• Title/Summary/Keyword: 치과용 복합레진 수복

Search Result 70, Processing Time 0.022 seconds

PROPOSAL OF NEW DENIAL COLOR-SPACE FOR AESTHETIC DENIAL MATERIALS (치과용 심미 수복 재료들의 색상 연구를 통한 새로운 치과용 색체계의 제안)

  • Oh, Yun-Jeong;Park, Su-Jung;Kim, Dong-Jun;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • The purpose of this study is to develope new dental color-space system. Twelve kinds of dental composites and one kind of dental porcelain were used in this study. Disk samples (15 mm in diameter, 4 mm in thickness) of used materials were made and sample's CIE $L^*a^*b^*$ value was measured by Spectrocolorimeter (MiniScan XE plus, Model 4000S, diffuse/$8^{\circ}$ viewing mode, 14.3 mm Port diameters, Hunter Lab USA) The range of measured color distribution was analyzed. All the data were applied in the form of T### which is expression unit in CNU Cons Dental Color Chart. The value of $L^*$ lies between 80.40 and 52.70. The value of $a^*$ are between 10.60 and 3.60 and $b^*$ are between 28.40 and 2.21. The average value of $L^*$ is 67.40, and median value is 67.30. The value of $a^*$ are 2.89 and 2.91 respectively. And for the $b^*$, 14.30 and 13.90 were obtained. The data were converted to T### that is the unit count system in CNU-Cons Dental Color Chart. The value of $L^*$ is converted in the first digit of the numbering system. Each unit is 2.0 measured values. The second digit is the value of $a^*$ and is converted new number by 1.0 measured value. For the third digit $b^*$ is replaced and it is 2.0 measured unit apart. T555 was set to the value of $L^*$ ranging from 66.0 to 68.0, value of $a^*$ ranging from 3 to 4 and $b^*$ value ranging from 14 to 16.

Evaluation of Flexural strength and surface porosity of three indirect composite resins (3종의 간접수복용 복합레진의 굴곡강도 비교 및 표면관찰)

  • Kim, Jun-Tae;Park, Jin-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate flexural strength, composite surface and fractured surface of three different indirect composite resins. Methods: Fifteen bar-shaped specimens ($25mm{\times}2mm{\times}2mm$) were fabricated for each FL group (Flow type and Light curing) and PLP group (Putty type and Light, Pressure curing) and PL group (Putty type and Light curing) according to manufacturer's instructions and ISO 10477. Fabricated specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending strength test was performed to measure flexural strength using universal testing machine at a crosshead speed of 1mm/min (ISO 10477). Surface and fractured surface of specimens were observed by digital microscope. Results were analyzed with Kruskal-wallis tests (${\alpha}=0.05$). Results: Mean (SD) of three different indirect composite resins were 83.38 (6.67) MPa for FL group, 139.90(16.53) MPa for PLP group and 171.72(16.74) MPa for PL group. Flexural strength were statistically significant (p<0.05). Differences were not observed at fractured surface among three groups. However, many pores over $100{\mu}m$ were observed at PL group in observing surface of specimen. Conclusion: Flexural strength of composite resins was affected by second polymerization method and content of inorganic filler.

REMINERALIZATION EFFECTS OF GLASS IONOMER RESTORATIONS ON ADJACENT INTERPOXIMAL-A MICROTOMOGRAPHIC STUDY (미세전산화 단층 촬영을 이용한 글라스 아이오노머 수복의 인접면 재광화 효과에 대한 연구)

  • Lee, Hyeok-Sang;Lee, Sang-Dae;Kim, Jung-Wook;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.474-480
    • /
    • 2004
  • The purpose of this in vitro study was to compare the remineralizing effects of three glass ionomer cements (high filled glass ionomer cement, compomer, resin modified glass ionomer cement) with resin composite (control group) on incipient interproximal caries, and to assess long-term change of remineralization effect, in each material, evaluated by microtomography. Proximal restoration was simulated with tooth specimen and Glass Ionomer Cements. And each of these groups was placed into a closed container with artificial saliva at $37^{\circ}C$ and pH 7.0 for a time period of thirty days with constant circulation. At the end of thirty and sixty days, tomographic images were taken from these specimens with micro CT scanner. Materials used in this study were as follows. Group 1: Fuji IX GP (GC Corp., Tokyo, Japan) Group 2: Vitremer (3M ESPE, St. Paul, Minn., USA) Group 3: F2000 (3M ESPE, St. Paul, Minn., USA) Group 4: Z250 (3M ESPE, St. Paul, Minn., USA) Using density-measuring program, the micro-density of carious lesions on the specimens were measured. The mean density changes of each group were compared to the other groups to evaluate the effect of remineralization. The results were as follows: 1. The lesion density of all groups increased. 2. The mean density increase of Group 1, 2, 3 were higher than that of Group 4 every month(p<0.05). 3. There were significant differences of density increase among glass ionomer group(Group 1, 2, 3).

  • PDF

DIRECT PULP CAPPING WITH BONDING RESIN (접착용 레진을 이용한 유치의 직접 치수복조술에 관한 연구)

  • Cho, Hae-Sung;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.165-172
    • /
    • 2006
  • A direct pulp capping with different medicaments has been attempted for a long time. The most commonly used among those is the calcium hydroxide. In primary teeth, however, a success rate of direct pulp capping with calcium hydroxide has been reported to be lower than that of pulpotomy. The disappointing results of calcium hydroxide have prompted the search for other capping materials. Lately, several researchers suggested an application of adhesive resin-based composite systems as a capping material. They claimed that when an exposed vital pulp is capped directly with bonding resin, the pulp tissue is free of inflammation or necrosis without clinical symptoms. The aim of this study was to compare short-term effects of the bonding resin which was applied on the mechanically exposed vital pulp tissue and those of direct pulp capping with calcium hydroxide. The second objective was to compare success rates of the primary teeth which already underwent physiologic root resorption and those of the teeth which had not undergone physiologic root resorption yet, in each capping material groups. The vital, healthy pulp of forty-one primary teeth were exposed mechanically during a cavity preparation. They were divided into two groups: Group 1(n=21) underwent capping with bonding resin, and group 2(n=20) underwent capping with calcium hydroxide. Then these two groups were subdivided into two groups in each : the teeth which show physiologic root resorption and the teeth without root resorption. All of the sample teeth were restored with composite resin. Clinical evaluations such as percussion test, ice test, EPT, were recorded and also before- and after- standard x-ray films were compared and evaluated to decide whether the case was successful or not. Evaluation was performed at least 3 months after the capping materials. The results were as follows 1. There was no difference in success rate between group 1 and group 2. 2. Success rate of the teeth with physiologic root resorption was higher than that of the teeth without physiologic root resorption in group 1 and group 2. 3. There was no difference in success rate between anterior teeth and posterior teeth.

  • PDF

COLOR STABILITY OF THE RESIN CEMENTS WITH ACCELERATED AGING (레진시멘트의 색안정성에 대한 가속시험)

  • Song, Ha-Jeung;Park, Su-Jung;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.389-396
    • /
    • 2008
  • The purpose of this study was to evaluate the color stability of resin cements with accelerated test. Four dual curing resin cements: Panavia-F (KURARAY). Duolink (BISCO), Variolink-II (Ivoclar Vivadent), and RelyX Unicem (3M ESPE) and 1 self curing resin cement: Resiment CE (j. l. Blosser) were used in this study. In control group, Gradia Anterior (GC) composite resin and Tescera Dentin (Bisco) indirect composite were used. Ten disk shape specimens were made from each resin cement. The specimens were subjected to an accelerated aging process in a refrigerated bath circulator at 60$^{\circ}C$ for 15 and 30 days. Spectrophotometric analyses were made before and after 15 days and 30 days of accelerated aging time. The color characteristics ($L^*,\;a^*,\;b^*$) and the color difference (${\Delta}E^*$) of the specimens before and after immersion were measured and computed. Regardless of type of the resin cements, $L^*$ value was decreased and $a^*$ value was increased, but there were no significant difference. But $b^*$ value was increased significantly (p < 0.05). Tescera inlay showed least color change (p < 0.05), but Gradia showed notable color change after 15 days. After 30 days on accelerated aging, ${\Delta}E^*$ value was increased (Panavia-F < Variolink-II < Resiment CE < Duolink < Unicem) (p < 0.05). but there were no significant difference among Panavia-F, Variolink-II, and Resiment CE groups. After 30 days of accelerated aging, ${\Delta}E^*$ value of all resin cements were greater than 3.0 and could be perceived by the human eye.

THE COMPARISON OF RELATIVE RELIABILITY ON BIAXIAL AND THREE POINT FLEXURAL STRENGTH TESTING METHODS OF LIGHT CURING COMPOSITE RESIN (광중합형 레진의 3점 굴곡 강도와 이축 굴곡 강도 측정 방법에 대한 상대적 신뢰도의 비교)

  • Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.58-65
    • /
    • 2006
  • The possibility of applying a hi-axial flexure strength test on composite resin was examined using three point and hi-axial flexure strength tests to measure the strength of the light-cured resin and to compare the relative reliability using the Weibull modulus. The materials used in this study were light-curing restorative materials, $MICRONEW^{TM},\;RENEW^{(R)}$ (Bisco, Schaumburg, USA). The hi-axial flexure strength measurements used the piston-on-3-ball test according to the regulations of the International Organization for Standardization (ISO) 6872 and were divided into 6 groups, where the radius of the specimens were 12mm (radius connecting the 3-balls: 3.75mm), 16 mm(radius connecting the 3-balls: 5mm), and the thickness were 0.5mm, 1mm, 2mn for each radius. The hi-axial flexure strength of the $MICRONEW^{TM}\;and\;RENEW^{(R)}$ were higher than the three point flexure strength and the Weibull modulus value were also higher in all of the bi-axial flexure strength groups, indicating that the hi-axial strength test is relatively less affected by experimental error. In addition, the 2 mm thick specimens had the highest Weibull modulus values in the hi-axial flexure strength test, and the $MICRONEW^{TM}$ group showed no significant statistical difference (p>0.05). Besides the 2mm $MICRONEW^{TM}$ group, each group showed significant statistical differences (p<0.05) according to the thickness of the specimen and the radius connecting the 3-balls. The results indicate that for the 2mm group, the hi-axial flexure strength test is a more reliable testing method than the three point flexure strength test.

AN EVALUATION OF MECHANICAL PROPERTIES OF LIGHT-CURED RESTORATIVE COMPOSITES BY INDENTATION AND COMPRESSION TEST (압입과 압축에 의한 광중합형 수복용 복합레진의 기계적 성질 평가)

  • Lee, Yong-Woo;Yu, Mi-Kyung;Cho, Young-Gon;Bae, Tae-Sung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.511-518
    • /
    • 1999
  • This study was performed to evaluate the mechanical properties of light-cured restorative composites by compression and indentation tests. Five commercially available light-activated composites (Heliomolar : HM, Aelitefil : AF, Amelogen : AG, Clearfil AP-X : CF, Z100 ZH) were used Disc specimens of 12mm in diameter and 1 mm in thickness and Cylindrical specimens of 3mm in diameter and 6mm in length were prepared for the indentation and compressive test, respectively. All specimens were immersed in distilled water at $37^{\circ}C$ for 30 days. An indentation test of 68-degree trigonal diamond pyramid was made under 10 g load for 15 seconds and an Knoop indentation test was made under 50 g load for 15 seconds. Hardness numbers, characteristic indentation depths and permanent deformation were measured during indentation of the 68-degree trigonal diamond pyramid compressive test was carried out at a crosshead speed of 0.5mm/min. The results obtained were summarized as follows, 1. The highest hardness value was obtained in the CF group and the lowest value was obtained in the HM group. Hardness values showed no significant, difference between AG group and HM group but other groups showed the significant differences in each group(p<0.05). 2. Hardness number by Knoop pyramid were higher than those of 68-degree trigonal diamond pyramid. 3. Plastic deformation during the indentation of 68-degree trigonal diamond pyramid was the lowest in the CF group and the largest in the HM group. Results of Tukey test showed the significant difference between CF group and others; also between ZH and AF groups and AG and HM groups(p<0.05) 4. The highest compressive strength was obtained in the CF group and the lowest compressive strength was obtained in the ZH group. Compressive strength values showed no significant difference between CF group and ZH group but other groups showed the significant differences in each group(p<0.05).

  • PDF

A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA (분광광도계를 이용한 커피와 인공타액에서의 수복용 복합레진의 변색에 대한 연구)

  • Eom, Seung-Hee;Cho, Hyo-Sun;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.530-545
    • /
    • 1996
  • The purpose of this study was to investigate by spectrophotometry the changes in color parameters of composite resins after exposure to distilled water, filtered coffee, and artificial saliva. Five kinds of fine particle composite resin in experiment 1, and six kinds of composite resin in experiment 2 were used. In experiment 1, each group of composite resin was stored in distilled water at $4^{\circ}C$, $50^{\circ}C$, and filtered coffee solution at $4^{\circ}C$, $50^{\circ}C$. And then each specimen was measured by spectrophotometer. Measurements were repeated in 1 hour, 2 hours, 4 hours, 8 hours, 16 hours, 24 hours, and 48 hours. In experiment 2, all specimens of each brand were stored in distilled water at $37^{\circ}C$, artificial saliva not contained mucin at $37^{\circ}C$, and artificial saliva contained mucin at $37^{\circ}C$. All specimens of each brand were measured by spectrophotormeter in 1 week, 2 weeks, 4 weeks, 8 weeks, and up to 12 weeks. The results were as follows : 1. In cold coffee, five of fine particle composite resins showed ${\Delta}E{^*}_{ab}$ values less than 2. However, in hot coffee ${\Delta}E{^*}_{ab}$ values of Amelogen Universal and Prisma TPH were higher than those of Conquest Crystal, ${\AE}$litefil and Z100. 2. Z100 and ${\AE}$litefil had better cleansibility of extrinsic coffee staining than Amelogen Universal, Conquest Crystal and Prisma TPH. 3. In distilled water and artificial saliva not contained mucin, five of fine particle composite resin showed ${\Delta}E{^*}_{ab}$ values less than 2 up to 12 weeks. However, Silux Plus showed higher than ${\Delta}E{^*}_{ab}$ values of fine particle composite resin. 4. As an immersion solution for discoloration experiment, artificial saliva not contained mucin showed similar appearance as distilled water. However, artificial saliva contained mucin had different appearance from the others. 5. In artificial saliva contained mucin, ${\AE}$litefil, Prisma TPH and Z100 showed ${\Delta}E{^*}_{ab}$ values less than 1 up to 12 weeks. However, Silux Plus, Amelogen Universal and Conquest Crystal showed ${\Delta}E{^*}_{ab}$ values more than 1 up to 12 weeks. But, Conquest Crystal showed different characteristics of chromacity difference value(less chromatic) and lightness difference value(lighter) from Silux Plus and Amelogen Universal.

  • PDF

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

A study on the shear bond strengths of orthodontic brackets according to surface treatments and polymerizing techniques. (도재표면의 처리방법과 접착제의 중합방식에 따른 교정용 브라켓의 전단강도의 연구)

  • Kim, Young-Joo;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.445-456
    • /
    • 1999
  • As a result of increased education and communication, the field of orthodontics has recently been expanded to include a greater number of adult treatment procedures. With this increased demand for adult orthodontic treatment, a problem that frequently arises is the placement of appliances on teeth restored with porcelain. But conventional acid-etching is ineffective in the preparation of porcelain surface for mechanical retention of orthodontic attachments. Also, it is possible to damage on porcelain. The purpose of this study was to evaluate the effect of composite bonding materials and the porcelain surface treatment methods on shear bond strength, and to observe the porcelain fracture rates. To accomplish this purpose, this study was carried out with feldsphatic porcelain, Ceram II. Porcelain surface treatment methods were divided into intact glazed porcelain which had not treatment and surface roughening. Surface roughening by etching with Hydroluoric acid(HF), sandblasting with Microetcher II and compound treatment with etching and sandblasting. Bonding materials were Ortho-two and Transbond. All porcelain specimens were applicated with porcelain primer. 1. In comparision according to porcelain surface treatment, surface roughening groups by HF etching and sandblasting had higher shear bond than intact group. No significant difference was found in Transbond group. 2. Ortho-two group had the higher shear bond strength than that of Transbond group in B:.u etching and sandblasting. 3. E(Transbond. Intact)group had the lowest shear bond strength in all experimental group. The bond strength was higher than clinically successful bond strength. 4. Non-treated group had very higher porcelain rates than treated group. 5. This study indicates that porcelain surface-roughening may not be necessary to attachment of orthodontic brackets to porcelain surfaces.

  • PDF