• Title/Summary/Keyword: 치과용 임시 보철물

Search Result 22, Processing Time 0.018 seconds

Complete mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and dental CAD-CAM (완전 무치악 환자에서 임시 의치와 치과용 CAD-CAM을 활용한 전악 고정성 임플란트 회복 증례)

  • Jeon, Sol;Yoon, Hyung-In;Lee, Jae-Hyun;Yeo, In-Sung Luke;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.100-109
    • /
    • 2022
  • Installation of dental implants at optimal angles and positions is critical in long-term stable implant-supported restorations. Surgery and prosthodontic procedures should be performed accurately as the treatment is planned. In this clinical case, Computer aided design and manufacturing technology was used not only to establish a precise surgical plan, but also to fabricate both provisional and definitive fixed prostheses. A surgical guide was designed to install the implants at proper positions for the definitive prostheses. The patient's esthetic information, which was necessary for the new provisional and definitive fixed prostheses, was obtained from the existing temporary dentures. Finally, the complete mouth fixed implant-supported rehabilitation using monolithic zirconia provided the patient with functionally and esthetically satisfactory prostheses.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

원내에서 5축 밀링기로 가공한 PMMA temporary crown의 다양한 임상적 활용

  • Suh, Sangjin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.2
    • /
    • pp.68-83
    • /
    • 2017
  • With the increasing popularity of dental CAD / CAM, the kinds of materials that can be used and the range that can be utilized are also increasing. One of the biggest advantages of a dental CADCAM is that you can make a final prosthesis with one visit, but in case of zirconia or a complex aesthetic prosthesis, it is often difficult to make it in one day. In this case, temporary PMMA material can be used to provide a temporary crown with aesthetic and functional properties to the patient and can be used as a test crown or template for the final prosthesis. And if you are with a 5-axis milling machine in a clinic, you can make a temporary crown precisely to a large extent in a short time. In this article, various applications and clinical cases of PMMA temporary crown in the clinic will be presented.

Mounting and utilization of provisional prostheses on master cast for the fabrication of fixed implant-supported prostheses: a case report (임플란트 고정성 보철 수복 시 임시 보철물의 주모형 마운팅 및 활용: 증례보고)

  • Seong Jo Yu;Jae Jun Ryu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.4
    • /
    • pp.349-356
    • /
    • 2024
  • The restoration process for patients with collapsed occlusion or those requiring extensive rehabilitation often involves various trials and errors. Accurately transferring the patient's oral information to the articulator is key to producing esthetically pleasing and stable prostheses. This necessitates precise master model fabrication and accurate jaw relation records. For patients undergoing extensive implant-supported fixed prostheses, several techniques for recording the jaw relationship are available, including the use of record bases with wax rims, bite blocks with temporary abutments and pattern resin, or provisional prostheses. Among these, using provisional prostheses directly for mounting on the master model can help minimize errors during the jaw relation recording phase. The patient in this case was a 55-year-old female patient, who presented for implant-supported fixed prosthetic rehabilitation. She exhibited multiple tooth loss due to periodontal disease, necessitating comprehensive mouth rehabilitation involving extractions and implant placements. After evaluating esthetics and occlusion with provisional prostheses, the same provisional prostheses were used for mounting on the master model, which enabled the fabrication of customized implant abutments and zirconia prostheses. The final result was a successful restoration, both esthetically and functionally.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

Full mouth rehabilitation of edentulous patient with fixed implant prosthesis (고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례)

  • Shi, Hee-Hyun;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.147-156
    • /
    • 2021
  • There are various treatment options such as conventional complete denture, hybrid prosthesis and implant-supported fixed prosthesis for fully edentulous patients. In case of implant-supported fixed prosthesis, compared to removable prosthesis, it is difficult to place the implant in the correct position considering the anatomical contours of the final prosthesis. In this case, a full mouth rehabilitation with implant-supported fixed prosthesis was performed for a patient who required extraction of all remaining teeth due to dental caries and chronic periodontitis. In the implant placement stage, the implant was placed in the desired position using a surgical guide fabricated considering the anatomical contours of the final prosthesis, and the function and esthetics were evaluated through correction and re-fabrication of the fixed provisional restoration. A final restoration of porcelain fused to gold prosthesis was delivered to the patient based on the provisional restoration. To cope with complications such as loosening of screws and fracture of porcelain, a screw-retained type prosthesis was fabricated for the posterior part and a screw-cement-retained type prosthesis for the anterior part. As a result, the patient showed an improved prognosis in terms of functional and esthetics after the final prosthesis was delivered.

Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report (만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례)

  • Min-Jae Park;Ji-Won Bang;Joo-Hyuk Bang;Seon-Young Lim;Yong-Sang Lee;Keun-Woo Lee;Sung-Yong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.104-112
    • /
    • 2024
  • When teeth are extracted, patient face social, psychological and aesthetic problems which can be minimized by fabricating a interim immediate denture. Interim immediate denture manufactured using digital technology can be completed with reduced number of patients' visits and simple laboratory process. Implant-supported removable partial denture (ISRPD) has been suggested as alternative treatment option when fixed implant prosthesis is not feasible. In this case, interim immediate dentures were fabricated using digital technology for patient after teeth extraction and treatment using ISRPD by installing implants and surveyed crowns is found to be successful with better support, stability and maintenance of removable partial dentures.

Comparison of shear bond strength between various temporary prostheses resin blocks fabricated by subtractive and additive manufacturing methods bonded to self-curing reline resin (절삭 및 적층 가공법으로 제작한 임시 보철물 레진 블록과 재이 장용 자가중합 레진의 전단결합강도 비교)

  • Hyo-Min Ryu;Jin-Han Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.189-197
    • /
    • 2023
  • Purpose. This study aimed to compare and evaluate the shear bond strength between various temporary prostheses resin blocks fabricated by subtractive and additive manufacturing methods bonded to self-curing reline resin. Materials and methods. The experimental groups were divided into 4 groups according to the manufacturing methods of the resin block specimens and each specimen was fabricated by subtractive manufacturing (SM), additive manufacturing stereolithography apparatus manufacturing (AMS), additive manufacturing digital light processing manufacturing (AMD) and conventional self-curing (CON). To bond the resin block specimens and self-curing resin, the reline resin was injected and polymerized into the same location of each resin block using a silicone mold. The shear bond strength was measured using a universal testing machine, and the surface of the adhesive interface was examined by scanning electron microscopy. To compare between groups, one-way ANOVA was done followed by Tukey post hoc test (α = 0.05). Results. The shear bond strength showed higher values in the order of CON, SM, AMS, and AMD group. There were significant differences between CON and AMS groups, as well as between CON and AMD groups. but there were no significant differences between CON and SM groups (P > .05). There were significant differences between SM and AMD groups, but there were no significant differences between SM and AMS groups. The AMS group was significantly different from the AMD group (P < .001). The most frequent failure mode was mixed failures in CON and AMS groups, and adhesive failures in SM and AMD groups. Conclusion. The shear bond strength of SM group showed lower but not significant bond strength compared to the CON group. The additive manufacturing method groups (AMS and AMD) showed significantly lower bond strength than the CON group, with the AMD group the lowest. There was also a significant difference between the AMD and SM group.

Oral rehabilitation of a patient with collapsed occlusal plane resulting from loss of posterior teeth (구치부 상실로 인해 교합 평면이 기울어진 환자에서 임플란트를 이용한 구강 회복 증례)

  • Jinwoo Han;Jae-Seung Chang;Se-Wook Pyo;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.165-173
    • /
    • 2024
  • Restoring lost teeth is very important in terms of both function and aesthetics. If tooth loss occurs in the posterior region and the loss of support is persistent, it may cause a gradual shift in the position of the mandible and a change in occlusion. This clinical case attempted to restore support for the posterior teeth with a fixed prosthesis using implants in a patient whose opposing teeth were erupted and the occlusal plane collapsed due to long-term loss of the maxillary left posterior teeth and mandibular right first molars. To correct the occlusal plane of remaining dentition, wax-up of maxillary left posterior teeth was duplicated with acrylic resin and placed on maxilla. Surgical template for implant placement were fabricated using digital technology. After the support of the posterior teeth was restored with the placement of the implant, stable occlusion with temporary restorations was observed for a sufficient time. Afterwards, monolithic zirconia prosthesis was placed on the patient to ensure functional and aesthetic improvement.