• Title/Summary/Keyword: 측정오차

Search Result 4,685, Processing Time 0.03 seconds

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Assessment of Nutrient Intakes of Lunch Meals for the Aged Customers at the Elderly Care Facilities Through Measuring Cooking Yield Factor and the Weighed Plate Waste (조리 중량 변화 계수 및 잔반계측법을 이용한 노인복지시설 이용자의 점심식사 영양섭취평가)

  • Chang, Hye-Ja;Yi, Na-Young;Kim, Tae-Hee
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.650-663
    • /
    • 2009
  • The purposes of this study were to investigate one portion size of menus served and to evaluate nutrient intake of lunch at three elderly care facility food services located in Seoul. A weighed plate method was employed to measure plate wastes and consumption of the menus served. Yield factors were calculated from cooking experiments based on standardized recipes, and were used to evaluate nutrient intake. One hundred elderly participated in this study for measuring plate waste and were asked to complete questionnaire. Nutrient analyses for the served and consumed meal were performed using CAN program. The yield factors of rice dishes after cooking are 2.4 regardless of rice dish types, 1.58 for thick soups, 0.60 to 0.70 for meat dishes, and 1.0 to 1.25 branched vegetable. Average consumption quantity of dishes were 235.97 g for rice, 248.53 g for soup, 72.83 g for meat dishes, 39.80 g for vegetables and 28.36 g for Kimchi. On average the food waste rate is 14.0%, indicating the second highest plate waste percentage of Kimchi (26.2%), and meat/fish dish (17.3%). The evaluation results of NAR (Nutrition Adequacy Ratio) showed that iron (0.12), calcium (0.64), riboflavin (0.80), and folic acid (0.97) were less than 1.0 in both male and female elderly groups, indicating significant differences of NAR among three facilities. Compared to the 1/3 Dietary Reference Intake (DRIs) for the elderly groups, nutrient intake analysis demonstrated that calcium (100%) and iron (100%), followed by riboflavin, vitamin A, and Vitamin B6 did not met of the 1/3 EAR (Estimated Average Requirement). For the nutritious meal management, a professional dietitian should be placed at the elderly care center to develop standardized recipes in consideration of yield factors and the elderly's health and nutrition status.

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

The Influence of Aging on Pulmonary Function Tests in Elderly Korean Population (한국에서 노화에 따른 폐기능지표의 변화양상)

  • Lee, Jae-Myung;Kim, Eun-Jung;Kang, Min-Jong;Son, Jee-Woong;Lee, Seung-Joon;Kim, Dong-Gyu;Park, Myung-Jae;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.752-759
    • /
    • 2000
  • Background : Many studies have shown that pulmonary function differs widely among race, age and geographical residency. By virtue of the improvement of nutrition and environment, the elderly population in Korea is markedly increasing and so are the ages of patients complaining respiratory symptoms. However, we do not have our own data on the pulmonary functional reserve of elderly persons in Korea. We evaluate the deterioration of pulmonary functional reserve and standardize the predictive values of pulmonary function in the elderly population. Method : Pulmonary function tests were conducted in 100 men and 100 women over the age of 65. We analyzed changes of FVC and $FEV_1$ according to age and height by linear regression. We compared our new multiple linear regression equation with other equations currently used in Korea. Results : In men, the mean age was $71.5{\pm}5.2$(mean${\pm}$SD) years and the mean height was $163.6{\pm}6.2$cm. The mean FVC was $3.42{\pm}0.49{\ell}$ and the mean $FEV_1, $2.72{\pm}v$. In women, the mean age was $72.0{\pm}5.1$ years and the mean height was $149.1{\pm}5.9$cm. The mean FVC was $2.22{\pm}0.42{\ell}$ and the mean $FEV_1$ $1.83{\pm}0.34{\ell}$. Multiple linear regression equation using age and height as an independent factors was as follows : FVC(${\ell}$)=1.857-0.0356$\times$age(year)+0.02517$\times$height(cm) (p<0.01, $R^2$=0.279), $FEV_1(${\ell}$)=1.340-0.02698$\times$age(year)+0.02021$\times$height(cm) (p<0.01, $R^2$=0.255) in men, FVC(${\ell}$) =-0.09765-0.03332$\times$age(year)+0.03164$\times$height(cm) (p<0.01, $R^2$=0.435), $FEV_1(${\ell}$)=-0.l69-0.02469$\times$age(year)+0.02539$\times$height(cm) (p<0.01, $R^2$=0.41) in women. Conclusion : We established prediction regressions for pulmonary functional tests in the elderly Korean population. We also confirmed that currently adopted equations do not exactly anticipate the expected pulmonary functional reserve in the aged person over 65 years old. We suggest that our new equations from this study should be applied to interpret the pulmonary function tests in the elderly population in Korea.

  • PDF