• Title/Summary/Keyword: 측정 프로브

Search Result 340, Processing Time 0.024 seconds

Comparative Study on the Secondary Flow Measurement in a Turbine Cascade Using 5-hole and 7-hole Probes (5공과 7공 프로브를 이용한 터빈 캐스케이드의 이차유동 측정 결과 비교연구)

  • Nho, Young-Cheol;Lee, Yong-Jin;Park, Jung-Shin;Kim, Hark-Bong;Kwak, Jae-Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.5-12
    • /
    • 2010
  • Comparative study on the flow measurement by 5-hole and 7-hole probes was conducted in a linear cascade with tip clearances of 2.3%, 3.1%, and 4.4% of the blade span. Calibration range of the 5-hole and the 7-hole probes were ${\pm}25$ and ${\pm}50$ degrees, respectively. Results show that the secondary flow and total pressure loss measured by the 5e-hole and 7-hole probes were similar at small tip clearance cases. However, at the tip clearance of 3.1% and 4.4% of the blade span cases, flow angles exceeding the calibration range of the 5-hole probe were observed. Because of the wider calibration range, larger flow angle by strong leakage vortex could be measured by the 7-hole probe.

Design and Fabrication of the Ka-band Waveguide to Microstrip Transition using Probe structure (프로브 구조를 이용한 Ka 대역 도파관-마이크로스트립 트랜지션의 설계 및 제작)

  • Kwon, Hyuk-Ja;Lee, Sung-Ju;Jang, Ho-Joon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.7
    • /
    • pp.67-71
    • /
    • 2008
  • We report the waveguide to microstrip transition using probe structure for Ka-band transceiver. The waveguide to microstrip transition is composed of probe, inductive line, ${\lambda}/4$ impedance transformer, and $50{\Omega}$ microstrip line. For design of the transition, we optimized the characteristic impedances and the lengths of the component parts. The fabricated transition exhibits an insertion loss of 1.3 dB and the input/output return losses of below 14 dB between 30 and 40 GHz. The insertion loss of each transition is about $0.5{\sim}0.6dB$, considering the losses in the microstrip line and input/output waveguides.

A Noncontact Optical Sensor Development for Measuring the Thickness of Transparent Plates (투명판의 두께 측정용 비접촉식 광센서 개발)

  • Ryu, Young-Kee;Oh, Choonsuk;Lee, Seoyoung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.1-6
    • /
    • 2006
  • The noncontact optical sensor using the hologram laser and automatic power controller is developed to measure a thickness of transparent objects and achieve excellent performance. Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition the casting glass under high temperature results in extending the size of sensor body. The accuracy of the sensor is degraded due to these reasons. In this paper, to overcome these problems, we proposed a low cost non-contact optical sensor that is composed of a hologram laser unit used for optical pickup of CD player and a plastic lens. Therefore the problems caused by the contact sensor are solved by using the noncontact sensor. The noncontact sensor has to move toward the objects and obtain the focus error signal to measure a position of transparent objects. While the internal temperature of the sensor is controlled under ${\pm}0.1^{\circ}$, many trials shows ${\pm}2{\mu}m$ measurement error as excellent performance.

Effect of Measuring Method on the Evaluation of Piezoelectric and Dielectric Properties of PMN-PT Single Crystal (PMN-PT 단결정의 압전 및 유전 특성 평가에 미치는 측정 방법의 영향)

  • Kim, Yong Soo;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.69-74
    • /
    • 2019
  • The influence of measuring fixtures on the measurement of dielectric and piezoelectric properties of PMN-PT single crystal specimens was investigated. As the pressure of the jig pin which applied the AC electrical signal to the sample decreased, the lower resonance resistance was measured and the higher mechanical quality factor was calculated. The mechanical quality factor was 418 when the spring tension of the jig pin was 20grf, and the value of the quality factor was reduced by half when the spring tension was 200grf. The 4-probe fixture method is unsuitable for measuring piezoelectric properties, but it was suitable for the measurement of dielectric loss. In order to accurately evaluate the piezoelectric properties of PMN-PT, it is necessary to lower the spring tension of the jig pin as much as possible.

SAR Analysis for Test Positions of Mobile Phone (휴대전화의 시험위치에 따른 SAR 분석)

  • 최형도;이애경;조광윤;오학태
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1199-1205
    • /
    • 2001
  • There has been an increase in the public concern about possible health risks by electromagnetic exposure from mobile phones. Recently, several SAR measurement procedures have been proposed to demonstrate the compliance of mobile phone with safety limits. To determine the maximum localized SAR of a test mobile phone, the electric field distribution is measured in the head phantom with simulated tissue liquid using the probe The important parameters in SAR measurement are the E-field probe, the shape and size of phantom, the electrical parameters of simulated tissue liquid, and test position, etc. Therefore, in order to setup the measurement standard, the studies on these factors are required. In this paper, the effects of the maximum localized SAR on the test positions of mobile phones were analyzed by the numerical computation and the SAR measurement. From the results, the worst condition of commonly used positions was determined and the touch and tilted positions were adopted as test positions of the domestic SAR measurement standard.

  • PDF

Pressure Sensitive Adhesion Performances of SIS/SBS based UV-curable Pressure Sensitive Adhesives using Thiol-ene Reaction (Thiol-ene 반응을 이용한 UV경화형 SIS/SBS계 점착제의 점착물성)

  • Lim, Dong-Hyuk;Do, Hyun-Sung;Kim, Hyun-Joong;Yoon, Goan-Hee;Bang, Jung-Suk
    • Journal of Adhesion and Interface
    • /
    • v.6 no.3
    • /
    • pp.19-25
    • /
    • 2005
  • Synthetic rubber based pressure-sensitive adhesives (PSAs) usually containing SIS or SBS block copolymer, tackifier, plasticizer, and other additives are now widely used on various applications. As these PSAs are physically crosslinked and can be applied without the use of solvent, they are thermally processable and environmentally friendly. However these PSAs cannot be used in high temperature applications and in applications where solvent and chemical resistance properties are required. We developed the PSA adding UV curable system, such as thiol-ene system, to increase adhesion properties at elevated temperature. The adhesion properties such as probe tack, peel strength, shear adhesion failure temperature (SAFT) were evaluated. The probe tack test was conducted with varying probe materials and coating thickness of PSAs. Using the contact angle, the surface property of the cured PSAs was also observed.

  • PDF

Millimeter-wave waveguide transducer using extended E-plane probe (연장된 E-plane 프로브를 이용한 밀리미터파 도파관 변환기)

  • Park, Woojin;Choe, Wonseok;Lee, Kookjoo;Kwon, Junbeom;Jeong, Jinho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.159-165
    • /
    • 2018
  • In this paper, a low-loss wideband waveguide transducer is proposed for millimeter-wave communication and radar applications. A conventional E-plane probe transducer is generally designed using thin and flexible substrate at millimeter-wave frequencies, considering the very small waveguide size. However, it results in serious performance degradation caused by the bending of the substrate. In order to alleviate this problem and provide a reliable performance, we propose an extended E-plane probe transducer where the probe substrate is extended to and fix ed in the slit area formed in the waveguide wall. It is fabricated using $127{\mu}m$-thick substrate with dielectric constant of 2.2. The measurement in the back-to-hack configuration shows the excellent insertion loss of 1.35 dB (${\pm}0.35dB$) including the loss of 3 cm-long thru waveguide and return loss better than 13.8 dB over entire W-band (75-110 GHz). Therefore, it can be effectively applied for millimeter-wave high-speed communications and high-sensitivity radars.

Fabrication of Fluorescent Oxygen Sensor Probe Module Based on Planner Lightwave Circuits using UV Imprint Lithography (UV 임프린트 공정을 이용한 평면 광회로 기반 형광 산소 센서 프로브 모듈 제작)

  • Ahn, Ki Do;Oh, Seung hun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.37-41
    • /
    • 2018
  • This paper presents the integrated fluorescent oxygen sensor probe module based on planner lightwave circuits using UV imprint lithography. The oxygen sensor system is consisted of the optical source part, optical detector part and optical sensing probe part to be composed of the planner lightwave circuit and oxygen sensitive thin film layer. Firstly, we optimally designed the planner lightwave circuit with asymmetric $1{\times}2$ beam splitter using beam propagation method. Then, we fabricated the planner lightwave circuits using UV imprint lithography process. This planner lightwave circuits transmitted the optical power with 76% efficiency and the fluorescence signal with 70% efficiency. The oxygen sensitive thin film layer is coated on the end face of planner lightwave circuit. The oxygen sensor system using this sensor probe module with planner lightwave circuit could measure the concentration with 0.3% resolution from 0% to 20% gas range. This optical oxygen sensor probe module make it possible to compact, simple and cheap measurement system.

Analysis for Shielding Effectiveness of Metal Shielding Layer within Near-Field of Noise Source (노이즈 소스 근거리장에 위치한 금속 차폐막의 차폐효과 분석)

  • Lee, Won-Seon;Lee, Won-Hui;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.59-65
    • /
    • 2019
  • The EMI shielding effectiveness of the shielding layer thickness was analyzed when the metal shielding layer was placed in the near field of the magnetic probe and the noise source. Microstrip lines were used as noise source, and graphite and ferrite were selected as metal shielding materials. The magnetic probe uses the electromagnetic radiation measurement method using the magnetic probe by applying the IEC 61967-6 method. The transmission coefficient between the microstrip line and the magnetic probe was analyzed. The distance between the two was 1 mm for a single shielding layer and 5 mm for a multiple shielding layer. The thickness of the shielding layer was changed to 5 um, 10 um, 30 um, and 50 um. When the frequency was changed from 150 kHz to 1 GHz, a maximum shielding effectiveness (SE) of 44.9 dB was obtained.