• Title/Summary/Keyword: 치과기공물

Search Result 154, Processing Time 0.027 seconds

전부 무치악테이스의 심미적고려

  • Jo, Seong-Am
    • The Journal of the Korean dental association
    • /
    • v.32 no.3 s.298
    • /
    • pp.211-214
    • /
    • 1994
  • 90년에 접어들어, 임프란트보철물의 금속구조물을 완성하는데 있어서 단순한 wax-up에 의하기 보다는 Gold-cylinder(보철물과 연결되는 귀금속합금원통)주위에 resin으로 이는 resin-wing이라하여 일정한 두께의 Block을 붙여서 상품화하고 있다. 이를 사용하면 기공할때, 두께를 어느정도로 하여야 할까하는 신경을 쓸 필요없이 Resin-sing을 wax로 이어 주기만 하면 된다.

  • PDF

Observation of Occlusal Relations for Production to Dental Prosthetics of Dogs (중형견 치과보철물 제작을 위한 교합관계 관찰)

  • Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.203-208
    • /
    • 2016
  • Purpose: This study introduces the production process of dog's dental prosthesis using an automated dental prosthetics technology. The occlusal interaction of dog's dental prosthesis was observed. Methods: This study was proceeded with dog's the mandibular first molar teeth. The 3D CAD designed to 3D model specimens was observed by CAD software. and The specimens designed to 3D model specimens was observed occlusal interaction by using articulator. Results: Occlusal contact point in prosthetic specimens were observed in buccal surface. and 98% of the size of the crown is the best occlusal relationship. Conclusion: Observation of occlusal relations result to 98% of the size of the crown is the best.

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

An experimental study of repair of porcelain-fused to metal restorations (치과용 도재용착주조관(陶材溶着鑄造冠)의 수리에 대한 실험적 고찰)

  • Kim, Jin-Wan
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.55-59
    • /
    • 1980
  • 이와 같은 세 기술은 많은 도재용착주조관의 수리에 이용된다고 할 수 있고 이런 기술은 완전한 보철물을 다시 만들지 않고 연장된 도재용착주조관의 수리에 적용할 수 있는 것이다. 금속덮개(over casting)와 핀에서 유지를 얻는 금속 전장판에 의한 수리의 성공은 다시 제작한 도재용착주조관의 그것과 비교할 만하다. 그러나 도재에 합성수지(composite resin)를 결합시켜 수리하는 방법은 합성수지(composite resin)가 도재보다 잘 닳을 뿐만 아니라 색깔의 안정성도 좋지 않으며 도재가 금속판에 용착될 때 창조되는 결합력보다 silance bonding agent를 사용하여 창조되는 결합력 즉 화학적 결합(chemical bond)이 약하기 때문에 좋다고 할 수는 없다. 그러므로 silance bond repair에 관한 연구는 앞으로도 여러분들과 함께 더욱 더 연구할 과제가 아닌가 생각되는 바입니다.

  • PDF

Evaluation of clinical adaptation of dental prostheses printed by 3-dimensional printing technology (3D 프린팅 기술로 출력된 치과 보철물의 임상적 적합도 평가)

  • Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Purpose: The objectives of this study was to evaluate clinical adaptation of dental prostheses printed by 3 dimensional(3D) printing technology. Methods: Ten study models were prepared. Ten specimens of experimental group were printed by 3D printing(3DP group). As a control group, 10 specimens were fabricated by casting method on the same models. Marginal gaps of all specimens were measured to evaluate clinical adaptation. Marginal adaptations were measured using silicone replica technique and measured at 8 sites per specimen. Wilcoxon's signed-ranks test was used for statistical analysis(${\alpha}=0.05$). Results: Means of marginal adaptations were $95.1{\mu}m$ for 3DP group and $75.9{\mu}m$ for CAST group(p < 0.000). Conclusion : However, the mean of the 3DP group was within the clinical tolerance suggested by the previous researchers. Based on this, dental prosthesis fabricated by 3D printing technology is considered to be clinically acceptable.

Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system) (개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례)

  • Hong, Tae-Young;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.423-430
    • /
    • 2016
  • The implant prosthesis can be divided into the screw retained prosthesis and cement retained prosthesis. Each type has advantages as well as disadvantages which is unfavorable to maintain the implants. To overcome these drawbacks, T-screw system was developed. T-screw system which utilizes a lingual direction of the screw to retain the implant prosthesis, has advantages of retrievability of the prosthesis, passive fit, and possibility to form esthetic and functional occlusal surface. The prior prosthesis which utilized horizontal screws had difficulty in fabrication especially in the case of multiple units, and also limited use with all-ceramic prosthesis. In this case, fabricating the implant prosthesis by using the T-screw system showed superior results in easy maintenance, esthetics, and also functions. In addition, we are to report the method of using the T-screw system in implant prosthesis, such as multiple units of implant prosthesis and all ceramic prosthesis.

Implant-supported prosthetic rehabilitation for the edentulous maxilla using the additive manufacturing technology: A case report (레이저 적층 제조 기술을 이용한 상악 무치악 환자의 임플란트 고정성 보철 수복 증례)

  • Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.173-178
    • /
    • 2018
  • The direct metal laser sintering (DMLS) technique would be promising for the full-arch implant-supported restorations due to reduced cost and manufacturing time without potential human errors and casting defects. The aims of this case report were to describe the successful outcome of an implant-supported fixed dental prosthesis in the edentulous maxilla by using the DMLS technology and computer-aided design and computer-aided manufacturing (CAD/CAM) monolithic zirconia crowns, and to describe its clinical implications. A healthy 51-year-old Korean woman visited Seoul National University Dental Hospital and she was in need of a rehabilitation of her entire maxilla due to severe tooth mobility. In this case, all maxillary teeth were extracted and an implant-supported fixed dental prosthesis was fabricated that involved a cobalt-chromium (Co-Cr) framework with the DMLS technique and CAD/CAM monolithic zirconia crowns. Six months after delivery, no distinct mechanical and biological complications were detected and the prosthesis exhibited satisfactory esthetics and function. In this case report, with the DMLS system, the three-dimensional printed prosthesis was created without additional manual tooling and thus, reliable accuracy and passive fit were obtained.

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.

A study on ceramic shade prescriptions for work authorizations (도재 보철물 색조의 처방에 관한 고찰)

  • Sung, Hwan-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.177-183
    • /
    • 1988
  • This paper aims to examine ceramic shade prescriptions for work authorizations in all its aspectclincal information, recording information, technical considerations, extended application, practical applications. The results are as follows : 1. The basic application provides essential data for ceramic veneer fabrication. 2.Three-dimensional information divides the space for body and enamel components. 3. The second body shade selection improves shade matching in the middle one-third of the tooth and enhences the appearance of the enamel component. 4. Ceramists are encouraged to recognize the influence each component has upon the total shade composition. 5. A format is established for recording clinical information. 6. The use of available ceramic systems is seemingly unlimited. The method presented provides flexisility for recording the most detailed shade information in simple graphic and verbal terms. 7. Technical simplification is a by-product of complete, precise work information.

  • PDF

The Margin Fit of Nickel-Chromium Metal Alloys used for the Production of Crown and Bridge Prosthetics (치관보철물(齒冠補綴物) 제작(製作)에 사용(使用)되는 Nickel-Chromium계(系) 합금(合金)의 치경부(齒頸部) 변록(邊綠)에 관(關)한 적합성(適合性))

  • Lee, In-Kyu;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.13 no.1
    • /
    • pp.9-13
    • /
    • 1991
  • The purpose of this study was to determine the marginal fit of recasting by used nickel-chromium metal alloys, Hi-Crown, New-Crown and CB-80. Ninety crown prosthetics were divided into eighteen groups according to new to old metal ratios. Each crown was seated on its master die and then the marginal gaps were measured under optical microscope($\times$50). All groups were showed good marginal fit, except group 3 of Hi-Crown(156$\mu$m). The results suggest that the marginal fit of Ni-Cr metal alloy casting bodies were good as without concerned to mixed ratios and metals.

  • PDF