• Title/Summary/Keyword: 치과 심미

Search Result 1,136, Processing Time 0.024 seconds

Assessment of antero-posterior skeletal relationships in adult Korean patients in the natural head position and centric relation (자연 두부 위치 및 안정위에서 한국 성인 환자 골격의 전.후 관계 결정)

  • Ahn, Jang-Hoon;Bae, Kwang-Hak;Park, Young-Ju;Hong, Ryoon-Ki;Nam, Joeng-Hun;Kim, Mi-Ja
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.421-431
    • /
    • 2010
  • Objective: This study aimed to verify the intra-individual reproducibility of the natural head position (NHP) in adult Korean patients in the centric relation (CR) position and to prove the inter-individual variability of the Frankfurt horizontal (FH) plane and sella-nasion (SN) line compared to the true horizontal line (THL). In addition, the study aimed to investigate the correlations between linear measurements from A-point and B-point to the nasion true vertical line (NTVL) and angular measurements from A-point and B-point to the SN line. Methods: Two lateral cephalograms were taken of 116 subjects (23 males, 93 females) with CR wax bites in a NHP at a one-week interval. Results: Method errors of three variables and intraclass correlation coefficients of six parameters proved the intra-individual reproducibility of NHP (p < 0.001). The angle of the FH to the THL was not significantly different from $0^{\circ}$ (p > 0.05), but it was clinically variable (SD $3.89^{\circ}$) on the inter-individual level. Conversely, the angle of the SN line to the THL was significantly different from $7^{\circ}$ (p < 0.05). Very low correlation was found between the linear measurements and angular measurements of A-point and B-point (p < 0.01). Conclusions: The NTVL could be a useful reference line for assessing the antero-posterior position of the maxilla and mandible of Korean adult patients in NHP and CR.

Locus of control of surgical-orthodontic patient (수술-교정 치료 환자의 통제 소재)

  • Lee, Shin-Jae;Ahn, Sug-Joon;Baek, Seung-Hak;Kim, Tae-Woo;Chang, Young-Il;Yang, Won-Sik;Suhr, Cheong-Hoon;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.235-240
    • /
    • 2002
  • Surgical-orthodontic treatment is an increasingly more common dental procedure whose unique psycho-social or psychological feature has not been fairly quantified objectively. Since the treatment of a surgical-orthodontic (or orthodontic) patient is part science and part art, a subjective recognition of a patient about his or her own treatment may be more important than technical success during and after treatment. Therefore, the knowledge of the patient's underlying psychological status could be useful in the prediction of patient's response to surgical-orthodontic (or orthodontic) treatment. The purpose of this study was to investigate and evaluate the psychological difference between conventional orthodontic patient and surgical-orthodontic patient by using locus of control (LOC) examination. Locus of control scale has been proven to be extremely useful in the prediction of a variety of human behaviors. Two types of locus of control data (I-score, Internal locus of control score : I-score, External locus of control score) were obtained for 42 surgical-orthodontic patients and randomly selected 42 conventional orthodontic patients (as a control group) matched for age and gender. No statistically significant difference was observed in the scale of internal and external locus of control between the groups of surgical-orthodontic patients and conventional orthodontic patients. However, in the group of surgical-orthodontic patients, males showed lower E-score (external locus of control score, higher internal locus of control tendency) than females. The results of this study suggested that the psychological background of surgical-orthodontic patients, in contrast with that of cosmetic surgery patients, has a similar disposition with that of orthodontic patients.

A PHOTOELASTIC STUDY ON THE STRESS DISTRIBUTION OF THE UPPER ANTERIOR TEETH WHEN RETRACT WITH HIGH PULL J-HOOK HEADGEAR (상악전치의 후방견인시 J-hook headgear의 사용이 응력분포변화에 미치는 영향에 대한 광탄성학적 연구)

  • Lee, You-Jin;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.697-709
    • /
    • 1997
  • This study was designed to investigate the stress intensity and distribution produced by 1mm activation of retraction archwire with $0^{\circ},\;7^{\circ},\;14^{\circ}$ torque and application of high polk J-hook headgear during retraction of four maxillary incisors using the photoelastic stress analysis. The photoelastic model was made with a PL-3 type epoxy resin which was substituted by alveolar bone portion. Each retraction archwire was fabricated from .020' X .025' stainless steel wire which had vertical loops in 7mm height and hooks for high pull J-hook headgear between central and lateral incisors. The high pull J-hook headgear was applied 35 degree backward and upward to occlusal plane with 200gm pet each side The findings of this study were as follows: 1. In case of $0^{\circ}$ torque, the stress was distributed from cervical 1/8 to apex of roots of central and lateral incisors which were the forms of arc mode. When the high pull J-hook headgear was applied, the stress distributed by arc mode was presented from cervical 1/2 to apex of roots of central and lateral incisors. And the stress distributed by following the root surface was presented from alveolar crest to cervical 1/2 of roots of central and lateral incisors. The stress between apecies of central and Lateral incisors was presented also. 2. In case of $7^{\circ}$ torque, the stress distributed by arc mode was presented from cervical 1/2 to apex of roots of central and lateral incisors. And the stress distributed by following the root surface was presented from alveolar crest to cervical 1/2 of roots of central and lateral incisors. When the high pull J-hook headgear was applied, the stress distributed by following the root surface was presented mote apically than without headgear. The stress between apecies of central and lateral incisors was presented also. 3. In case of $14^{\circ}$ torque, the stress distributed by following the root surface was Presented from alveolar crest to apex of roots of central and lateral incisors. When the high pull J-hook headgear was applied, the stress distributed by following the root surface was presented stronger than without headgear The stress between apecies of central and lateral incisors was presented also.

  • PDF

Comparison of analysis of the lateral cephalogram and analysis of lateral facial photograph (측모 두부방사선계측사진 분석과 측모 사진 분석의 비교)

  • Lim, Sung-Hoon;Cho, Ju-Young;Choi, Gab-Lim;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.74-83
    • /
    • 2006
  • Analysis of lateral cephalometric radiograph (cephalogram) has been used routinely to evaluate skeletal and dental relationships, but analysis of the lateral facial photograph has not been used frequently for evaluation of skeletal relationships. As concerns about harm of X-ray irradiation increases, this study was planned to evaluate the possibility of substituting analysis of the lateral cephalogram with analysis of the lateral facial photograph by comparing these two analyses. According to the ANB values from cephalometric analysis, subjects were divided into three groups: Class I malocclusion group (n=32). Class II malocclusion group (n=32), and Class III malocclusion group (n=31). After measurements of angles indicating horizontal and vertical relationships of the maxilla and mandible on the lateral cephalograms and photographs, differences between Class I, II and III groups were evaluated. To evaluate the similarity between two similar values in the cephalograms and photographs, t-test using standardized variable Z and correlation analysis were performed in the Class I malocclusion group. The results showed that 1) SnN'Pg' on the photograph can be used to evaluate the antero-posterior relationship of the maxilla and mandible (ANB), 2) N'-Sn/Sn-Pg' on the photograph can be used to evaluate facial convexity (NA/APg), 3) Sn-Tra-Me' on the photograph can be used as a measurement similar to FMA. In conclusion, partly substituting lateral cephalogram analysis with lateral facial photograph analysis was possible in the evaluation of the maxilla and mandible.

EFFECT OF 10% CARBAMIDE PEROXIDE ON DENTIN (상아질에 대한 10% Carbamide peroxide가 미치는 영향)

  • Seo, Sang-Woo;Kown, Yong-Hoon;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Kyo-Han;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.423-430
    • /
    • 2003
  • The teeth bleaching with bleaching agent is widely used at recent times. Until yet the exact mechanism of the bleaching agent isn't known but it is thought that is by the complex reduction-oxidation reaction of the decomposed free radical from bleaching agent through various ways. In other words, it is supposed that the teeth are whitened by agent's changing chemical structures of stain-causing materials. The purpose of this study is to exam the change of the dentinal character by bleaching agent and to evaluate the safety of this agent. For this study, after applying 10% carbamide peroxide to enamel of human premolar for 6 hours a day for 2 weeks we examined changes of surface morphology, microhardness, composition and contents of minirals in human dentin using SEM, microhardness tester, FT-Raman spectrometer and EPMA and got following results. There was no significant difference in surface morphologic change when we examined the effect of 10% carbamide peroxide which penetrated into dentin after applied on enamel surface comparing with result from specimen in distilled water No change was shown on the surface of peritubular and intertubular dentin within the nanometeric range. The microhardness between bleached teeth and teeth stored in distilled water showed no statistically significant difference FT-Raman spectra of dentin exhibited no change of the component in human dentin. Only the least change in peaks of organic and inorganic materials were detected in Raman intencity. The total content of mineral elements in dentin with no treatment, stored only in distilled water and stored in distilled water after bleaching were $98.73{\pm}1.89,\;98.56{\pm}2.11\;and\;97.47{\pm}2.51$ respectively. Also they showed no statistically significant difference. From above results, the effect of 10% carbamide peroxide bleaching on structure of dentin is very low and the results may confirm the safety of this bleaching agent.

  • PDF

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF

STRESS DISTRIBUTION IN ESTHETIC ORTHODONTIC BRACKETS : AN ANALYSIS USING THE FINITE ELEMENT METHOD (유한요소 분석을 통한 심미적 교정 브라켓의 응력 및 구조분석에 관한 연구)

  • Lee, Won-You;An, Ju-Sam;Park, Young-Cheol;Park, Myeong-Kyun;Sohn, Hong-Bum;Jeong, Si-Dong
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.43-49
    • /
    • 1998
  • The aim of this study were to measure and compare the stress level on three type brackets and each other material (stainless steel, ceramic) with tipping and torquing forces by using the finite element analysis and to design biomechanically favorable brackets. For this study, three kinds of brackets were selected(A:Transcend-RMO, B:Signature-Unitek, C:PAW: plain archwire appliance-applied for a patent in Yonsei Udiversity). The slot size of bracket was 0.022inch and the size of archwire was 0.0175x0.025inch and taper shaped archwire was used in PAW. Loading force in tipping was 4.27N and torquing force was 32.858N applied by archwire torsion with 19.7degree and 11.3 degree in C type bracket. The conclusions were that (1) The finite element method proved to be a useful tool in the stress analysis of orthodontic bracket subjected to various forces. (2) With tipping, the stresses were concentrated at the gingival wall of the wire slot where it meets the mesial bracket surface and the incisal wall of the wire slot where it meets the distal bracket surface and with torquing, the stresses were concentrated at the junction of the gingival or incisal wall and base of the slot. (3) The maximum stress value was higher in torquing force than tipping force and therefore it is desirable to design on the basis of torquing force. (4) It was considered that the change in material might be affect on the diminish of stress value in the place of stess concentration. (5) The maximum stress value was highest on PAW bracket when the tipping and torquing force was applied and therefore it would be desirable to use mechanically favorable material on PAW bracket.

  • PDF

A STUDY ON METAL RELEASE OF TIN ION-PLATED STAINLESS STEEL ORTHODONTIC APPLIANCES (TiN 피막 처리된 스테인레스강 교정용 장치물의 금속 유리에 대한 연구)

  • KIM, Myung-Sook;Sung, Jae-Hyun;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.43-54
    • /
    • 1995
  • This study was conducted to examine the metal release of TiN-plated stainless steel orthodontic appliances by constructing the simulated orthodontic appliances equivalent to maxillary half arch, by dividing into TiN-plated and TiN-nonplated Bloops and by dividing again these groups into welded and nonwelded groups. And then, the total quantity of metal release was obtained by measuring the amounts of both soluble and precipitated nickel and chromium after immersing in artificial saliva for 15 days. And then, the corrosion appearance of surface structure was observed by using SEM. The results of this study were summarized as follows. 1. The total amounts of released nickel and chromium showed that the TiN-plated group after welding(Group 1) was 25.46 ${\mu}g$, respectively, and 17.4 ${\mu}g$, while the TiN-nonplated group after welding(Group III) was 54.69 ${\mu}g$, respectively, and 85.27 ${\mu}g$. Then, the TiN-Plated group indicated less amounts of metal release(p<0.05). 2. The total amounts of the TiN-plated group without welding(Group II) was 0.05${\mu}g$ and 0.34${\mu}g$, respectively. Then, it was shown that the TiN-plated group without welding(Group II) indicated less metal release than that of the TiN-Plated group after welding(Group I)(p<0.01, p<0.05). 3. When observing their surface structure, there were a lot of precipitate and pitting corrosion in the groups with welding(Group I & III), when the TiN-plated group(Group I) showed lower level than the TiN-nonplated group(Group IIII). On the other hand, the groups without welding(Group II & IV) indicated a little of pitting corrosion. 4. In case of observation with the naked eyes, it was shown that there were significant disco1oration and corrosion in the groups with welding(Group I & III), while there was no any remarkable change in the groups without welding(Group II & IV).

  • PDF

Changes of root lengths and crestal bone height In nail biting patients (손톱 깨물기 습관을 가진 아동의 전치부 치근길이와 치조골 높이 변화에 관한 연구)

  • Hwang, Chung-Ju;Kim, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.689-698
    • /
    • 1999
  • Although the purpose of orthodontic treatment is to increase the function and aesthetics of the jaws as well as to increase stability, there are side effects from the treatment itself such as root resorption and alveolar bone resorption. Such resoiption of the apical root is unpredictable and may even proceed into the dentin layer. Once the process has begun, it is irreversible. By evaluating the effects of different oral habits, especially that ef nail biting, and their correlation with the root and the periodontal tissues, the appropriate biomechanics for orthodontic treatment can be taken into consideration. The possibility of root resorption and alveolar bone loss during orthodontic treatment can also be considered. Also, any legal problems that might occur may be pondered as well. Among the male md female patients of the ages 10~15, 63 were chosen as the test group with known nail biting habits at time of examination and within the same age range those without nail biting habits as the control group. The test group was composed of 30 males and 33 females. The control group had 31 males and 32 females. The result from this study were as follows : 1. Of the 63 patients of both the test and control groups, the male-to-female-ratio was 1:1, and had no statistically significant difference in male and female root resorption. 2. In comparing crown length of the test and control groups, no significant difference existed, but in root length, maxillary and mandibular right and left central incisors and mandibular right lateral incisors had a smaller value. (p<0.001) 3. Average crown-to-root ratio of the test group on the periapical view show a noticeably high value for the maxillary and mandibular right and left central incisors and mandibular right and left lateral incisors. (p<0.01) 4. In comparing and evaluating the alveolar bone loss measured from the cemento-enamel junction to the alveolar bone crest, mesial surfaces of the maxillary and mandibular right and left central incisors and distal surface of maxillary right central incisor of the test group showed greater loss of crestal bone than the control. (p<0.05)

  • PDF

Fracture resistance of zirconia and resin nano ceramic implant abutments according to thickness after thermocycling (지르코니아와 레진나노세라믹 임플란트 지대주의 두께에 따른 열순환 후 파절저항)

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.144-150
    • /
    • 2017
  • Purpose: The aim of this in vitro study is to investigate load bearing capacity of esthetic abutments according to the type of material and wall thickness. Materials and methods: 70 specimens equally divided into seven groups according to their abutment wall thicknesses. The abutments prepared with titanium 0.5 mm wall thickness were used as a control group (Ti-0.5), whereas zirconia abutments and resin nano ceramic abutments with wall thickness 0.5 mm, 0.8 mm and 1.0 mm were prepared as test groups (Zir-0.5, Zir-0.8, Zir-1.0 and RNC-0.5, RNC-0.8, RNC-1.0). All specimens were tested in a universal testing machine to evaluate their resistance to fracture and all of them underwent thermo-cycling before loading test. Mean fracture values of the groups were measured and statistical analyses were made using two-way ANOVA. Results: Zir-1.0 showed the highest mean strength ($2,476.3{\pm}342.0N$) and Zir-0.8 ($1,518{\pm}347.9N$), Ti-0.5 ($1,041.8{\pm}237.2N$), Zir-0.5 ($631.4{\pm}149.0N$) were followed. The strengths of RNC groups were significantly lower compared to other two materials (RNC-1.0 $427.5{\pm}72.1$, RNC-0.8 $297.9{\pm}41.2$) and the strengths of all the test groups decreased as the thickness decreases (P < .01). RNC-0.5 ($127.4{\pm}35.3N$) abutments were weaker than all other groups (P < .05). Conclusion: All tested zirconia abutments have the potential to withstand the physiologic occlusal forces in anterior and posterior regions. In resin nano ceramic abutments, wall thickness more than 0.8 mm showed the possibility of withstanding the occlusal forces in anterior region.