group Occupational therapy program for Dementia Patient in Day-care center (주간보호시설 치매환자의 집단작업치료프로그램 효과-예비연구)

  • Lee, Seong-A;Jeong, Won-Mee;Hwang, Yun-Jung;Park, Chung-A
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2055-2063
    • /
    • 2015
  • The purpose of this study is to have a preliminary study in order to identify changes in occupational performance skills and visual perception of patients with mild dementia, who have been provided with a group occupational therapy program, within community day-care center. The subjects of this study were 9 people with mild dementia living in a community. The period of administration was for 60 minutes per session three times a week during four weeks. We assessed their visual perception function(MVPT) and occupational performance(AMPS). One group pre-post test design was implemented as an experimental study to compare the results between before and after applying the group occupational therapy program within sensory, physical, creative activity. While a statistically significant difference between before and after the program of motor skills(occupational performance skill) is not shown, the visual perception function and occupational performance of patients with mild dementia improved significantly after receiving occupational therapy program(p<0.01, p<0.05). Therefore, it is possible to conclude that the group occupational therapy program is helpful to manage the occupational performance skills and visual perception of patients with mild dementia in community day-care center.

Clinical Results after Arthroscopic Treatment in Acute Pyogenic Arthritis of the Knee (급성 화농성 슬관절염에서 관절경적 치료 후 결과)

  • Lee, Jung-Hwan;Yoon, Kyoung-Ho;Bae, Dae-Kyung;Kim, Jeong-Weon;Park, Soo-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.53-57
    • /
    • 2008
  • Purpose: We analyzed the clinical results after arthroscopic treatment in acute pyogenic arthritis of the knee. Materials and Methods: From July 2000 to January 2005, we reviewed 16 cases(15 patients) of acute pyogenic arthritis of the knee on which arthroscopic treatment was done. The mean age was 61.9 years and the mean follow-up period was 30.5 months. There were 8 cases with diabetes or degenerative osteoarthritis and 14 cases with acupuncture or intraarticular injection history. Results: Causative organisms were identified in 7 cases. The average postoperative antibiotics were used intravenously for 25.5 days and per orally for 22.5 days. There were 11 complications; 5 cases of partial ankylosis, 2 cases of secondary arthritis, 1 case of chronic osteomyelitis and 3 cases of death. Patients with over 3 week immobilization had higher rate of stiffness of knee joint(p=0.032) but there was no significant difference between the symptom to treatment duration and the incidence rate of complications(p=0.293). The cases of which the causative organism was detected had higher incidences of complications(p=0.034). Conclusion: The incidence of joint stiffness was higher in the patients of longer immobilization. More complications were detected in the cases of which the causative organism is detected.

  • PDF

Implantation Metastasis of Lung Cancer to Chest Wall after Percutaneous Fine-Needle Aspiration Biopsy (흉부 세침 흡인 생검 후 발생한 폐암의 이식성 체벽 전이 2례)

  • Jung, Seung-Mook;Won, Tae-Kyung;Kim, Tae-Hyung;Hwang, Hweung-Kon;Kim, Mi-Young;Jeong, Won-Jae;Lim, Byung-Sung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.6
    • /
    • pp.718-725
    • /
    • 2001
  • The implantation of malignant cells along the needle tract is an extremely rare complication after a percutaneous fine-needle aspiration biopsy(FNAB). However, it is very serious and may result in a change in the prognosis of lung cancer, especially in the curable early stage(T1-2,N0,M0). Recently, we experienced two cases of such complications. A 43 years old female underwent a fine needle aspiration biopsy and a right middle lobectomy with adjuvant chemotherapy due to an adenocarcinoma(T2N0M0). Two years later, a new tumor developed at the site of the needle aspiraton biopsy. It had the same pathological findings as the previous lung cancer. Therefore, it was concluded to be an implantation metastasis, and she was treated successfully by a right pneumonectomy and a resection of the chest wall mass with adjuvant radiotherapy. In another case, a 62 years old man was diagnosed with squamous cell lung cancer by a fine needle aspiration biopsy and underwent a right upper lobectomy(T2N0M0) with adjuvant chemotherapy. eight months later, a protruding chest wall mass developed at the aspiration site. It showed the same pathological findings as the previous lung cancer. Consequently, a total excision of the mass with adjuvant radiotherapy was done. Two years after the second operation, although the right lung was intact, a metachronous squamous cell lung cancer was found at the left lower lobe. The two patients were still alive 15 and 37months after thenresection of the chest wall mass, respectively.

  • PDF

Impact of Respiratory Motion on Breast Cancer Intensity-modulated Radiation Therapy (유방암 세기조절방사선치료에서의 호흡운동 영향)

  • Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.93-97
    • /
    • 2016
  • In this study, we evaluate the effect of respiration on the dose distribution in patient target volume (PTV) during intensity-modulated radiation therapy (IMRT) and research methods to reduce this impact. The dose distributions, homogeneity index (HI), coverage index (CVI), and conformity index of the PTV, which is calculated from the dose-volume histogram (DVH), are compared between the maximum intensity projection (MIP) image-based plan and other images at respiration phases of 30%, 60% and 90%. In addition, the reducing effect of complication caused by patient respiration is estimated in the case of a bolus and the expended PTV on the skin. The HI is increased by approximately twice, and the CVI is relatively decreased without the bolus at other respiration phases. With the bolus and expended PTV, the change in the dose distribution of the PTV is relatively small with patient respiration. Therefore, the usage of the bolus and expended PTV can be considered as one of the methods to improve the accuracy of IMRT in the treatment of breast cancer patients with respiratory motion.

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Self-Expandable metallic Stent in Benign Tracheobronchial Stenosis (양성기관지 협착증 환자에서 팽창성 금속성 스텐트의 사용경험)

  • Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Jeon, Seok-Chol;Chung, Won-Sang;Kim, Kung-Hun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.4
    • /
    • pp.318-324
    • /
    • 1992
  • Acquired tracheobronchial stenosis has resulted from vehicular accidents, prolonged tracheal intubation, sleeve resection, tuberculosis and sarcodosis. Various modalities of therapy for the relief of such stenosis included surgery, cryotherapy, laser photoresection, and sometimes balloon dilatation. Several recent reports have described the use of self-expandable metal stents for the dilatation of stenotic areas in the tracheobronchial tree. Three patients of benign acquired tracheobronchial stenosis were treated with self-expandable metal stents, who had shown little response to several times of balloon dilatations; One patient had a tracheal stenosis caused by intubation, one a right main bronchial stenosis developed after reconstructive surgery of traumatic bronchial rupture, and the other a left main bronchial stenosis caused by longstanding endobronchial tuberculosis. We found that the using stent in benign acquired tracheobronchial stenosis can be effectively performed with alleviation of clinical symptoms and lung function. And even in longstanding localized stenosis of main bronchus without distal bronchial destruction, lung perfusion also improved.

  • PDF

The effect of patient position on dose in radiation therapy of liver cancer (환자 자세가 간의 방사선 치료 시 선량에 미치는 영향)

  • Jung, Won Seok;Kim, Ju Ho;Kim, Young Jae;Shin, Ryung Mi;Oh, Jeong Hun;Jeong, Geon A;Jo, Jun Young;Kim, Gi Chul;Choi, Tae Kyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Purpose : To analyze tumor's movement and volume change from changing position in order to minimize movement caused by breathing. Materials and Methods : We conducted survey of 14 patients with HCC(Hepatocellular carcinoma). Patient immobilization device was made in two ways(Supine position, prone position) and from image acquisition, tumor's movement, volume and dose are analyzed. Results : The mean movement of target(LR, Left-right) in supine position and prone position was $2.76{\pm}1.25mm$, $2.21{\pm}0.93mm$. AP(Anterior-posterior) and SI(Superior-inferior) was $4.02{\pm}1.63mm$, $11.56{\pm}3.08mm$, $3.36{\pm}1.17mm$, $7.45{\pm}1.96mm$. Treatment volume was decreased and normal liver volume was increased in prone position. Conclusion : We could reduce the margin of the treatment volume by minimizing the movement of liver caused by breathing. Especially in prone position, it is considered to be able to decrease the movement of the liver and increase normal liver volume.

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.