Oral rehabilitation with magnetic overdentures for an old patient with complex systemic diseases (복합적인 전신질환이 있는 안면마비 환자의 양악 자성 피개의치 수복 증례)

  • Ko, Eunjin;Ahn, Sujin;Lee, Sukwon;Park, Sujung;Lee, Richard Sungbok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • As dental implant treatment becomes popular for both partial and complete edentulous patients, old people with complex systemic diseases also tend to prefer implant-assisted-overdenture or implant-supported-fixed prostheses to conventional complete denture. In this case, 77-year-old female who was on medication for hypertension and osteoporosis and paralyzed on right side due to stroke visited for implant-assisted-overdenture on lower jaw. After oral and radiographic examination, root-assisted magnet overdenture on upper jaw and implant-assisted magnet overdenture on lower jaw are planned. Consequently, overdentures using self-adjusting magnetic attachment(SA) system on both jaws resulted in recovering satisfying function and retention, which is enable to insert and remove with only one hand.

Quantitative analysis of mutans streptococci adhesion to various orthodontic bracket materials in vivo (다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석)

  • Yu, Jin-Kyoung;Ahn, Sug-Joon;Lee, Shin-Jae;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.105-111
    • /
    • 2009
  • Objective: To estimate the effects of bracket material type on enamel decalcification during orthodontic treatment, this study analyzed the adhesion level of mutans streptococci (MS) to orthodontic bracket materials in vivo. Methods: Three different types of orthodontic bracket materials were used: stainless steel, monocrystalline sapphire, and polycrystalline alumina. A balanced complete block design was used to exclude the effect of positional variation of bracket materials in the oral cavity. Three types of plastic individual trays were made and one subject placed the tray in the mouth for 12 hours. Then, the attached bacteria were isolated and incubated on a mitis salivarius media containing bacitracin for 48 hours. Finally, the number of colony forming units of MS was counted. The experiments were independently performed 5 times with each of the 3 trays, resulting in a total of 15 times. Mixed model ANOVA was used to compare the adhesion amount of MS. Results: There was no difference in colony forming units among the bracket materials irrespective of jaw and tooth position. Conclusions: This study suggested that the result of quantitative analysis of MS adhesion to various orthodontic bracket materials in vivo may differ from that of the condition in vitro.

Current Status of Imaging Physics & Instrumentation In Nuclear Medicine (핵의학 영상 물리 및 기기의 최신 동향)

  • Kim, Hee-Joung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.83-87
    • /
    • 2008
  • Diagnostic and functional imaging device have been developed independently. The recognition that combining of these two devices can provide better diagnostic outcomes by fusing anatomical and functional images. The representative examples of combining devices would be PET/CT and SPECT/CT. Development and their applications of animal imaging and instrumentation have been very active, as new drug development with advanced imaging device has been increased. The development of advanced imaging device resulted in researching and developing for detector technology and imaging systems. It also contributed to develop a new software, reconstruction algorithm, correction methods for physical factors, image quantitation, computer simulation, kinetic modeling, dosimetry, and correction for motion artifacts. Recently, development of MRI and PET by combining them together was reported. True integration of MRI and PET has been making the progress and their results were reported. The recent status of imaging and instrumentation in nuclear medicine is reported in this paper.

Clinical crown angulation and inclination of normal occlusion in a large Korean sample (정상교합자의 치관경사도에 관한 연구)

  • Lee, Shin-Jae;Ahn, Sug-Joon;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.331-340
    • /
    • 2005
  • Angulation and inclination of clinical crown is important for diagnosing, treatment planning and developing convenient orthodontic attachments. The aim of the study was to establish normative data with higher reliability on the angulation and inclination of clinical crown of Koreans with normal occlusion This study employed the dental casts of 307 (male. 187: female. 120) adult normal occlusion samples. The angulation and inclination of clinical crown were measured by set-up model checker In order to ensure reliability, intra- and inter-rater error were evaluated 3 times The resultant data obtained had excellent reliability however when compared with the previous data as well as with gender difference, clinically significant interpretation was impossible because the whithin-dataset normal variation was High which was common pattern of angulation and inclination measuring data of previous research The result of this biometric study seemed 4o suggest more substantive design of the multivariate. high-dimensional interpretation methodology of these normal variation is required if more compatible orthodontic appliance could be developed.

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

Analysis of the Respiratory Motion Effects on Dose Distribution Using TLD Phantom (열형광선량계용 팬톰을 이용한 호흡 움직임에 따른 선량분포의 평가)

  • Hong, Ju-Young;Kim, Yon-Lae;Rah, Jeong-Eun;Chung, Jin-Beom;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.187-191
    • /
    • 2006
  • The purpose of this study was to measure the dose distribution from the moving phantom for the respiratory motion. The phantom for TLD measurement was designed and built for this study based on the multiple plates for placing TLD and film. The TLDs may be inserted at 3 mm intervals in each TLD plate. For the measurements, TLD plate was inserted into the phantom at 1.5 cm ($d_{max}$) depth, and phantom was allowed to move in SI directions in the range of 1 to 2 cm with 0.5 cm interval for 6 MV X-ray beams. Penumbra and FWHM were measured at both moving state and compared stationary. It was found that penumbra increased 0.71 cm at stationary and 2.10 cm at moving state in 2 cm movement, and that FWHM are 7.52 cm for stationary state and 7.02 cm for moving state (2 cm movement). In this study, film was used to compared with TLD results of measurements and simitar results were observed. Therefore, it is expected that TLD moving phantom may be useful for the treatment of tumors that move due to the respiratory motion.

  • PDF

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

Comparison of Intensity Modulated Radiation Therapy Dose Calculations with a PBC and AAA Algorithms in the Lung Cancer (폐암의 세기조절방사선치료에서 PBC 알고리즘과 AAA 알고리즘의 비교연구)

  • Oh, Se-An;Kang, Min-Kyu;Yea, Ji-Woon;Kim, Sung-Hoon;Kim, Ki-Hwan;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.48-53
    • /
    • 2012
  • The pencil beam convolution (PBC) algorithms in radiation treatment planning system have been widely used to calculate the radiation dose. A new photon dose calculation algorithm, referred to as the anisotropic analytical algorithm (AAA), was released for use by the Varian medical system. The aim of this paper was to investigate the difference in dose calculation between the AAA and PBC algorithm using the intensity modulated radiation therapy (IMRT) plan for lung cancer cases that were inhomogeneous in the low density. We quantitatively analyzed the differences in dose using the eclipse planning system (Varian Medical System, Palo Alto, CA) and I'mRT matirxx (IBA, Schwarzenbruck, Germany) equipment to compare the gamma evaluation. 11 patients with lung cancer at various sites were used in this study. We also used the TLD-100 (LiF) to measure the differences in dose between the calculated dose and measured dose in the Alderson Rando phantom. The maximum, mean, minimum dose for the normal tissue did not change significantly. But the volume of the PTV covered by the 95% isodose curve was decreased by 6% in the lung due to the difference in the algorithms. The difference dose between the calculated dose by the PBC algorithms and AAA algorithms and the measured dose with TLD-100 (LiF) in the Alderson Rando phantom was -4.6% and -2.7% respectively. Based on the results of this study, the treatment plan calculated using the AAA algorithms is more accurate in lung sites with a low density when compared to the treatment plan calculated using the PBC algorithms.

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF