• Title/Summary/Keyword: 측정표준기술

Search Result 929, Processing Time 0.034 seconds

Experimental Study on Loading Capacity of SY Corrugated Steel Form for RC Beam and Girder (SY 비탈형 보거푸집의 내하성능에 관한 실험적 연구)

  • Bae, Kyu-Woong;Boo, Yoon-Seob;Hwhang, Yoon-Koog;Shin, Sang-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.32-39
    • /
    • 2021
  • Recently, necessities of steel form for reinforced concrete beam and girder have been emphasized in building structures for the reduction of the construction period and the labor cost. SY Beam was developed for the these purposes and is roll-formed using thin steel plate. On this research, we tried to evaluate and verify the performance and behavior of SY Beam under construction loading stage as like pouring in situ concrete. For the standard shape of SY beam, structural modelling with various steel thicknesses has carried out using MIDAS GEN program. From results of modelling, the width and height of SY Beam were determined 600mm and 400mm respectively. For 3 SY Beams, the loading experiment was performed to measure vertical and horizontal displacement under stacking sand, concrete block, and bundle of rebar. As a result, the vertical deflection showed a tendency to decrease as the thickness increased. In the horizontal displacement, the trend according to the thickness was not clearly observed. From the evaluation on the loading experiment, it is considered that the SY Beam can secure both workability and structural safety. In particular, the SY Beam(1.2mm) hardly generates horizontal displacement, so it has excellent load-bearing capacity. So, we judged that the SY Beam with 1.2mm steel plate has excellent performance and consider to be immediately commercially available.

An Empirical Study on Effective Relation among Trust, Camaraderie, and Pride Perceived by Employees of an R&D Institute : on the Basis of GPTW Trust Index (연구개발조직 구성원이 인식하는 신뢰, 동료애, 자부심의 영향관계에 대한 실증연구 : GPTW 신뢰지수를 중심으로)

  • Pae, Jaesung;Seo, Young Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.565-572
    • /
    • 2019
  • As a public research institute, government-supported institutes have led the industrial development and the advancement of science and technology in Korea. Robert Levering has annually selected 'Fortune 100 GPTW(Great Place to Work)' by measuring the Trust Index which was originated by himself. The objectives of this study are to attempt newly to analyze the inter-relations among 5 elements of GPTW trust index such as credibility, respect, fairness, camaraderie, and pride perceived by the K institute's 262 employees; to verify that GPTW trust index is valid for the selection of the fortune 100 GPTW. Amart PLS 2.0 and SPSS 18 were utilized for the statistical analysis. The results of this study are as follows. Credibility has positive effect to pride; respect has positive effect to pride and camaraderie; fairness has positive effect to camaraderie; and camaraderie has positive to pride. Pride and camaraderie have positive effect to the perceived GPTW. Recent studies mainly focused on the relations between GPTW trust index as independent, mediating variables or parameters and organizational performances. It is meaningful that this study has firstly tried to analyze the inter-relations among 5 elements of the trust index for the employees of research institute. This study has implication that the in order to enhance the performance the institute has to manage GPTW trust index perceived by the employees.

Applying ISO/IEC 25023 to Software Engineering Process in Weapon System for Quality Improvement (무기체계 소프트웨어 품질 개선을 위한 ISO/IEC 25023의 소프트웨어 개발 프로세스 적용 방안)

  • Yoon, Gyeonghwan;Yu, Jiseon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.387-393
    • /
    • 2021
  • This study aimed to improve the software quality in weapon systems by applying ISO/IEC 25023 to the software engineering process. The software engineering process in weapon systems manages the Software Quality Requirement but has restrictively improved the software quality. Software quality items are already defined and used for software engineering processes in weapon systems, but they are defined inconsistently according to individual software development cases. Thus, the methods of quantifying software quality are different, even though the same software quality is defined. In addition, the software quality has been managed differently. The major problems of software engineering processes in weapon systems are the unclear definition of the software quality requirements and the absence of quantifying software quality standards. ISO/IEC 25023 is composed of eight quality characteristics and thirty-one sub-characteristics. ISO/IEC 25023 provides measurement functions that can quantify the software product quality based on its characteristics. To improve the software quality further, the measurement functions in ISO/IEC 25023 are suggested to quantify and manage software quality for software engineering processes in weapon systems. The expected effects of this study were analyzed.

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

Study of system using load cell for real time weight sensing of artificial incubator (인공부화기의 실시간 중량감지를 위한 로드셀을 이용한 시스템 연구)

  • jeong, Jin-hyoung;Kim, Ae-kyung;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.2
    • /
    • pp.144-149
    • /
    • 2018
  • The eggs are incubated for 18 days through the generator and incubated in the developing incubator. During the developmental period, the weight loss of the fetus is correlated with the ventricular formation, and the proper ventricular formation is also associated with the healthy embryonic hatching and the egg hatching rate. However, in the incubator period of the domestic hatchery, it is a reality to acquire the resultant side by the Iranian standard weight measurement with the experience of the hatchery and the person concerned and the development period without the apparatus for measuring the present weight. As a result, prevalence of early mortality, hunger and illness during hatching are frequent. Monitoring the reduction of weaning weight is crucial to obtaining chick quality and hatching performance with weight changes within the development machine. Water loss is different depending on the size of eggs, egg shell, and elder group. We can expect to increase the hatching rate by measuring the weight change in real time and optimizing the ventilation change accordingly. There is a need to develop a real-time measurement system that can control 10 to 13% reduction of the total weight during hatching. The system through this study is a way to check the one - time directly when moving the existing egg, and it is impossible to control the measurement of the fetal water evaporation within the development period. Unlike systems that do not affect the hatching rate, four load cells are connected in parallel on the Arduino sketch board and the AT-command command is used to connect the mobile phone and computer in real time. The communication speed of Bluetooth was set to 15200 to match the communication speed of Arduino and Hyper-terminal program. The real - time monitoring system was designed to visually check the change of the weight of the fetus in the artificial incubator. In this way, we aimed to improve the hatching rate and health condition of the hatching eggs.

Audio Stream Delivery Using AMR(Adaptive Multi-Rate) Coder with Forward Error Correction in the Internet (인터넷 환경에서 FEC 기능이 추가된 AMR음성 부호화기를 이용한 오디오 스트림 전송)

  • 김은중;이인성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12A
    • /
    • pp.2027-2035
    • /
    • 2001
  • In this paper, we present an audio stream delivery using the AMR (Adaptive Multi-Rate) coder that was adopted by ETSI and 3GPP as a standard vocoder for next generation IMT-2000 service in which includes combined sender (FEC) and receiver reconstruction technique in the Internet. By use of the media-specific FEC scheme, the possibility to recover lost packets can be much increased due to the addition of repair data to a main data stream, by which the contents of lost packets can be recovered. The AMR codec is based on the code-excited linear predictive (CELP) coding model. So we use a frame erasure concealment for CELP-based coders. The proposed scheme is evaluated with ITU-T G.729 (CS-ACELP) coder and AMR - 12.2 kbit/s through the SNR (Signal to Noise Ratio) and the MOS (Mean Opinion Score) test. The proposed scheme provides 1.1 higher in Mean Opinion Score value and 5.61 dB higher than AMR - 12.2 kbit/s in terms of SNR in 10% packet loss, and maintains the communicab1e quality speech at frame erasure rates lop to 20%.

  • PDF

Efficient Multicasting Mechanism for Mobile Computing Environment (웹 페이지 로딩시간 감축을 위한 HTML 5 분석)

  • Yun, Jun-soo;Park, Jin-tae;Hwang, Hyun-seo;Phyo, Gyung-soo;Moon, Il-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.775-778
    • /
    • 2015
  • HTML5-based Web platform is established as a next-generation national standards, Web services provider, has been competitively develop support technology HTML5-based app in smart media devices and smart TV. In accordance with the W3C is an international Web standards development organization, Microsoft, Apple, Mozilla, Google, such as Opera, various Web browser vendors are participating in standardization. Gradually emphasized the importance of HTML5, HTML5 -based Web pages, it is necessary to fast load times when contained a large amount of information. Therefore, in this paper, the initial studies in order to reduce the loading time of a web page, configure each browser-specific same Web page, and measure the initial loading time. Also, one by one remove the HTML5 tags, and CSS property, to analyze the tags and attributes of the account for a large proportion to the initial load time. Through the results, it is desired to provide a process which can reduce the Web page.

  • PDF

Determination of the Optimal Height using the Simplex Algorithm in Network-RTK Surveying (Network-RTK측량에서 심플렉스해법을 이용한 최적표고 결정)

  • Lee, Suk Bae;Auh, Su Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • GNSS/Geoid positioning technology allows orthometric height determination using both the geoidal height calculated from geoid model and the ellipsoidal height achieved by GNSS survey. In this study, Network-RTK surveying was performed through the Benchmarks in the study area to analyze the possibility of height positioning of the Network-RTK. And the orthometric heights were calculated by applying the Korean national geoid model KNGeoid13 according to the condition of with site calibration and without site calibration and the results were compared. Simplex algorithm was adopted for liner programming in this study and the heights of all Benchmarks were calculated in both case of applying site calibration and does not applying site calibration. The results were compared to Benchmark official height of the National Geographic Information Institute. The results showed that the average value of the height difference was 0.060m, and the standard deviation was 0.072m in Network-RTK without site calibration and the average value of the height difference was 0.040m, and the standard deviation was 0.047m in Network-RTK with the application of the site calibration. With linearization method to obtain the optimal solution for observations it showed that the height determination within 0.033m was available in GNSS Network-RTK positioning.

Basic Lunar Topography and Geology for Space Scientists (우주과학자에게 필요한 달의 지형과 지질)

  • Kim, Yong Ha;Choi, Sung Hi;Yu, Yongjae;Kim, Kyeong Ja
    • Journal of Space Technology and Applications
    • /
    • v.1 no.2
    • /
    • pp.217-240
    • /
    • 2021
  • Upon the human exploration era of the Moon, this paper introduces lunar topography and geologic fundamentals to space scientists. The origin of scientific terminology for the lunar topography was briefly summarized, and the extension of the current Korean terminology is suggested. Specifically, we suggest the most representative lunar topography that are useful to laymen as 1 ocean (Oceanus Procellarum), 10 maria (Mare Imbrium, Mare Serenitatis, Mare Tranuillitatis, Mare Nectaris, Mare Fecundatis, Mare Crisium, Mare Vaporium, Mare Cognitum, Mare Humorum, Mare Nubium), 6 great craters (Tyco, Copernicus, Kepler, Aristachus, Stebinus, Langrenus). We also suggest Korean terms for highland, maria, mountains, crater, rille, rima, graben, dome, lava tube, wrinkle ridge, trench, rupes, and regolith. In addition, we introduce the standard model for the lunar interior and typical rocks. According to the standard model on the basis of historical impact events, the lunar geological eras are classified as Pre-Nectarian, Nectarian, Imbrian, Erathostenesian, and Copernican in chronologic order. Finally, we summarize the latest discovery records on the water on the Moon, and introduce the concept of water extraction from the lunar soil, which is to be developed by the Korea Institute of Geoscience and Mineral Resources (KIGAM).

Design and Implementation of a Mobile Ubiquitous Healthcare System (모바일 유비쿼터스 헬스케어시스템 설계 및 구현)

  • Lee, Bong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.781-793
    • /
    • 2010
  • Recently, owing to the development of ubiquitous sensor network and mobile communication technologies, many studies on healthcare system are being carried out. In this paper, we have designed and implemented a mobile u-Healthcare system based on sensor network. The u-Healthcare system is composed of three components: wireless sensor network at home, healthcare center located at remote site, and gateway which relays sensing physiological signals to healthcare center. In order to measure patient's physiological signal three sensors are used: three channel ECG sensor, pulse oximeter, and blood pressure sensor. Each sensor is mounted on a mote which can send gathered signal to the base node using Zigbee communication protocol. Once the base node receives physiological signal from each sensor, the client in the base node transfers the signal to the healthcare center. The received physiological signal at the healthcare center is analyzed and processed using various algorithms. The processed results are compared to the standard healthcare database and appropriate treatment including dietetics and exercise cure would be sent to the patient as feedback using SMS message or healthcare center web site. Each patient can check and manage one's health state every day using the healthcare system and gain a recovery under the treatments from minor health problems.