• Title/Summary/Keyword: 측정효율

Search Result 8,155, Processing Time 0.043 seconds

HEMP Analysis and Shielding Effectiveness (HEMP 분석과 방호 효율성)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.20-24
    • /
    • 2013
  • In this paper, we introduce a concept of HEMP systems and analyze a shielding effectiveness by varying placements of the antenna elements. Maxwell's equations for the high frequency of the EMP is represented in the LOS. In order to investigate the effects of electromagnetic attenuations, a shielding room was constructed and employed to obtain measured data. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

Analyzing the Technical Efficiency of Korean Engineering and Construction Firms after the Financial Crisis (외환위기 이후 국내건설회사의 효율성 분석)

  • Kim, Kon-Shik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.1 s.23
    • /
    • pp.151-161
    • /
    • 2005
  • This paper analyzes the technical efficiencies of 38 Korean engineering and construction firms and the efficiency changes from 1999 to 2003 using data envelopment analysis (DEA). Best practice firms in terms of technical efficiency and profit are identified. For inefficient firms, performance targets to be efficient are suggested. Technical efficiencies had been increased over the five year period, and the efficiency difference between firms had been reduced during this period. The differences in efficiency due to the differences in cooperate governance structures are statistically significant. In addition, the technical efficiency is correlated with product portfolios, degree of subcontract, rates of value added, returns on invested capital, and EBITDA.

Instrumentation Performance Measurement Technique for Evaluating Efficiency of Binary Analysis Tools (바이너리 분석도구 효율성 평가를 위한 Instrumentation 성능 측정기법)

  • Lee, Minsu;Lee, Jehyun;Kim, Hobin;Ryu, Chanho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.6
    • /
    • pp.1331-1345
    • /
    • 2017
  • Binary instrumentation has been developed for monitoring and debugging executables without their source codes. Previous efforts on the binary instrumentation are mainly focused on its capability and accuracy, but not on efficiency for practical application. In particular, criteria and measurement methodologies for evaluating and comparing the efficiency of binary investigation tools and algorithms do not estimated yet. In this paper, we propose the instrumentation primitives which are a unit functionality and measurement methodology. Through the empirical experiments by adopting the proposed methodology on DynamoRIO and Pin, we show the feasibility of the proposal.

고속파 전자가열을 시도한 KSTAR 토카막 원형 플라즈마에서의 ICRF 고주파 부하 저항

  • Wang, Seon-Jeong;Kim, Seon-Ho;Gwak, Jong-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.297-297
    • /
    • 2010
  • KSTAR 토카막의 두번째 실험 캠페인 동안 고속파 전자가열 (FWEH)을 위한 ICRF 고주파입사 실험을 실시하였다. 토로이달 자기장은 2 T, 플라즈마 전류는 200-300 kA, 주반경은 1.8 m, 부반경은 0.5 m의 원형 플라즈마가 가열 대상이 되었으며, 네개의 ICRF 안테나 전류띠 가운데 중심부의 두개의 전류띠를 최대 300 kW로 구동하기 위한 운전 주파수는 44.2 MHz가 선택 되었다. 이 주파수는 플라즈마의 모든 영역에서 이온 사이클로트론 공명을 일으키지 않으므로 플라즈마에 흡수되는 대부분의 출력은 전자에게 전달될 것으로 기대되었다. 낮은 고주파-플라즈마 결합으로 인하여 전송선의 최대 고주파 전압이 허용치를 초과하기 때문에 비교적 낮은 최대 출력만이 허용 되었으나, ECE에 의해 관측된 전자의 온도는 국지적으로 최대 150 % 까지 증가하는 것을 확인 할 수 있었다. 낮은 고주파-플라즈마 결합의 첫번째 원인은 FWEH의 효율이 이온을 가열할 때 보다 상대적으로 낮기 때문이다. 플라즈마 내에 이온 사이클로트론 공명층이 형성되면 높은 효율로 고주파를 입사 할 수 있다는 것은 잘 알려진 사실이다. 또다른 원인은 D 형상의 플라즈마에 맞도록 만들어진 안테나와, 원형 플라즈마간의 부조화로 인하여 고속파 차단층이 (Fast Wave Cutt-off Layer) 평균적으로 넓게 형성되기 때문이다. 플라즈마 외곽에 반드시 존재하는 낮은 플라즈마 밀도의 고속파 차단층 내부에서, 중심부로 향하는 고주파의 진폭은 지수함수로 감쇠하므로 가능하면 플라즈마 밀도를 높여 차단층 자체의 폭을 줄이거나, 안테나 전류띠를 플라즈마에 바짝 접근시켜야만 한다. 고주파 진단 장치로는 송출기의 출력과 반사파 측정 장치, 공명루프의 전압 측정 장치가 있는데, 이것들을 이용하여 안테나에 전달되는 출력 및 고주파-플라즈마 결합 효율을 나타내는 플라즈마에 대한 고주파 부하 저항을 구할 수 있다. 측정 결과, 부하 저항의 최소값은 진공시 또는 ICRF만의 방전시의 값 0.25 Ohm 보다 큰 0.5 Ohm을 나타냈으며, 최대값은 플라즈마의 상태에 따라 1 Ohm에서 2 Ohm 사이에서 매우 빠르게 요동하는 것을 확인했다. Mm 파 반사계의 측정에 의하면 플라즈마 언저리의 위치가 약 3 cm 정도의 크기로 요동하는 것으로 나타났는데, 부하 저항과 언저리 위치의 파형이 정확하게 일치하지 않지만 유사한 경향성을 가진 것으로 보인다. 따라서 플라즈마 언저리 위치의 제어를 통하여 가열 효율을 높게 유지할 수 있음을 알 수 있다. 본 발표에서는 실험의 소개와 함께 부하 저항의 관점에서 가열 효율을 높일 방안을 토론하도록 한다.

  • PDF

형광체기반 Application에서 페를린 증착 유무에 따른 광학적 농도 변화에 대한 연구

  • Kim, Gyo-Tae;Hong, Ju-Yeon;Kim, Jin-Seon;Heo, Ye-Ji;Sin, Jeong-Uk;Heo, Seung-Uk;Park, Ji-Gun;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.397.1-397.1
    • /
    • 2014
  • 최근 방사선 진단 영역에 이용되고 있는 증감지는 입사된 방사선의 감도를 증가시키기 위해 형광체를 사용하고 있으며, 외부의 에너지를 흡수하여 빛으로 방출하는 역할을 한다. 이는 방사선 검출기, 디스플레이, 의료기기 등 다양한 분야에 활용되고 있다. 필름에 X선을 노출 할 경우 형광체의 사용 유무에 따라 방사선 흡수 효율에 영향을 미치며, 이는 발광 효율 및 감도에 주요한 인자로 작용한다. 현재 상용화되어 있는 형광체는 낮은 발광 효율로 인한 한계를 가지므로, 발광 효율 향상을 위하여 제작 구조에 대한 연구가 진행되고 있다. 이 중 반사막을 활용하는 연구가 활발히 진행되고 있다. 일반적으로 형광체의 제조를 위하여 보편적으로 이용하고 있는 스크린프린팅 방법에서 건조 공정을 수행 시 균일도가 감소하는 현상이 발생한다. 이러한 현상은 반사막의 증착을 불균일하게 만드는 원인으로 작용하고 빛의 산란을 초래하는 현상을 초래한다. 이에 본 연구에서는 증착 시 투명도 저하에 따라 반사율이 증가되는 반사막 성질을 가지며, 방수성 및 절연성과 같은 보호층 특성을 지닌 유기성 투명 박막 페를린에 대하여 연구하고자 한다. 본 연구에서는 화학적 증기 증착법(Chemical Vapor Deposition, CVD)을 이용하여 투명 필름의 상단에 페를린을 코팅한 시편과 코팅하지 않은 시편으로 구분하여 제작하였고, 상단에 스크핀프린팅 방법을 활용하여 형광체를 도포 하였다. 시편 제작 후 실험은 시편을 필름 상단에 위치시키고, 일반진단에너지 대역(Model-SF 80)의 X선을 조사하였다. 이 후 현상기(model-pro14)를 통해 현상된 필름에 나타난 광학적 농도(Optical Density, O.D)를 농도계(Fluke Biomedical Nuclear Associates Densitometer)로 측정하였는데, 불확실성을 줄이기 위하여 총 5회를 측정하여 그 중 2번째로 높은 값을 도출하였다. 측정 결과, 페를린을 코팅한 형광체에서는 1.71의 O.D 값이 측정되었고, 페를린을 코팅하지 않은 형광체에서는 1.43의 O.D 값이 측정되었다. 이를 이용하여 투명도를 산출한 결과 상대적으로 약 1.76% 차이가 나타났다. 이러한 결과는 페를린 활용 시 환자의 피폭 선량 저감화 및 해상력 개선을 도모할 수 있을 것으로 사료된다.

  • PDF

Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation (갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산)

  • Ahn, Ki-Soo;Cho1, Hyo-Sung
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • According to the Para. 5 of Art 2 of the Korean Nuclear Safety Regulations, which was revised in 1999, internal dose assessment as well as external one should be performed by law for employees at a nuclear power plant from 2003, and their estimate errors should also be within 50%. Thus, more accurate internal dosimetry becomes important. Corresponding to such regulation revision, we are developing a more accurate thyroid-uptake internal dosimetric system and have developed a Monte Carlo simulation code, the so-called CALEFF, to calculate the detection efficiency of the dosimetric system. In this paper, we calculated detection efficiencies with various test conditions by using the CALEFF code and discussed their characteristics. We may use the detection efficiency calculated by the code in calibrating the thyroid internal dose from measured data.

  • PDF

Method to Obtain the Antenna Efficiency of a Base Station in the Middle Frequency Band (중파 대역 기준국 안테나의 효율 측정 방법)

  • Bae, Su-Won;Kwon, Se-Woong;Lee, Woo-Sung;Moon, Hyun-Wook;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.572-579
    • /
    • 2008
  • To predict the system coverage in the middle frequency(MF) band, it is required to know the antenna efficiency at a base station. However, calculating the accurate efficiency is difficult since the efficiency may change according to the area where the antenna is installed. Thus, this paper proposes a method to obtain the antenna efficiency of a base station in the MF band from the measurement. This method uses the measured field strengths and the attenuation model in the MF band. Therefore, an attenuation model which is used in the proposed method is presented at first. Then, the process of the proposed method is followed using detailed explanations. Finally, antenna efficiencies of base stations which are currently operating are obtained by applying the proposed method and the usefulness of the obtained results are verified by comparing with ideal efficiencies.

DEA모형을 이용한 공공기관 효율성분석에 관한 사례연구: 일선우체국을 중심으로

  • Kim, Tae-Ung
    • The Korean Journal of Financial Studies
    • /
    • v.6 no.1
    • /
    • pp.47-65
    • /
    • 2000
  • 효율성은 산출물의 가치와 그 산출물을 창출해 내기 위해 생산과정에서 소비한 투입물 가치의 비율로 나타낸다 투입물이나 산출물의 시장가격이 존재하는 경우 이 값을 가중치로 이용하여 산출물과 투입물의 가치를 계산할 수 있다. 그러나 투입물과 산출물의 종류가 다양한 경우에는 투입물의 가치를 적절히 평가하기가 쉽지 않다. Data Envelopment Analysis(DEA)모형은 효율성을 여러 가지 투입물의 가중평균에 대한 여러 가지 산출요소의 가중평균의 비율로 표시하며, 특정 의사결정단위의 효율성 정도는 유사한 투입 산출구조를 가지는 준거집단과 비교하여 상대적으로 측정하고자 하는 방법이다. 본 논문에서는 DEA모형의 구조와 이론적 근거, 그리고 적용상의 장단점에 대해 알아 본 뒤 국내 일선우체국의 운영자료를 토대로 하여 공공적인 성격을 띠는 기관의 운영효율성 측정에의 적용사례를 제시하였다. 투입자료로는 '98년 우정사업자료를 중심으로 공통영업비, 우편영업비, 금융영업비, 직원수, 관할가구수, 관할면적, 고정자산 등 7개 변수와 우편영업수익, 금융영업수익, 보험수지차, 배달 및 중계 우편물량, 현금출납 취급건수, 연평잔실적의 6개 변수를 각각 투입물과 산출물 변수로 설정하여 모형을 구축하였다. 분석대상으로 삼은 64개 우체국 전체의 효율성 평균은 82.14%으로 나타났으며 DEA모형의 효율성결과와 기존에 이미 발표된 정보통신부 평가결과와의 상관관계는 0.46291로 강하지는 않지만 두 변수간에는 정(正)의 상관관계가 있음을 알 수 있었다.

  • PDF

Efficiency Measurement Method and Simplification of Program (프로그램의 효율성 측정 방법과 간소화)

  • Yang, Hae-Sool
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.1
    • /
    • pp.49-62
    • /
    • 1998
  • Softwares which have many functions to satisfy user's requirements is developing. But generally, users use partial functions of software. If we could construct software which leave useful functions and remove unuseful functions in software with many functions, we could enhance execution efficiency by reduction of program size and quality of software. There are 6 items in international standard ISO/IEC 9126 about quality of software. These are functionality, reliability, usability, efficiency, maintenance and portability. In this study, we proposed metrics for measurement of efficiency and simplification method for source code. And we described products evaluation result and indicated problem and progress method for practical development project about proposed efficiency metrics.

  • PDF

초음파 처리 시간 변화에 따른 나노 구조 P3HT층을 가진태양전지의 특성

  • Lee, Yong-Hun;Kim, Dae-Hun;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.398.2-398.2
    • /
    • 2014
  • 유기태양전지는 낮은 공정 단가, 저온공정 및 기계적 유연성과 같은 다양한 장점을 지니고 있어서 실리콘 기반의 태양전지를 대체하기 위해서 많은 연구가 진행되고 있다. 유기태양전지는 실리콘 기반의 태양전지에 비해서 낮은 광전변환효율을가지고 있기 때문에 효율을 높이기 위한 다양한 연구가 진행되고 있다. 그 중에서 엑시톤 분리 효율을 높이기 위한 방안으로 나노 구조가 많이 연구되고 있다. 하지만 나노 구조를 제작하기 위해서는 식각 과정을 거치거나, 금속 템플레이트를 사용하여 공정상 복잡하고 어려움을 갖는다. 본 연구에서는 간단한 용액 공정을 이용하여 초음파 처리시간 변화에 따른 나노 구조를 가지는 광활성층을 제작하였다. 전자주게 물질인 P3HT를 혼합 용매에 녹여서 초음파 처리를 통해서 나노 구조를 제작하였고, 초음파 처리 시간에 따른 구조의 변화를 광류미네에센스 측정과 원자간 힘 현미경으로 관찰하였다. 나노 구조를 가지는 태양 전지는 엑시톤을 분리할 수 있는 전자주게와 전자받게의 계면이 증가함으로 엑시톤 분리 효율이 향상되는 장점을 가진다. 초음파 처리 사긴 변화에 따른 나노 구조 P3HT 층을 가진 태양전지의 전류밀도-전압 측정을 통해 효율의 변화를 비교하였다. 15분 동안 초음파 처리를 하였을 때, 가장 높은 효율을 가지는 것을 확인할 수 있었고, 나노 구조를 가지지 않는 유기태양전지에 비해서 20% 정도 효율이 향상되는 결과를 볼 수 있었다.

  • PDF