• Title/Summary/Keyword: 측정방법론

Search Result 1,802, Processing Time 0.042 seconds

A Study on Causal Relationship About the Reparations Range (손해배상범위에 관한 인과관계의 연구)

  • Choi Hwan-Seok;Park Jong-Ryeol
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.146-157
    • /
    • 2006
  • Causal relationship means what relations the result occurred have with a fact as a reason. In general, a formular that no result exists without reasons is used for the method to confirm existence and inexistence of causal relationship. Problematic causal relationships in Private Law are reparations (Article No. 393 of Private Law) due to debt nonfulfillment and reparation due to tort (Application of Article No. 393 by Article No. 750, and No. 763 of Private Law). The purpose pursued by reparation system in private law is to promote equal burden of damages, and the range of reparation at this time is decided by the range of damage and the range of damage is decided by the principle of causal relationship. That the causal relationship theory fairly causes confusion by treating one problem and the other problem as the same thing, instead of dividing them according to the purpose of protection presented by the law is a reason of the criticism from different views.

  • PDF

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF

Acid Steatocrit in Korean Infants (한국 영아의 Acid Steatocrit에 대한 연구)

  • Park, Ji He;Chung, So Chung;Song, Jun Soup;Kim, Kyo Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.3
    • /
    • pp.320-324
    • /
    • 2002
  • Purpose : Steatorrhea tests have been developed using various methods. Acid steatocrit is a simple method to detect steatorrhea and has very high sensitivity and specificity. This present study was designed to establish the normal values of acid steatocrit in Korean infants and to find the difference according to the various feeding methods. Methods : Acid steatocrit tests were conducted on 128 infants who were under 12 months of age and who had non-specific gastrointestinal diseases between May 1998 and April 2001. The results were classified into neonatal ages(79 neonates), 1-6 months(28 infants), 7-12 months(21 infants). This included formula-fed(46 neonates) and human milk-fed(33 neonates), 1-6 months formula-fed (18 infants) and human milk-fed(10 infants), 7-12 months formula-fed(11 infants) and human milk-fed(10 infants). Results : The acid steatocrit values decreased by infant age in months. Acid steatocrit values decreased much more after 7 months of ages. The acid steatocrit values of human milk-fed infants were significantly lower than those of formula-fed infants. Conclusion : Our study confirms that a physiologic steatorrhea was found in the infant period and decreases by infant age of months. The acid steatocrit test might be useful for the evaluation of gastrointestinal milk fat malabsorption disorders and therapeutic effects.

A Case Study on the Estimation of Forest Work Load Index in the Type of Forest Tending Operation (숲가꾸기사업 유형별 산림작업부하지수 추정을 위한 사례연구)

  • Sung-Min Park;Hyeong-keun Kweon;Sung-Min Choi
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.3
    • /
    • pp.303-321
    • /
    • 2023
  • To develop the Forest Work Load Index (FWLI) for estimating the work intensity of forest workers, a study focused on forest tending was conducted. To estimate the FWLI, we used the Ovako Working Posture Analysis System (OWAS) and the Work Load Index (WLI). The OWAS is a prominent method used for analyzing musculoskeletal load in work tasks, and WLI is a prominent method used for analyzing the work intensity of workers. The PRI values analyzed for each forest tending project were 185.3 (Thinning), 150.6 (Pruning), 181.1 (Thinning for Forest Fire Prevention), and 197.0 (Thinning for Young Trees). The WLI values, calculated on the basis of the measured heart rates, were 59.5% (Thinning), 53.5% (Pruning), 56.2% (Thinning for Forest Fire Prevention), and 62.3% (Thinning for Young Trees). The FWLI was calculated using the analyzed PRI and WLI values. The FWLI values for the forest tending project were 110.2 (Thinning), 80.7 (Pruning), 102.1 (Thinning for Forest Fire Prevention), and 123.0 (Thinning for Young Trees). The FWLI developed in this study can be used to quantitatively compare the workloads of forest workers. In the future, the analyzed FWLI can be used as a basis for improving forest workers' postures and comparing workloads across different forest projects.

Comparison and Optimization of Flux Chamber Methods of Methane Emissions from Landfill Surface Area (매립지 표면의 메탄 발산량 실측을 위한 플럭스 챔버의 방법론적 비교와 최적화)

  • Jeong, Jin Hee;Kang, Su Ji;Lim, Jong Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.10
    • /
    • pp.535-542
    • /
    • 2016
  • As one of the most cost-effective methods for surface emission measurements, flux chamber method has been used worldwide. It can be classified into two types: SFC (with slope method) and DFC (with steady-state method). SFC (static flux chamber) type needs only simple equipment and is easy to handle. However, the value of flux might vary with SFC method, because it assumes that the change of concentration in chamber is linear with time. Although more specific equipments are required for DFC (dynamic flux chamber) method, it can lead to a constant result without any ambiguity. We made a self-designed DFC using a small and compact kit, which recorded good sample homogeneity (RSD < 5%) and recovery ( > 90%). Relative expanded measurement uncertainty of this improved DFC method was 7.37%, which mainly came from uncontrolled sweep air. The study shows that the improved DFC method can be used to collect highly reliable emission data from large landfill area.

An Evaluation Model of Information Quality of UCC Service Site (UCC 서비스 사이트의 정보품질 평가 모델 개발)

  • Kang, So-Ra;Kim, Yoo-Jung;Lee, Hyun-Ju;Moon, Yoon-Ji;Kim, Woo-Dy
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2818-2826
    • /
    • 2010
  • This research was conducted to develop a model appropriate for the measurement of information quality of UCC service site. The evaluation factors that reflect more improvement of the information utilization capability were verified. Enhancement of information utilization capability can control greater amount of information among the users and site companies, and among users. Therefore, Wikipedia, for example, provides a Web 2.0 based information quality that is more advanced than Web 1.0 by allowing effective control of information among the users. This type of information quality presents 'information reliability' and 'information stability' as evaluation factors added to the factors such as 'information sufficiency' and 'information usability.' Information reliability and information stability are essential factors that need to conduct an evaluation in the Web 2.0 environment that can distribute greater number of information in the environment where all the users serve as participants. Moreover, 'interesting information' and 'originality of information' suggests that information itself should include the attributes that can attract the attention of users, due to the nature of the Attention Economics, which points out one of the Web 2.0 phenomenon that the number of information consumers is smaller than that of information suppliers.

Validation of enzyme immunoassay for the quantitative measurement of human IgG antibodies specific for Haemophilus influenzae Type b capsular polysaccharide (Haemophilus influenzae type b 피막 다당질 특이 인간 IgG 항체의 정량적 측정을 위한 enzyme immunoassay의 타당성 연구)

  • Kim, Kyung Hyo;Lim, Soo Young
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.2
    • /
    • pp.143-150
    • /
    • 2007
  • Purpose : This study was conducted to validate enzyme immunoassay (EIA) for the quantitative measurement of human IgG antibodies specific for Haemophilus influenzae type b (Hib) capsular polysaccharide. Method : We evaluated specificity, repeatability, intermediate precision, accuracy, lower limit of quantification (LLOQ), and stability to validate standardized EIA for the quantitative measurement of human anti-polyribosylribitol phosphate (PRP) IgG antibodies. Results : The results indicated that this EIA showed specificity to HbO-HA antigen and repeatability and intermediate precision were within acceptance criteria (repeatability: $CV{\leq}15%$, intermediate precision: $CV{\leq}20%$). The EIA-derived results from this laboratory were equivalent to those obtained by the standard radioactive antigen binding assay (RABA) for quantitation of anti-PRP antibodies in the 28 sera. Spiking recovery result was within acceptance criteria ($100{\pm}20%$). The precision and accuracy of samples in LLOQ were from -14.7 to -4.7% in nominal values, which were within acceptance criteria (precision: $CV{\leq}25%$, accuracy: ${\pm}25%$). Freeze-thaw stability and short term temperature stability were within ${\pm}20%$ of acceptance criteria. Conclusions : The EIA which is performed at the Center for Vaccine Evaluation and Study Ewha Medical Research Institute, is an appropriate serologic assay which can be used for quantitation of anti-PRP IgG antibodies in human sera.

Measuring the Corporate Readiness to Address Climate Challenges : Developing an Index of Climate Competitiveness (기업경쟁력에 미치는 기후변화의 영향 : 경쟁력 결정요인과 측정지표 개발)

  • Lee, Myung-Kyoon;Kim, Hoseok
    • Environmental and Resource Economics Review
    • /
    • v.19 no.2
    • /
    • pp.383-411
    • /
    • 2010
  • Climate change and related policies and regulations influence the performance of the firms in various ways. Climate change influences corporate competitiveness through physical impacts, GHG regulations, changes in asset values, demand shift, etc. Therefore, corporate competitiveness could be maintained by reducing vulnerability to climate change and adapting to new circumstances. Without effective responses to the challenges, the firms would have difficulties in maintaining their competitiveness in the market and the cost of national economy will significantly increase as well. Even though it seems fairly easy to understand the meaning of competitiveness, deriving the driving forces of and measuring changes in competitiveness are complicated and disputable processes. A common way to overcome it is to develop a 'competitiveness index'. The objective of this study is to derive the main factors influencing corporate competitiveness related to climate change and develop 'competitiveness index' reflecting those factors. The index will make contribution to enhance the response capacity of the firms to climate change and increase the effectiveness of climate change policies for the industry by providing a quantitative tool to measure the changes in corporate competitiveness related to climate change.

  • PDF