• Title/Summary/Keyword: 치과 X-선 영상

Search Result 26, Processing Time 0.02 seconds

COMPARISON OF FOUR PANORAMIC DENTAL RADIOGRAPHIC SYSTEMS FOR TOOTH ANGULATION MEASUREMENT ACCURACY UNDER DIFFERENT TOLERENCES (치아장축 각도 측정 정확도에 대한 4종 파노라마 방사선 촬영기의 비교)

  • Burson Stacee Dumas;Farman Allan George;Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.317-326
    • /
    • 1994
  • Panoramic radiographs of a dry skull were used to evaluate the accuracy of four panoramic dental X-ray systems in determining tooth angulations in the buccal segments. The four machines evaluated were the Philips Oralix Pan DC, the GE panelipse, the SS White panorex 1, and the SS White Panorex 2. Panoramic radiographs were taken at six different patient positions for each machine to evaluate the effects of patient positioning on determining tooth angulations in the buccal segments. All of the machines studied showed a significant correlation between the mean radiographic estimates and the actual measurements regardless of positioning(p<0.05). With correct placement of the skull, the results were analyzed for an error tolerance of +/-3/sup 0/ between the actual measurements and the radiographic estimates for tooth angulation. The SS White Panorex 1 was accurate 74% of the time, the GE Panelipse was accurate 67% of the time, the Philips Oralix Pan DC and the SS White Panorex 2 were accurate 64% of the time. When an error tolerance of +/-5/sup 0/ was permitted, the accuracy was 89% for the SS White Panorex 1 and the GE Panelipse, 85% for the Philips Oralix Pan DC, and 81% for the SS White Panorex 2.

  • PDF

Age-dependent Difference in the Computed Tomography Numbers of the Normal Parotid Gland of Koreans (나이에 따른 한국인 정상 이하선의 전산화단층촬영값의 차이)

  • Jeong Ho-Gul;Lee Eun-Sook;Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.451-458
    • /
    • 1999
  • Purpose : To determine normal CT number range of parotid gland by analyzing the change by age increase and the difference among individuals and between both sexes in CT number of normal parotid gland. Materials & Methods : 134 subjects who took the CT scan between the period of Jan. 1996 and Dec. 1997 at Yonsei University, Dental Hospital were selected. Criteria for selection were that the patients must be within the normal range clinically and radiologically, and the entire parotid gland on the axial view must be shown. Among the axial views. the one showing the greatest parotid gland size was selected and its CT number was recorded. Also. CT numbers from both masseter muscle were recorded as its control. Results : There was statistically significant correlation between CT number of right and left of parotid glands and masseter muscles. With the increase of age. there is a significant decrease in the CT number of parotid gland(p<0.05). There was no statistically significant difference in CT number between sexes except the 7th decade and beyond age group of parotid gland(p>0.05). Conclusion : As age increases, CT number of parotid gland has a tendency to decrease, and there is no significant difference in the CT numbers between left and right parotid gland. Therefore in the CT scan of patients suspected of having a salivary gland disease of the parotid gland. to consider normal range of the age-dependent CT numbers of parotid gland and compare the CT numbers of the right and left parotid gland might be useful in diagnosing the disease.

  • PDF

AN IMMUNOHISTOCHEMICAL STUDY ON DNA SYNTHESIS OF SALIVARY GLAND TISSUE CEllS AND ENDOTHELIAL CELL AFTER IRRADIATION (방사선조사 후 타액선 세포와 혈관 내피세포의 DNA합성에 관한 면역조직학적 연구)

  • Shin Jong-Sup;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.183-197
    • /
    • 1991
  • After single fraction of 2, 5, 10 Gy irradiation on submandibular gland of 40 male rats, weighing 150gm, respectively, these animal were sacrificed two hours after 0.1㎎/g bromodeoxyuridine (Sigma) peritoneal injection in 1, 3, 7, 15 hours, 1, 3, 7 days after irradiation. And excised submandibular gland were fixed in Carnoy's and Bouin's solution for 2 hours. Paraffin sections were stained with H&E, and PAS for the observation of the change of salivary gland tissue, and with Feulgen for the study of the DNA distribution, and immunohistochemically stained with anti-bromodeoxyuridine (Sanbyo Co.) for detection of DNA synthetic cells in order to study the distribution of DNA synthetic cells of salivary gland tissue and endothelium after irradiation in 5 different sites of 6 slides on X 200 high power field. The results were as followings. 1. In PAS staining 3 days after 5Gy irradiation, decreased mucine secretion of serous cells were found, and 7 days after l0Gy irradiation, decreased mucine secretion of mucous cells were found. 2. In histopathologic features, degeneration of serous cells were found in 3 days after 2 Gy irradiation and there was little change in mucous cells and excretory duct cells. 3. In Feugen staining, 3 days after 2 Gy, 5 Gy irradiation, more high percentage of DNA synthetic cells were found in intercalated duct cells, striated duct cells and excretory duct cells than in BrdU staining. 4. In immunohistochemical features, DNA synethsis of serous cells and granular convoluted tubular cells abruptly decreased in early period after irradiation and showed no recovery in 7 days after irradiation but there was an increase in DNA synthesis of intercalated duct cells, striated duct cells and excretory duct cells, which have less S-phase cells comparatively, in 7 days after 2 Gy, 5 Gy irradiation. 5. In immunohistochemical features, the DNA synthesis of endothelial cells was continuously decreased after irradiation but showed slight increase in 7 days after 2 Gy and S Gy irradiation.

  • PDF

THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST (Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구)

  • Yoo Young Sun;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

OBSERVATION OF CONDYLES BY ROENTGENOGRAPHIC CEPHALOGRAM (두부X-선규격계측사진에 의한 하악두의 관찰)

  • Ahn Hyung Kyu
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.135-140
    • /
    • 1984
  • In spite of many projections of TMJ, there are rarely satisfactory projections of TMJ. The author traced and measured the P-A cephalograms, which number is 70 in each male and female, them finding the following results. 1. The long axis of the condyle is 19.80㎜ on the right, and 19.89㎜ on the left in male, and that of 18.65㎜ on the right and 18.10㎜ on the left in female. 2. The intercondylar distance is 119.02㎜ in male, and 108.20㎜ in female, resulting that the intercondylar distance in male is much longer than that in female. 3. The right and left deviation of the midline passing through the center of the intercondylar distance and prosthion is +0.37㎜ in male, +0.64㎜ in female, and its range is from -4.6 to +5.7㎜ in male, and from -3.2 to +6.1㎜ in female, resulting that prosthion nearly coincides with midline. 4. The angle of the intercondylar distance and the long axis (vertical angle) is +5.48' in male, and +6.02' in female, resulting that there is a little difference between male and female and the angle of the right is greater than that of the left in both male and female. 5. The typology of the condyle in sum of male and female is; Right: A type 55 (39.3%), B type 66 (47.1%), C type, 12 (8.6%), D type, 7 (5.0%), E type, 0 (0%) Left: A type, 60 (42.9%), B type, 58 (41.4%), C type, 14 (10.0%), D type, 8 (5.7%), E type, 0 (0%) 6. The distribution of the typology between the right and the left is; AA 26 (18.6%), AB 50 (35.7%), AC 10 (7.1%), AD 3 (2.1%) BB 26 (18.6%), BC 13 (9.3%), BD 9 (6.4%), CC 0 (0%), CD 3 (2.1%)

  • PDF

Studies on Quantitative Analysis of Salivary Gland using Computed Tomography (전산화단층사진을 이용한 타액선의 정량분석에 관한 연구)

  • Lee Sang-Chul;Lee Sam-Sun;Heo Min-Suk;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.209-221
    • /
    • 1999
  • Purpose: The purpose of this study was to calculate the size and CT number of both normal parotid and submandibular gland. and evaluate their relation to sex, age and obesity using computed tomography. Materials and Methods: The computed tomography was performed parallel to the Frankfurt plane in 46 subjects with healthy salivary gland. The subjects were divided into the three groups (young, middle. old) according to their ages. The size of salivary gland was determined as maximum cross-sectional area and the CT number of salivary gland was determined as the mean CT number of three ROI's. The body mass index was calculated from weight and height. Results: The mean maximum cross-sectional area was 7.79(±1.25)cm² on parotid gland and 4.12(±0.83) cm² on submandibular gland. The mean CT number was -4.43(±23.87) HU on parotid gland and 50.01(±15.63) HU on submandibular gland. There was decreasing pattern of the maximum cross-sectional area of submandibular gland and the CT number of both parotid and submandibular gland according to age(p<0.05). As the body mass index increased. the maximum cross-sectional area of parotid gland increased and CT number of both parotid and submandibular gland decreased(p<0.05). The maximum cross-sectional area of submandibular gland in male was larger than that in female(p<0.05). As the maximum cross-sectional area and CT number of left salivary gland increased. those of right gland increased(p<0.05). Conclusion : Intra-individual differences in salivary gland size and CT number is considered in the age and individual obesity.

  • PDF