• Title/Summary/Keyword: 측정오차

Search Result 4,668, Processing Time 0.031 seconds

A Study on the Dimensions, Surface Area and Volume of Grains (곡립(穀粒)의 치수, 표면적(表面積) 및 체적(體積)에 관(關)한 연구(硏究))

  • Park, Jong Min;Kim, Man Soo
    • Korean Journal of Agricultural Science
    • /
    • v.16 no.1
    • /
    • pp.84-101
    • /
    • 1989
  • An accurate measurement of size, surface area and volume of agricultural products is essential in many engineering operations such as handling and sorting, and in heat transfer studies on heating and cooling processes. Little information is available on these properties due to their irregular shape, and moreover very little information on the rough rice, soybean, barley, and wheat has been published. Physical dimensions of grain, such as length, width, thickness, surface area, and volume vary according to the variety, environmental conditions, temperature, and moisture content. Especially, recent research has emphasized on the variation of these properties with the important factors such as moisture content. The objectives of this study were to determine physical dimensions such as length, width and thickness, surface area and volume of the rough rice, soybean, barley, and wheat as a function of moisture content, to investigate the effect of moisture content on the properties, and to develop exponential equations to predict the surface area and the volume of the grains as a function of physical dimensions. The varieties of the rough rice used in this study were Akibare, Milyang 15, Seomjin, Samkang, Chilseong, and Yongmun, as a soybean sample Jangyeobkong and Hwangkeumkong, as a barley sample Olbori and Salbori, and as a wheat sample Eunpa and Guru were selected, respectively. The physical properties of the grain samples were determined at four levels of moisture content and ten or fifteen replications were run at each moisture content level and each variety. The results of this study are summarized as follows; 1. In comparison of the surface area and the volume of the 0.0375m diameter-sphere measured in this study with the calculated values by the formula the percent error between them showed least values of 0.65% and 0.77% at the rotational degree interval of 15 degree respectively. 2. The statistical test(t-test) results of the physical properties between the types of rough rice, and between the varieties of soybean and wheat indicated that there were significant difference at the 5% level between them. 3. The physical dimensions varied linearly with the moisture content, and the ratios of length to thickness (L/T) and of width to thickness (W/T) in rough rice decreased with increase of moisture content, while increased in soybean, but uniform tendency of the ratios in barley and wheat was not shown. In all of the sample grains except Olbori, sphericity decreased with increase of moisture content. 4. Over the experimental moisture levels, the surface area and the volume were in the ranges of about $45{\sim}51{\times}10^{-6}m^2$, $25{\sim}30{\times}10^{-9}m^3$ for Japonica-type rough rice, about $42{\sim}47{\times}10^{-6}m^2$, $21{\sim}26{\times}10^{-9}m^3$ for Indica${\times}$Japonica type rough rice, about $188{\sim}200{\times}10^{-6}m^2$, $277{\sim}300{\times}10^{-9}m^3$ for Jangyeobkong, about $180{\sim}201{\times}10^{-6}m^2$, $190{\sim}253{\times}10^{-9}m^3$ for Hwangkeumkong, about $60{\sim}69{\times}10^{-6}m^2$, $36{\sim}45{\times}10^{-9}m^3$ for Covered barley, about $47{\sim}60{\times}10^{-6}m^2$, $22{\sim}28{\times}10^{-9}m^3$ for Naked barley, about $51{\sim}20{\times}10^{-6}m^2$, $23{\sim}31{\times}10^{-9}m^3$ for Eunpamill, and about $57{\sim}69{\times}10^{-6}m^2$, $27{\sim}34{\times}10^{-9}m^3$ for Gurumill, respectively. 5. The increasing rate of surface area and volume with increase of moisture content was higher in soybean than other sample grains, and that of Japonica-type was slightly higher than Indica${\times}$Japonica type in rough rice. 6. The regression equations of physical dimensions, surface area and volume were developed as a function of moisture content, the exponential equations of surface area and volume were also developed as a function of physical dimensions, and the regression equations of surface area were also developed as a function of volume in all grain samples.

  • PDF

Effect of Acute Ethanol Intoxication on the Pulmonary Compliance and Surfactant in Rats (급성(急性) Ethyl 알콜 중독(中毒) 흰쥐의 폐용압률(肺容壓率)과 폐포활성물질(肺胞活性物質)의 변화(變化))

  • Lee, Seung-Jung;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.27-36
    • /
    • 1981
  • Relatively little has been done on the metabolic changes of the lung produced by the excessive alcohol ingestion to the point of the acute alcohol intoxication. In the present study, an effort was made to clarify the possible changes of the pulmonary surfactant system by the acute alcohol ingestion. The dynamic pulmonary compliance and the levels of protein and inorganic phosphorus (Pi) of both lung lavage and extract were chosen as the parameters of the pulmonary surfactant activities. The albino rats of both sexes were used, and 1.5 ml of 50% ethanol per 100 g body weight was given by oral intubation, and the experiment was performed at 1, 3, 6, 12, and 24 hours after the alcohol ingestion. The rat was sacrificed by cutting the carotid arteries, and blood sample for the determination of hematocrit(Hct) and the blood alcohol concentration was obtained. Both lungs were completely removed without dammage to the lung tissue, and the pulmonary compliance was measured by the changes of pressure-volume(P-V) curves by inflating or deflating the lung with air. Immediately after the P-V curves were recorded, the lung lavage was obtained by washing the lobes with 15ml of isotonic saline 3 times with a syringe. Next, total lungs were homogenized and filtered to obtain the lung extract. The protein and Pi levels were measured using the lung lavage and extract as the samples, and the lung/body weight ratio(L/B ratio) was also calculated. The results thus obtained were compared with the normal values and summarized as follows. The blood alcohol concentration reached the highest level of $0.71{\pm}0.02\;g\;%$ at 1 hr and gradually decreased until 24 hrs$(0.36{\pm}0.02\;g%)$ after the alcohol ingestion, but all the experimental groups showed significant increase comparing with the normal. The highest Hct value was obtained at 1hr$(64.86{\pm}2.45%)$ and significantly elevated value was continued throughout the experiment. The L/B ratio was significantly lowered from 3hrs until 24hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The pulmonary compliance at inflation and deflation did not change appreciablly from the normal until 3 hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The protein level of the lung lavage stowed a significantly increased value of $12.36{\pm}0.35\;mg/gm(3rd hr)$, $12.70{\pm}0.74\;mg/gm(12 th hr)$, and $12.65{\pm}0.88\;mg/gm(24 th hr)$, respectively, comparing with the normal value of $10.65{\pm}0.62\;mg/gm$, and the Pi level also showed a similar tendency of significant increase at 12th hr $(7.65{\pm}0.63\;{\mu}mol/gm)$ and 24 th hr$(6.70{\pm}0.36\;{\mu}mol/gm)$ comparing with the normal value of $5.32{\pm}0.20\;{\mu}mol/gm$. The protein level of the lung extract in the alcohol group was generally similar to the normal value with a slight decrease at 1st and 3 rd hr, tut the Pi level of the lung extract was generally increased in the alcohol group, and a significant increase was observed at 6 th hr$(17.77{\pm}1.54\;{\mu}mol/gm)$, 12 th hr$(13.92{\pm}0.78\;{\mu}mol/gm)$ and 24 th hr$(14.57{\pm}0.53\;{\mu}mol/gm)$ of the alcohol ingestion comparing with the normal value of $10.34{\pm}0.37\;{\mu}mol/gm$. From the above, it may be concluded that the acute alcohol intoxication produces the metabolic changes of the lungs by the increased surfactant activities and elevated pulmonary compliance.

  • PDF

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Assessment of Nutrient Intakes of Lunch Meals for the Aged Customers at the Elderly Care Facilities Through Measuring Cooking Yield Factor and the Weighed Plate Waste (조리 중량 변화 계수 및 잔반계측법을 이용한 노인복지시설 이용자의 점심식사 영양섭취평가)

  • Chang, Hye-Ja;Yi, Na-Young;Kim, Tae-Hee
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.650-663
    • /
    • 2009
  • The purposes of this study were to investigate one portion size of menus served and to evaluate nutrient intake of lunch at three elderly care facility food services located in Seoul. A weighed plate method was employed to measure plate wastes and consumption of the menus served. Yield factors were calculated from cooking experiments based on standardized recipes, and were used to evaluate nutrient intake. One hundred elderly participated in this study for measuring plate waste and were asked to complete questionnaire. Nutrient analyses for the served and consumed meal were performed using CAN program. The yield factors of rice dishes after cooking are 2.4 regardless of rice dish types, 1.58 for thick soups, 0.60 to 0.70 for meat dishes, and 1.0 to 1.25 branched vegetable. Average consumption quantity of dishes were 235.97 g for rice, 248.53 g for soup, 72.83 g for meat dishes, 39.80 g for vegetables and 28.36 g for Kimchi. On average the food waste rate is 14.0%, indicating the second highest plate waste percentage of Kimchi (26.2%), and meat/fish dish (17.3%). The evaluation results of NAR (Nutrition Adequacy Ratio) showed that iron (0.12), calcium (0.64), riboflavin (0.80), and folic acid (0.97) were less than 1.0 in both male and female elderly groups, indicating significant differences of NAR among three facilities. Compared to the 1/3 Dietary Reference Intake (DRIs) for the elderly groups, nutrient intake analysis demonstrated that calcium (100%) and iron (100%), followed by riboflavin, vitamin A, and Vitamin B6 did not met of the 1/3 EAR (Estimated Average Requirement). For the nutritious meal management, a professional dietitian should be placed at the elderly care center to develop standardized recipes in consideration of yield factors and the elderly's health and nutrition status.

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

The Influence of Aging on Pulmonary Function Tests in Elderly Korean Population (한국에서 노화에 따른 폐기능지표의 변화양상)

  • Lee, Jae-Myung;Kim, Eun-Jung;Kang, Min-Jong;Son, Jee-Woong;Lee, Seung-Joon;Kim, Dong-Gyu;Park, Myung-Jae;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.752-759
    • /
    • 2000
  • Background : Many studies have shown that pulmonary function differs widely among race, age and geographical residency. By virtue of the improvement of nutrition and environment, the elderly population in Korea is markedly increasing and so are the ages of patients complaining respiratory symptoms. However, we do not have our own data on the pulmonary functional reserve of elderly persons in Korea. We evaluate the deterioration of pulmonary functional reserve and standardize the predictive values of pulmonary function in the elderly population. Method : Pulmonary function tests were conducted in 100 men and 100 women over the age of 65. We analyzed changes of FVC and $FEV_1$ according to age and height by linear regression. We compared our new multiple linear regression equation with other equations currently used in Korea. Results : In men, the mean age was $71.5{\pm}5.2$(mean${\pm}$SD) years and the mean height was $163.6{\pm}6.2$cm. The mean FVC was $3.42{\pm}0.49{\ell}$ and the mean $FEV_1, $2.72{\pm}v$. In women, the mean age was $72.0{\pm}5.1$ years and the mean height was $149.1{\pm}5.9$cm. The mean FVC was $2.22{\pm}0.42{\ell}$ and the mean $FEV_1$ $1.83{\pm}0.34{\ell}$. Multiple linear regression equation using age and height as an independent factors was as follows : FVC(${\ell}$)=1.857-0.0356$\times$age(year)+0.02517$\times$height(cm) (p<0.01, $R^2$=0.279), $FEV_1(${\ell}$)=1.340-0.02698$\times$age(year)+0.02021$\times$height(cm) (p<0.01, $R^2$=0.255) in men, FVC(${\ell}$) =-0.09765-0.03332$\times$age(year)+0.03164$\times$height(cm) (p<0.01, $R^2$=0.435), $FEV_1(${\ell}$)=-0.l69-0.02469$\times$age(year)+0.02539$\times$height(cm) (p<0.01, $R^2$=0.41) in women. Conclusion : We established prediction regressions for pulmonary functional tests in the elderly Korean population. We also confirmed that currently adopted equations do not exactly anticipate the expected pulmonary functional reserve in the aged person over 65 years old. We suggest that our new equations from this study should be applied to interpret the pulmonary function tests in the elderly population in Korea.

  • PDF