• Title/Summary/Keyword: 치료보조기구

Search Result 37, Processing Time 0.023 seconds

A Report of the Assistive Technology Service Operating System for the Disabled in Sweden (스웨덴 장애인 보조기구 제공 시스템에 대한 소고)

  • Choi, Young Soon
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.25-45
    • /
    • 2014
  • The present report aims to examine the assistive technology(AT) service operating system for the Disabled in Sweden, and will give it to NHIS(National Health Insurance Service) to manage of policy for AT service operating system. The user of AT is around 10% of the Disabled in Sweden which is introduced the AT service system to support the independence for the Disabled. To provide AT service, the role of the Ministry of Health(planning and regulation, controling Handisam and Hi as a subsidiary), County councils(providing and follow up medical AT service, operating AT service center) and Municipalities(providing general AT service) in Sweden is decentralized strictly. Specially, all the AT device is lent freely and recycled suitably for persons with Disabilities, moreover nurses, physical therapist and occupational therapist has a qualification for prescription of AT device . This finding will be the basis to improve Assistive Technology Operating System in Korea.

Arm-up holder의 보조기구 제작에 따른 유용성 평가

  • 이현직;최병기;심재구;김종식;오동균;박영환
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.85-88
    • /
    • 2002
  • I. 목적 : arm-up holder는 흉부 및 복부 질환 치료의 환자고정에 유용하게 사용하고 있으나 손잡이 부분과 어깨가 닿는 부분까지 거리 때문에 동일한 자세를 유지하는데 불편함이 있다. 특히 긴장을 많이 하거나 기력이 없는 환자는 방사선 치료 시 자세의 불안정으로 인하여 치료의 정확성이 떨어질 수 있다. 이에 본원에서는 현재 사용하고 있는 arm-up holder에 팔의 지지를 위한 보조기구를 제작하여 유용성을 평가하였다. II. 대상 및 방법 : 기존의 arm-up holder에 어깨받침대를 부착하여 개선된 arm-up holder를 제작하였다. 실험을 위하여 기존의 arm-up holder를 사용하는 환자그룹과 개선된 arm-up holder를 사용하는 그룹으로 구분하여 자세 변화를 평가하였다. 두 그룹의 환자를 대상으로 모의 치료를 실시한 후 치료실에서 L-gram 을 2회 씩 촬영하여 치료하고자 하는 portal film과 isocenter의 변화를 측정했다. 각 그룹 당 10명씩의 환자를 선정하여 반복 조사하였다. III. 결과 : 개선된 arm-up holder를 사용한 그룹의 isocenter 의 변화는 최대 2mm, 최소 0.5mm 평균 1.2mm 이다. 기존의 arm-up folder를 사용한 그룹과 비교하여 평균변화는 약 2배로 나라났고, 최대 변화는 2.5배의 오차범위가 측정되었다. IV. 결론 : 현재 사용하고 있는 arm-up holder는 흉부 및 복부의 사방향 방사선 치료 시 팔에 의한 방사선 감약을 예방할 수 있는 유용한 고정용구이다. 하지만 팔을 올리고 있는 자세는 환자에게 불편함을 야기 시키며 이로 인한 치료의 정확성을 감소시킬 수 있다. 따라서, 기존의 arm-up holder에 보조기구를 제작하여 사용함으로써 환자의 불편함을 개선하고, set-up 의 안정성과 재현성을 향상시킬 수 있었다.

  • PDF

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF

Clinical Outcomes of Associated with Adaptive Seating Device Using FIATS-AS (FIATS-AS를 활용한 자세보조기구의 기능적 효과평가)

  • Kwon, Hyuk Cheol;Kong, Jin Yong
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.207-220
    • /
    • 2014
  • The purpose of this study is to determine the parent-perceived effect of adaptive seating devices on the lives of infant or young children with physical and brain lesion disabilities(age 1-13y) and their families. Using the seating device for disabled parents of 42 people with disabilities who use FIATS-AS to investigate functional outcomes. All parents completed the FIATS-AS 4 times-2 times before and 2 times after their child received a new adaptive seating system. Repeated-measures analysis of variance detected significant mean differences among the FIATS-AS scores. Also to estimating the impact of the new seating intervention for the 3 age cohorts using the FIATS-AS scores. The FIATS-AS detected a significant interaction between age cohort and interview time. Providing adaptive seating devices has been found that the positive effects on guardians. The change was significant in 1~7 years of age. Environmental modification, such as seating and other assistive technology devices, may have an important role to play in the lives of young children with disabilities and their families.

Evaluating Surface dose of Treatment Immobilization Devices according to their Electron Energy (전자선에너지에 따른 치료보조기구의 표면선량 평가)

  • Park, Chul-Woo;Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.360-363
    • /
    • 2010
  • This study evaluated surface dose of treatment immobilization devices such as Themo-plastic, Vac-lock, Cotton and Plaster according to their electron energy. Using a linear accelerater, a plane parallel chamber was set up on 6Mev, 9Mev, 12Mev and 15Mev. A distance between a source and a surface was 100cm and a field size was 10cm*10cm. An incident angle was 0 degree and a radiation dose was 100MU. To decrease an error, the measurement repeated 3 times. The analysis reveals that the surface dose of Vac-lock was the highest and Themo-plastic, Plaster and Cotton were high in order.

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Design of Finger rehabilitation device using Digital Servo-Motor (디지털 서보모터를 이용한 손가락 재활기구의 설계)

  • Choi, Duk-Kyu;Mun, Min-Gi;Seo, Ji-Hun;Mun, In-Ju
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.01a
    • /
    • pp.185-186
    • /
    • 2018
  • 기존의 재활치료기구는 부피가 크고 고비용으로 재활치료센터 운영시간에 맞춰 통원하며 이용해야 하는 불편함이 있었다. 이러한 불편함을 해소하기 위해 제안하는 디지털 서보모터 재활 보조기구는 사용자의 상태에 맞게 전문가와 상의하여 구동수치와 손 안쪽의 와이어의 길이를 수정 한 후 사용하는 것을 원칙으로 사용자가 손가락 끝(지문)에 부착된 감압센서를 누르는 강도와 힘의 유지 유무에 따라 손가락을 굽히거나 펴는 행위를 훈련 할 수 있도록 한 재활치료기구이다. 본 논문의 구현결과는 향후 프로토타입을 보완하여 출력과 운용 방법을 기존과 달리 한다면 다양한 재활기구에 응용될 수 있을 것으로 사료된다.

  • PDF

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

치태관리

  • Kim, Byeong-Ok
    • The Journal of the Korean dental association
    • /
    • v.36 no.3 s.346
    • /
    • pp.199-202
    • /
    • 1998
  • 1940년대부터 1970년대까지 치주치료의 목적은 복잡핞 치주외과적 수술을 통하여 치주낭을 제거 또는 감소시키는 것이었다. 그러나 1960년대와 1970년대에 이루어진 연구 결과를 보면 치주질환의 병인발생에 있어서 치태의 역할과 적절한 구강위생의 중요성이 강조되었다. 즉 치태를 제거하기 위해서 치솔과 치약, 그리고 보조기구를 이용한 구강위생방법(기계적인 처치)과 전신적 및 국소적 항생제투여, 그리고 양치용액의 사용(화학적인 처치)과 같은 비외과적 처치방법이 관심의 대상이 되었다. 여기에서는 치태를 효과적으로 관리하기 위한 기계적인 치료방법과 화학적인 치료방법에 대해 살펴보고자 한다.

  • PDF