• Title/Summary/Keyword: 측정전류원

Search Result 254, Processing Time 0.028 seconds

Effect of misconvergence on resolution of color CRT monitor (칼라 CRT 모니터의 misconvergence에 따른 분해능 평가)

  • 김태희;이윤우;조현모;이인원;최옥식;정봉교
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.138-145
    • /
    • 1999
  • By varying the beam current of a color CRT(cathode ray tube) monitor, the misconvergence, spot size, display luminance, and chromaticity coordinate of a white pattern were measured at 4 screen positions. The misconvergence was measured with a linear CCD (charge coupled-device). The resolution was obtained by using SQRI (square root integral) method. The misconvergence of a color monitor was not influenced by the beam current but by the screen position. The misconvergence on a screen perimeter caused the resolution to decrease.

  • PDF

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.

Transient Response characteristics Associated with the Common Connection Points in Grounding Systems for Electric Power Utilitires (전력설비용 접지시스템에 공결점에 따른 과도응답특성)

  • 이복희;이승칠;엄주홍;심판섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.101-108
    • /
    • 1999
  • Ths paper describes the transient response characteristics of the grounding systems for electric power facilities against impluse currents. In this work, when the impulse current was injected through the grounding conductor for arrester, the investigations treasuring and analyzing potential rises induced at the cormron cormection trint and other grounding conductors were conducted. The lightning impulse current was awliErl so as to simulate the on-set of arrester due to lightning surges. Measured results of impulse response characteristics from the present experinrrits are as follows;

  • PDF

Measurement and Analysis of Surges on Information Devices Installed in a Power Substation (변전소내 정보기기에서 서지의 측정과 분석)

  • Song Jae-yong;Park Dae-won;Seo Hwang-dong;Han Joo-sup;Kil Gyung-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.289-294
    • /
    • 2005
  • This paper deals with the analysis results of surge voltage and current measured on information devices installed in a power substation. The power recorder to measure surge voltage and current was connected to signal lines near power transformers and switches, and the time resolution of the power recorder is 4 MS/s. Peak value of the measured surge voltage and current were ranges of 500~1,300v and 500~3,100k, respectively. During the period of measurement, over 5~10 events per day were recorded. Consequently, information devices installed in around high voltage power facilities should be designed considering the surge voltage and current caused in the condition.

AC Loss of a Cylindrical Multilayer conductor for various layer current distribution (상이한 층간전류분포에서 원통형 다층 도체의 교류손실)

  • Li, Z.;Ryu, K.;Oh, S.R.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.529-530
    • /
    • 2011
  • 10본의 선재로 각각 구성되는 내층과 외층을 지니는 2층 원��형 도체를 제작하여 그에 대한 교류손실을 측정하기 위하여, 각 층에 전압리드(inner-lead, outer-lead)들을 부착하였으며, 이로부터 픽업된 층 전압과 층 전류로부터 각 층의 손실을 평가하였다. 그 결과를 요약하면, 외층 전류가 내층의 1/2임에도 불구하고 내 외층의 손실은 거의 일치하였다. 또한 내 외층의 전류가 일치한 경우에도 외층 손실은 내층보다 대단히 크다. 이들 결과는 외층은 내층 전류로부터 발생되는 외부 자장하에 있어 외층의 자장이 증가된 것으로 사료된다.

  • PDF

Sputtering yield of the MgO thin film grown on the Cu substrate by using the focused ion beam (집속이온빔을 이용한 구리 기판위에 성장한 MgO 박막의 스퍼터링 수율)

  • 현정우;오현주;추동철;최은하;김태환;조광섭;강승언
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.396-402
    • /
    • 2001
  • MgO thin films with 1000 $\AA$ thickness were deposited on Cu substrates by using an electron gun evaporator at room temperature. A 1000 $\AA$ thick Al layer was deposited on the MgO for removing the charging effect of the MgO thin film during the measurements of the sputtering yields. A Ga ion liquid metal was used as the focused ion beam(FIB) source. The ion beam was focused by using double einzel lenses, and a deflector was employed to scan the ion beams into the MgO layer. Both currents of the secondary particle and the probe ion beam were measured, and they dramatically changed with varying the applied acceleration voltage of the source. The sputtering yield of the MgO layer was determined using the values of the analyzed probe current, the secondary particle current, and the net current. When the acceleration voltage of the FIB system was 15 kV, the sputtering yield of the MgO thin film was 0.30. The sputtering yield of the MgO thin film linearly increases with the acceleration voltage. These results indicate that the FIB system is promising for the measurements of the sputtering yield of the MgO thin film.

  • PDF

고조파에 의한 증성선 과전류 개선사례

  • Gang, Chang-Won;Lee, Jin-Seok
    • Electric Engineers Magazine
    • /
    • v.215 no.7
    • /
    • pp.17-21
    • /
    • 2000
  • Hook-On Meter로 중선선전류를 측정하면 큰 전류가 흘러 현장의 담당자를 어리둥절하게 만든다. 대부분의 기술자는 이 경우 누전에 의한 것이 아닌가 하는 의구심을 갖게 되나 실은 영상분 고조파에 의한 것임을 밝혀둔다. 최근 OA기기를 많이 쓰는 빌딩은 전부 이 문제를 가지고 있다. 이 영상분 고조파는 변압기, 케이블, MCCB 과열의 원인이 되고 대지전위상승 등 Noise 원으로 작용해 큰 피해가 우려된다

  • PDF

DC 블로워 모터의 이상소음 및 진동 진단 시스템 개발

  • 김정욱;김성렬;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.280-280
    • /
    • 2004
  • 기계의 소음 및 진동은 환경요인과 함께 기계의 정밀도 향상 및 고장진단과 관련하여 가장 중요한 분야중 하나이다. 특히 기계의 구동원으로 가장 많이 사용되고 모터는 기계설비이면서도 전기적인 현상으로 작동하기 때문에 설비보전의 사각지대로 나타나고 있다. 또한, 진동으로 모터의 전기적인 결함을 분석하기에는 미흡한 부분이 나타나기 때문에 모터 전용분석 기법을 사용하여 전동기의 전기적 결함을 분석하면 보다 정확한 진단이 가능하다. 현재 일부 생산 현장에서는 모터를 진단하기 위해 진동, 온도, 전류 등의 측정기법 들을 이용하여 분석하고 있다.(중략)

  • PDF

Analysis of Current Perception Threshold(CPT) Change after Dental Surgery using Neurometer (치과 수술 후 뉴로미터를 이용한 전류인지역치의 변화의 분석)

  • Park, Jin-Hyung;Ryu, Ji-Won;Ahn, Jong-Mo;Ok, Soo-Min;Yoon, Chang-Lyuk
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2010
  • The goal of this study is to contribute to the clinical application by making a quantitative nerve current perception threshold(CPT) examination for the evaluation of numbness that could be occurred after dental surgery, Measurement of CPTs at each different frequencies(2000 Hz, 250 Hz, and 5 Hz) were performed to trigeminal nerve main branch(mandibular division) of 29 patients with dental surgery on mandibular area and 25 normal subjects. There were significant differences in CPTs between patient group and control group.(p<0.05) But, there were no significant between patient male and female in both patient and control group except 2000 Hz was significantly high in the control female.