• Title/Summary/Keyword: 측정법

Search Result 13,161, Processing Time 0.04 seconds

Comparison of Contact Resistivity Measurements of Silver Paste for a Silicon Solar Cell Using TLM and CTLM (TLM 및 CTLM을 이용한 실리콘 태양전지 전면전극소재의 접촉 비저항 측정 비교연구)

  • Shin, Dong-Youn;Kim, Yu-Ri
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.539-545
    • /
    • 2014
  • Contact resistivity between silver electrodes and the emitter layer of a silicon solar cell wafer has been measured using either the circular transmission line method or the linear transmission line method. The circular transmission line method has an advantage over the linear transmission line method, in that it does not require an additional process for mesa etching to eliminate the leakage current. In contrast, the linear transmission line method has the advantage that its specimen can be acquired directly from a silicon solar cell. In this study, measured resistance data for the calculation of contact resistivity is compared for these two methods, and the mechanism by which the linear transmission line method can more realistically reflect the impact of the width and thickness of a silver electrode on contact resistivity is investigated.

컷오프 진단법을 이용한 고속 측정법

  • Na, Byeong-Geun;Yu, Gwang-Ho;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.201-201
    • /
    • 2011
  • 컷오프 진단법은 프로브 형태로 제작된 마이크로 웨이브 진단법으로, 간단한 수식을 통해 전자밀도, 전자온도 등의 측정이 가능하며, 장치나 분석방법이 매우 간단한 장점을 지닌다. 또한, 측정에 약 1 mW 정도의 적은 파워를 사용하여 플라즈마 상태를 거의 변화시키지 않으며, 공정 플라즈마에서도 사용이 가능하다. 그러나 컷오프 진단법을 사용한 측정은 다른 종류의 프로브와 마찬가지로, 약 1초 정도의 긴 시간이 필요로 하는 단점이 있다. 따라서 기존의 컷오프 진단법은 펄스 플라즈마나 토카막과 같이 빠르게 변하는 플라즈마를 측정하기에는 무리가 있다. 본 발표에서는 컷오프 진단법을 새로운 방법으로 구현하여 더욱 빠르게 측정할 수 있는 방법을 소개하고자 한다. 컷오프 프로브는 방사 안테나, 측정 안테나와 네트워크 분석기로 구성되어 있다. 네트워크 분석기는 두 안테나 사이의 플라즈마 투과 스펙트럼을 만드는데 쓰이며, 주파수 스캔 방법을 사용하여 스펙트럼을 만든다. 컷오프 진단법의 측정시간은 주파수 스캔에 걸리는 시간에 의해 결정된다. 본 발표에서는 측정을 빠르게 하고자 전혀 새로운 방법을 도입하였다. 펄스 형태의 단일신호를 플라즈마 투과 특성을 살피는데 이용하면 측정을 매우 빠르게 할 수 있다. 그래서 펄스제조기와 오실로스코프를 이용하여 스펙트럼을 얻는데 사용하였다. 이론적으로는 이 방법을 통해 측정시간을 수 nano second 수준으로 줄일 수 있다. 실험적으로는 micro second 정도의 시간으로 측정을 할 수가 있었으며, 동일한 스펙트럼 및 측정결과를 얻을 수 있었다. 또한 이 방법을 펄스플라즈마에 적용할 경우 수십 nano second 수준의 시간분해능으로 측정을 할 수가 있었다. 이 방법을 응용하면 토카막 언저리와 같이 매우 빠르게 변하며 반복되지 않는 플라즈마의 측정도 가능할 것으로 예상된다.

  • PDF

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

Optical methods for Particle Size and Temperature Measurements (입자크기 및 온도측정을 위한 광학적 방법)

  • 김상수;서용재
    • Journal of the KSME
    • /
    • v.33 no.12
    • /
    • pp.1069-1075
    • /
    • 1993
  • 측정기술이 발달함에 따라 실제 연소시스템에서 직접 응용할 수 있고, 시공간적으로 해상도가 높고 유동장과 온도장을 교란하지 않는 방법이 요구되고 있다. 이 글에서는 2장에서 광학적 방 법을 이용한 입자의 크기 측정법을 살펴보고, 3장에서는 광학적 방법을 이용한 온도의 측정법에 대하여 설명하고자 한다.

  • PDF

Stress Measurement around a Circular Role in a Cantilever Beam under Bending Moment Using Strain Gage and Reflective Photoelasticity (스트레인 게이지와 반사형 광탄성법을 이용한 굽힘을 받는 외팔보 시편 구멍 주위의 응력측정)

  • Baek, Tae-Hyun;Park, Tae-Geun;Yang, Min-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.329-335
    • /
    • 2006
  • It is necessary to study on the stress concentration experimentally, which is the main reason to avoid mechanical dilapidation and failure, when designing a mechanical structure. Stress concentration factor of a specimen of cantilever beam with a circular hole in the center was measured using both strain gage and photoelastic methods in this paper. In strain-gage measurement, three strain gages along the line near a hole of the specimen were installed and maximum strain was extrapolated from three measurements. In photoelastic measurement, two methods were employed. First, the Babinet-Soleil compensation method was used to measure the maximum strain. Secondly, photoelastic 4-step phase shilling method was applied to observe the strain distribution around the hole. Measurements obtained by different experiments were comparable within the range of experimental error.

재장전노심의 노물리시험중 제어봉제어능 측정방법들에 대한 통계적 추론

  • 정대욱;구본현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.80-87
    • /
    • 1996
  • 국내 가동중원전의 노물리 시험중 제어봉제어능 측정시 적용되는 측정방법들에 대해 실제 측정결과를 이용해서 통계적 분석 및 추론을 수행하였다. 1988년부터 현재까지 약 8년간 모든 발전소에서 행한 측정결과에 대해 통계적 분석 및 주요 시험변수들과의 상관관계를 분석한 결과, 다음과 같은 결론이 도출되었다. 제어봉 제어능 측정결과는 전반적으로 측정치가 예측치에 비해 작은 경향을 보이고 있다. 붕산희석법은 측정오차가 가장 작았고 임의성을 가지며, 노심의 붕산농도와 상관관계가 있다. Framatome방식의 제어봉교환법은 비교적 측정오차가 크나, 시험변수들과의 상관 관계는 가장 미약하다. CE 방식의 제어봉교환법은 Swap 방법 중에는 측정오차가 가장 작고 임의성이 있으나, 붕산농도 및 기준제어군 제어능 측정오차의 크기와 강한 상관관계를 갖는다. Westinghouse 방식의 제어봉교환법은 가장 측정오차가 크며 대부분의 측정결과에서 측정치가 작게 편향되어 있다. 그리고 시험제어군의 제어능이 작을수록 측정오차가 커지는 강한 상관관계가 있으며, 기준제어군 제어능 측정오차의 크기와도 상관관계가 있다.

  • PDF

A Study on the Corrosion Inhibitor Test Method in Acqueous Solutions (부식억제제의 부식억제능 측정법에 대한 연구)

  • 원덕수;김영근;이성민;고영태;박용수
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.45-45
    • /
    • 1999
  • 일반 구조용 탄소강은 수용액 중에 노출될 때 부식에 의한 손상을 받기 쉽다. 부식의 양지를 위한 방법으로 사용 매체 중에 부식억제제를 첨가하여 탄소강의 부식속도를 낮추는 방법은 흔히 사용되는 방법이다. 부식억제제는 부식억제의 원리에 따라 양극부식억제제, 음극부식억제제 그리 고 이들의 혼합부삭억 세제 둥 여러 종류가 목적에 따라 사용되고 있다. 일반적으로 부식억제제의 성능 평가에는 무게감량볍, 표면분석법, 분극거동측정, 부석전위, 선 형분극법에 의한 부식속도 측정 등 다양한 방법이 시도되고 있다. 이 중에서 전기화학적 평가볍 은 부삭억제제의 작용 기구 규명 등을 위하여 많이 사용되고 있다. 한편 제품의 개발 단계에서 실질적인 평가법으로 갈리 사용하고 있는 방법은 무게 감량법인데 이 방법은 전면부식에 의한 금 속 손실량을 측정하여 부식억제능을 측정하는 방법이다. 그러냐 실제로 부삭억제제가 사용되고 있는 환경에서의 부식양상을 판찰하여보면 전면부식에 의한 손상보다는 국부부식에 의한 손상이 보다 치명적언 경우를 종종 목격할 수 있다. 이러한 관점에서 가존의 무게감량법은 한계가 있다. 따라서 본 연구에서는 이러한 국부부식을 보다 효과적으로 평가하기 위해 새로운 시험법을 도 입 상용 부식억제제의 종류별로 비교하였다. 부식억제제로는 수용액 중의 부식억제제로 널리 사용되고 있는 Nalco 39L과 본 연구실에서 SK해미칼과 공동 개발한 GH-110 등에 대하여 MCA(Multiple Crevice Assembly)를 이용 틈부식 저항성을 평가하였다. 또한 박막화된 전기저항형 부석속도 측정 센서를 틈부식 형태의 부식측정 에 적용하는 연구를 행하였다. 시험에 사용한 재갚는 천연가스의 감압 온도보상용으로 운전하는 가스히터의 주 구성 재료인 저탄소강을 사용하였으며 열화된 부식억제제 용액으로 사용기간이 서로 다른 수용액들에 대하여 평가 방법을 적용하여 비교하였다 다양한 부식억 제 제 수용액을 비교한 결과 MCA(Multiple Crevice Assembly)를 이용한 틈부식 억제능 시험은 실제 현장 사험 결과와 어느 정도 일치하는 결과를 보였다. 새로운 틈부식 저항성 측정법으로 시도한 철박막을 이용 틈부식 측정법은 육안 검사를 실시하지 않고도 틈부식의 전행 여부를 확인할 수 있는 가능성을 확인하였다.

  • PDF

양전자 소멸 측정법에 의한 형광물질의 결함 연구

  • Lee, Jong-Yong;Gwon, Jun-Hyeon;Bae, Seok-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 본 연구에서는 BaSrFBr:Eu 형광물질의 결함 농도 분석을 시도하였다. 또한 동시 계수 방법과 Fast -Slow - Coincidence 시스템으로 구성한 양전자 수명 측정법을 통하여 에너지의 변화에 따른 양성자 조사에 의한 시료 결함에 따른 동시 계수 도플러법과 양전자 수명의 변화를 측정 하였으며, SRIM 시뮬레이션을 통한 에너지에 따른 양성자 투과 깊이의 변화를 연구하였다.

  • PDF