• Title/Summary/Keyword: 측정표준기술

Search Result 929, Processing Time 0.03 seconds

A Study on the Compatibility of Korean Temperature Guidelines for Stockpile Material Environmental Test (저장물자 환경시험을 위한 한국적 온도기준 적합성 연구)

  • Lee, Il Ro;Byun, Kisik;Cho, Sung-Yong;Kim, Kyung Pil;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.187-194
    • /
    • 2020
  • The T&E (Test and Evaluation) results were applied for a judgment basis to decide the developmental process of system engineering for efficient weapon system R&D (Research and Development). During the OT&E (Operational Test and Evaluation) and DT&E (Development Test and Evaluation), an environmental test is essential for weapon system development owing to their highly exposed operational conditions. Based on the MIL-STD-810, MIL-HDBK-310, and AECTP 200, the ROK armed forces recommended operating temperatures for the ROK weapon system and applied this to the DT&E and OT&E. This study examined the compatibility of Korean temperature guidelines for stockpile material considering recent climate change. Moreover, this study analyzed the data from hourly measured temperatures on 101 observatories during 60 years, from 1960 to 2020, and percentage (0.5%, 1%, 5%, and 10%) and the 𝜎 (3𝜎, 2𝜎, and 1𝜎) frequency of occurrence on rigorous hot (August) and cold (January) periods, respectively. The results indicate that the highest temperature was 41℃, and the 0.5% frequency of occurrence was 37.0℃. In the case of the cold period, the lowest temperature was -32.6℃ and the 0.5% frequency of occurrence was -21.1℃. By considering the previously recommended operating temperature range for a general ground system, -30 ~ 40℃, regional operation probability is recognized 99.999%. Despite the recent abnormal climate change from global warming, the Korean temperature guidelines are compatible with the stockpile material environmental test.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Study on the Characteristics of EEG in Resting State on Visuo-Spatial Working Memory Performance (시공간 작업기억 수행능력에 따른 안정상태에서의 뇌파 특성 연구)

  • Jung, Chul-Woo;Lee, Hyeob-Eui;Wi, Hyun-Wook;Choi, Nam-Sook;Park, Pyong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.351-360
    • /
    • 2016
  • The purpose of this study is to predict visual-spatial working memory performance through the characteristics of an electroencephalogram (EEG) in the resting state. The 31 study participants, middle school students with various to academic performance, were underwent visual-spatial working memory test in the Comprehensive Attention Test (CAT) on December in 2014. Each 7 and 6 participants were divided into an Excellent Working Memory (EWM) group and Poor Working Memory (PWM) group depending on the forward/backward working memory scores. The EEG measurements and analysis of the data from a Brain Function Tester were performed by the two groups. A Mann-Whitney Test was used to examine the statistical differences between them. The activation of high beta (${\beta}H$) at the Fp1 and Fp2 sites in the left and right hemisphere, and that of the low beta (${\beta}L$) in the right hemisphere in the EWM group was significantly higher than that in the PWM group. In conclusion, there is a correlation between the visual-spatial working memory performance and the activation of ${\beta}H$ and ${\beta}L$ in the resting state and a close correlation that of ${\beta}L$ in the right hemisphere in terms of mental activity and faculty. Therefore, the visual-spatial working memory performance can be predicted by the activation of ${\beta}H$ and ${\beta}L$ in the resting state. The activation of EEG can be applied as an assessment tool and provide basis data for visual-spatial working memory performance.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Relationships of Obesity, Total-Cholesterol, Hypertension and Hyperglycemia in Health Examinees with Disabilities (장애인 건강검진 수검자들의 비만, 콜레스테롤, 고혈압, 고혈당의 관련성)

  • Hong, Min-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.591-599
    • /
    • 2016
  • Among the employer-supported subscribers to the National Health Insurance Service, 6,797 people with mild disabilities with western ages of 20 and up and who received health checkups were investigated. Of these 6,797 people, 3,186 and 3,611 received health checkups in 2009 and 2013, respectively. Those people who were diagnosed with physical handicaps, brain lesions, visual impairment, hearing impairment, intellectual disabilities, mental disorders, kidney disorders or other disorders according to the classification standard for people with disabilities were classified into disability groups of the 3rd through 6th degrees. The purpose of this study was to examine the dangerous influence of obesity of people with mild disabilities on their hyperglycemia, hypertension and high cholesterol. The items measured in this study were abdominal obesity, body mass index, fasting glucose, total cholesterol, systolic blood pressure and diastolic blood pressure. To look for connections between the obesity level and at-risk groups for each disease, cross tabulation and multinomial logistic regression analyses were utilized. Higher levels of abdominal obesity and BMI were found among those who were male, were younger and had higher incomes. The risks of abdominal obesity and BMI were higher in the abnormal groups for each disease. In 2009, the obesity group whose BMI was higher had a 1.51-fold higher risk of hypertension than the normal group. The abdominal obesity group had a 1.59-fold higher risk of high cholesterol, a 1.26-fold higher risk of hypertension and a 1.54-fold higher risk of hyperglycemia than the normal group. In 2013, the obesity group whose BMI was higher had a 1.72-fold higher risk of high cholesterol and a 1.43-fold higher risk of hypertension than the normal group. Those with abdominal obesity had a 1.59-fold higher risk of hyperglycemia than the normal subjects. As the risk of obesity was higher in those with disabilities than in those without disabilities, the former should be encouraged to undergo health checkups on a regular basis, and the coverage of the health checkups should be extended to keep track of their illness. In addition, appropriate education and concern are both required to prevent obesity.

Performance Optimization of Numerical Ocean Modeling on Cloud Systems (클라우드 시스템에서 해양수치모델 성능 최적화)

  • JUNG, KWANGWOOG;CHO, YANG-KI;TAK, YONG-JIN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.27 no.3
    • /
    • pp.127-143
    • /
    • 2022
  • Recently, many attempts to run numerical ocean models in cloud computing environments have been tried actively. A cloud computing environment can be an effective means to implement numerical ocean models requiring a large-scale resource or quickly preparing modeling environment for global or large-scale grids. Many commercial and private cloud computing systems provide technologies such as virtualization, high-performance CPUs and instances, ether-net based high-performance-networking, and remote direct memory access for High Performance Computing (HPC). These new features facilitate ocean modeling experimentation on commercial cloud computing systems. Many scientists and engineers expect cloud computing to become mainstream in the near future. Analysis of the performance and features of commercial cloud services for numerical modeling is essential in order to select appropriate systems as this can help to minimize execution time and the amount of resources utilized. The effect of cache memory is large in the processing structure of the ocean numerical model, which processes input/output of data in a multidimensional array structure, and the speed of the network is important due to the communication characteristics through which a large amount of data moves. In this study, the performance of the Regional Ocean Modeling System (ROMS), the High Performance Linpack (HPL) benchmarking software package, and STREAM, the memory benchmark were evaluated and compared on commercial cloud systems to provide information for the transition of other ocean models into cloud computing. Through analysis of actual performance data and configuration settings obtained from virtualization-based commercial clouds, we evaluated the efficiency of the computer resources for the various model grid sizes in the virtualization-based cloud systems. We found that cache hierarchy and capacity are crucial in the performance of ROMS using huge memory. The memory latency time is also important in the performance. Increasing the number of cores to reduce the running time for numerical modeling is more effective with large grid sizes than with small grid sizes. Our analysis results will be helpful as a reference for constructing the best computing system in the cloud to minimize time and cost for numerical ocean modeling.

Feasibility Assessment on the Application of X-ray Computed Tomography on the Characterization of Bentonite under Hydration (벤토나이트 수화반응 특성화를 위한 X선 단층촬영 기술 적용성 평가)

  • Melvin B., Diaz;Gyung Won, Lee;Seohyeon, Yun;Kwang Yeom, Kim;Chang-soo, Lee;Minseop, Kim;Jin-Seop, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.491-501
    • /
    • 2022
  • Bentonite has been proposed as a buffer and backfill material for high-level radioactive waste repository. Under such repository environment conditions, bentonite is subjected to combined thermal, hydrological, mechanical, and chemical processes. This study evaluates the feasibility of applying X-ray CT technology on the characterization of bentonite under hydration conditions using a newly developed testing cell. The cylindrical cell is made of platic material, with a removable cap to place the sample, enabling to apply vertical pressure on the sample and to measure swelling pressure. The hydration test was carried out with a sample made of Gyeonju bentonite, with a dry density of 1.4 g/cm3, and a water content of 20%. The sample had a diameter of 27.5 mm and a height of 34 mm. During the test, water was injected at a constant pressure of 0.207 MPa, and lasted for 7 days. After one day of hydration, bentonite swelled and filled out the space inside the cell. Moreover, CT histograms showed how the hydration process induced an initial increase and later progressive decrease on the density of the sample. Detailed profiles of the mean CT value, CT standard deviation, and CT gradient provided more details on the hydration process of the sample and showed how the bottom and top regions exhibited a decrease on density while the middle region showed an increase, especially during the first two days of hydration. Later, the differences in CT values with respect to the initial state decreased, and were small at the end of testing. The formation and later reduction of cracks was also characterized through CT scanning.

Clinical Characteristics of precocious puberty girls and Comparison Analysis of GnRH Test results with Diagnosis type (성조숙증 여아들의 임상적 특징 및 진단별 성선자극호르몬 분비호르몬 GnRH (Gonado Tropin Releasing Hormone) 검사결과의 비교분석평가)

  • Kim, Jung-In;Kwon, Won-Hyun;Moon, Ki-Choon;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.54-61
    • /
    • 2016
  • Purpose Precocious Puberty is defined as the development of secondary sexual characteristics in girls younger than 8 years, and boys 9 years. Cause premature closure of the epiphysis is a disease that eventually decreases the final adult height. In this study, we retrospectively analyzed to evaluate the diagnostic difference the GnRH (Gonado-tropin-releasing Hormone) stimulation test results with medical records of precocious puberty in girls. Materials and Methods From February 2015 to December 2015 it was enrolled in the girls 118 people who visited the Seoul National University Bundang Hospital, Pediatrics, Endocrinology Internal Medicine. True precocious puberty group (n=57), early puberty group (n=39), were divided into Premature thelarche (n=22) group. A Tanner stage, chronological age, bone age, height, body weight for each group was determined by examining the mean${\pm}$standard deviation. GnRH test result was compared LH (Basal, 30 min, 45 min, 60 min), FSH (Basal, 30 min, 60 min) for each group, Each group LH, FSH Peak value distribution, the mean${\pm}$standard deviation was calculated for the peak LH/LH basal ratio, peak LH/Peak FSH ratio. The significance probability (P-value) between the value of each third group was determined. Results The average height of the true precocious puberty group $131{\pm}14.85$, the mean weight was $28.80{\pm}4.93$, the average chronological age $7.1{\pm}0.81$, the mean bone age was $9.9{\pm}0.9$, The average height of early puberty group was $134{\pm}5.10$, the average weight $28.50{\pm}4.43$, the average chronological age $8.05{\pm}0.03$, the mean bone age was $10.0{\pm}0.62$, The average height of Premature thelarche $129{\pm}6,01$, the average weight was $28.65{\pm}5.98$, the average chronological age $7.02{\pm}0.58$, the mean bone age was $8.04{\pm}1.29$. There was no significant difference when compared to the height and weight. There was a significant difference between the groups in the chronologic age and bone age difference (P <0.0002) True precocious puberty group showed peak LH levels at 30'(82.5%), 45'(12.3%), 60'(5.3%), in Peak FSH 30'(8.8%), 60'(91.2%). Early Puberty group showed high values in Peak LH at 30'(79.5%), 45'(17.9%), 60'(2.6%), in peak FSH levels at 30'(7.7%), 60'(92.32%). In Premature thelarche Group it showed the Peak LH levels at 30'(30%), 45'(59%), 60'(9.09%), Peak FSH levels at 30'(0%) 60'(100%). When compared with the The Peak LH/basal LH ratio, True precocious puberty group was $19.09{\pm}17.15$, early puberty group was $15.23{\pm}10.88$, Premature thelarche group showed significant differences between the three groups as $4.93{\pm}4.36$.(P <0.0001) LH Peak/FSH Peak ratio, true precocious puberty group was $1.222{\pm}0.77$, early puberty group was $1.34{\pm}1.23$, Premature thelarche group showed significant differences between the three groups as $0.3{\pm}0.09$(P <0.0001) Conclusion In order to diagnose the true precocious puberty have a diagnostic value when the LH peak after GnRH stimulation is increased by more than two to three times compared to baseline or a predetermined level or more than 5~10 IU/L increases. GnRH Test is a test for a long time and the patient discomfort due to repeated blood sampling, but the hypothalamus-pituitary gland- gonad axis activity evaluate and is the most basic accurate test in the differential diagnosis of precocious puberty disorders.

  • PDF

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF