• Title/Summary/Keyword: 치관 수복

Search Result 116, Processing Time 0.02 seconds

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.

Influence of Sodium Hypochorite & EDTA on the Microtensile Bond Strength of Ethanol Wet Bonding (Ethanol Wet Bonding에서 NaOCl과 EDTA가 결합강도에 미치는 영향)

  • Kim, Deok-Joong;Song, Yong-Beom;Park, Sang-Hee;Kim, Hyoung-Sun;Lee, Hye-Yoon;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • Sodium hypochlorite and ethylene diamine tetra acetic acid are substances usually used during endodontic treatment. Several studies found that the bonding was negated with certain irrigants and some of the used irrigants have demineralizing and chealating effects, so it was advocated to omit the etching step in etch and rinse adhesive systems. The purpose of this in vitro study was to evaluate the influence of NaOCl & EDTA on the bonding strength of ethanol wet bonding. Thirty human molars were selected and mesiodistally sectioned into halves, thus providing sixty specimens. The specimens were randomly assigned to 4 groups(n=15) according to the irrigant regimen used : (1) irrigated with distilled water for 10min (control); (2) irrigated with 5.25% NaOCl(10min), flushed with 5.25% NaOCl(1min) (3) irrigated with 5.25% NaOCl, flushed with 17% EDTA (4) irrigated with 5.25% NaOCl, flushed with 17% EDTA. Each group was acid-etched with 37% phosphoric acid(except group 4) and had their dentin surfaces dehydrated with ethanol solutions : 50%, 70%, 80%, 95%, 3x100%, 30s for each application. After dehydration, a primer( 50% all bond 3 resin + 50% ethanol) was used, followed by the adhesive(ALL-BOND 3 RESIN) application. Resin composite build-ups were then prepared using an incremental technique. Specimens were sectioned into beams and submitted to a tensile load using a Micro Tensile Tester(Bisco Inc.). The data were statistically analyzed using one-way ANOVA and Tukey HSD at p<0.5 level. There was no significant difference on G1(control) and G2(irrigated with NaOCl only ). (p>0.05). G3(flushed with EDTA) showed significantly high tensile bonding strength compared to the G2 (p<0.05). G4( treated with EDTA but no acid-etching) was significantly lower value than G3. (p<0.05) Although there was no significant difference, 5.25% NaOCl seemed to have an adverse effect on the bonding strength of ethanol wet bonding. The flushing with EDTA after NaOCl irrigation prevents the decrease of bonding strength. The use of 17% EDTA as a final flush can enhance the bonding strength but EDTA flushing can't substitute for a acid-etching.

EFFECT OF ULTRASONIC VIBRATION ON ENAMEL AND DENTIN BOND STRENGTH AND RESIN INFILTRATION IN ALL-IN-ONE ADHESIVE SYSTEMS (All-in-one 접착제에서 초음파진동이 법랑질과 상아질의 결합강도와 레진침투에 미치는 영향)

  • Lee, Bum-Eui;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.66-78
    • /
    • 2004
  • The objective of this study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration in enamel and dentin achieved with those gained using the conventional technique and vibration technique. For enamel specimens, thirty teeth were sectioned mesio-distally. Sectioned two parts were assigned to same adhesive system but different treatment(vibration vs. non-vibration). Each specimen was embedded in 1-inch inner diameter PVC pipe with a acrylic resin. The buccal and lingual surfaces were placed so that the tooth and the embedding medium were at the same level. The samples were subsequently polished silicon carbide abrasive papers. Each adhesive system was applied according to its manufacture's instruction. Vibration groups were additionally vibrated for 15 seconds before curing. For dentin specimen, except removing the coronal part and placing occlusal surface at the mold level, the remaining procedures were same as enamel specimen. Resin composite(Z250. 3M. U.S.A.) was condensed on to the prepared surface in two increments using a mold kit(Ultradent Inc., U.S.A.). Each increments was light cured for 40 seconds. After 24 hours in tap water at room temperature, the specimens were thermocycled for 1000cycles. Shear bond strengths were measured with a universal testing machine(Instron 4465, England). To investigate infiltration patterns of adhesive materials, the surface of specimens was examined with scanning electron microscope. The results were as follows: 1. In enamel the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration group(group 1, 3, 5). The differences were statistically significant except AQ bond group. 2. In dentin, the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration groups(group 1, 3, 5). But the differences were not statistically significant except One-Up Bond F group. 3. The vibration group showed more mineral loss in enamel and longer resin tag and greater number of lateral branches in dentin under SEM examination.

  • PDF

AN INVESTIGATION OF TRAUMATIC DENTAL INJURIES IN CHILDREN (소아의 치아와 지지조직 외상에 관한 분석)

  • Baik, Byeong-Ju;Yang, Yeon-Mi;Yang, Cheol-Hee;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.600-612
    • /
    • 2001
  • The purpose of this study is concerned with an investigation of the actual condition of traumatic injuries of teeth and supporting structures in children to set up possible criteria for prevention and treatment of injured teeth. The materials consisted of the clinical records of 431 traumatically injured teeth of 212 children, accumulated during two years from the first of April in 1998 to the end of March in 2000, supplied from the Dept. of Pediatric Dentistry, Chonbuk National University Hospital. The incidence of injuries in boys was extremely high for permanent teeth, twice as high as in girls. Accidents to primary teeth were most common from 1 to 2 years of age and to permanent teeth were most from 8 to 9 years of age. The most common cause of trauma was a fall for both primary and permanent teeth, followed by collision. The anterior teeth in maxilla was most frequently affected by trauma in both the primary and permanent teeth. The most common type of trauma were loosening for the primary teeth, followed by luxation types which included the intrusion, displacement and extrusion and complete avulsion types. For the permanent teeth, the most common type of trauma were tooth fracture. The most common trauma of soft tissue was laceration of upper lip, lower lip and gingiva of maxilla Concerning treatment at the first visit, primary teeth with only loosening and concussion were not usually treated. Permanent teeth were often treated by crown restorations for crown fractures and by endodontic procedures for pulpal exposure. Though we could elucidate actual condition of traumatic injuries of teeth in children, we should make a follow-up survey to ensure the prognosis of injured teeth and establish the most desirable criteria for traumatized teeth in children.

  • PDF

INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR (설측 복합레진 색상이 치아 순측 색상에 미치는 영향)

  • Mun, Seung-Hui;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.309-323
    • /
    • 2009
  • In this study we evaluated the influence of both the thickness of residual enamel and the color of the composite resins applied to lingual surface on the labial surface color. Background plates were made by randomly (A1, A2, A6D, B1, B2, B3, C1, C2, C6D) selected colors of Filtek Supreme (3M ESPE, St. Paul, U.S.A.) composite resin. Crown portion of 9 maxillary central incisors were cut off and embedded with acrylic resin except labial surface. Samples of average thickness of 2.2 mm were obtained after cutting it in a thickness of 2.5 mm from the labial surface and sandpaper polish. The shade of composite resin background was measured using Spectrophotometer ($Spectrolino^{(R)}$, GretagMacbeth, Regensdorf, Switzerland). And CIE $L^{\ast}a^{\ast}b^{\ast}$value of 2.2 mm thickness tooth samples were measured on the 9 composite resin backgrounds. And then, the cutting side of tooth samples was ground to the extent of 1.9 mm, 1.6 mm, 1.3 mm, 1.0 mm and placed on composite resin backgrounds and measured $L^{\ast}a^{\ast}b^{\ast}$values with the same method. In all samples, $L^{\ast}$value and $b^{\ast}$value seemed to have a tendency of decreasing as thickness of tooth sample becomes thinner regardless of background colors (p < 0.05). But, $a^{\ast}$value didn't show the significant differences depending on the thickness.

Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position (구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구)

  • Soo-Young Hong;Seon-Ki Lee;Jin-Han Lee;Jae-In Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.101-112
    • /
    • 2023
  • Purpose. This retrospective study was to investigate the survival and complication rates of posterior single implant according to the implant diameters, lengths and position. Materials and methods. Patients who had been restored single implant prosthesis in the posterior area by the three prosthodontists in the department of prosthodontics, Daejeon dental hospital of Wonkwang university, in the period from February 2014 to May 2018 were selected for the study. A total of 505 patients with 697 implants were observed. The survival and complications of implants were investigated using electronic medical records and radiographs. Fixture diameters, lengths, position, patient's sex and age were assessed as possible factor affecting the survival and complications of implants. Results. 3-year cumulative survival rates of posterior single implants were 98.5% and 5-year cumulative survival rates were 94.4%. 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm (97.0%) than implants with diameter ≤ 4.0 mm (89.5%), and in females (98.8%) than males (92.4%). There were statistically significant differences (P < .05). The mechanical complication rate was 20.1% and the biological complication rate was 4.7%. Complications occurred in order of abutment screw loosening (7.5%), decementation (6.3%), proximal contact loss (3.7%) and so on. Abutment screw loosening occurred more frequently in the lower molar region (10.5%), in males (9.5%) than females (5.1%), and in patients aged < 65 years (9.4%) than patients aged ≥ 65 years (5.1%). There were statistically significant differences (P < .05). Conclusion. The 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm than implants with diameter ≤ 4.0 mm and in females than males. Abutment screw loosening which was the most commonly occurring complication occurred more frequently in the lower molar region, in males than females, and in patients aged < 65 years than patients aged ≥ 65 years. There were statistically significant differences.