• Title/Summary/Keyword: 측정기준

Search Result 7,125, Processing Time 0.037 seconds

Absolute Test for a 4-inch Flat and Its Measurement Uncertainty (4인치 평면의 절대 측정 및 측정불확도 계산)

  • Kim, Su-Young;Song, Jae-Bong;Yang, Ho-Soon;Rhee, Hyug-Gyo
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.6
    • /
    • pp.339-345
    • /
    • 2017
  • The flatness of a reference flat plays an important role, from the calibration of an interferometer to the reference for a semiconductor or flat-panel display, etc. Especially if we order the flatness measurement outside Korea, we may spend more time and money. In this paper, we measured the flatness of a reference flat using a three-flat test, which is one of the absolute measurement methods, and calculated its measurement uncertainty. In the three-flat test we adopted, each flat is tested against another flat, with three unknown flats, using an interferometer. Among several three-flat tests, we adopted Griesmann's method which has a low measurement uncertainty and is less dependent on the experimental equipment. As a result, the measurement uncertainty was found to be less than 0.5 nm rms, which is very accurate for high-tech industrial applications.

Hydrological survey and analysis considering field conditions (현장여건을 고려한 수문조사 및 분석)

  • HwangBo, Jong-Gu;Yu, Young-moo;Jeong, Chan-Woong;Lee, Sang-Ho;Seo, Jeong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.265-265
    • /
    • 2022
  • 유량조사는 측선수, 측정시간, 측정위치, 측정방법 등 많은 기준이 있으며 이를 잘 준수하는 것이 높은 품질의 유량측정 성과를 확보하는 방법이다. 그러나 이러한 기본적인 기준을 잘 준수하더라도 현장 상황에 따라 유량측정 성과에 오차가 포함 될 수 있다. 본 연구에서는 상류 소수력발전소의 방류량에 따라 유량이 변화하고 수위관측소 부근에 큰 저류공간이 있는 현장 여건이 유량측정성과에 어떠한 영향을 끼치는지 검토하였다. 홍천군(주음치교) 관측소는 홍천강 상류에 위치하며 소수력발전소의 운영에 따라 관측소를 흘러가며 그 유량이 소수력발전소의 영향으로 점변한다. 일반적으로 이러한 경우 측정시간을 최대한 짧게 가져가 유량자료의 정확도를 확보한다. 하지만 홍천군(주음치교)의 경우 수위관측소 주변에 큰 저류공간이 있어 이를 동시에 고려해야 하며 단순하게 측정시간을 짧게 하는 것만으로는 측정성과의 품질을 확보 할 수 없다. 왜냐하면 이 저류 공간으로 물이 유입되는 시간동안은 수위관측소의 수위 상승은 미미하지만 하천 유량은 증가하는 부등류가 발생한다. 유량측정은 등류가정에 의한 것으로 수위관측소 주변이 부등류가 발생하면 유량측정 성과에 큰 오류가 나타나기도 한다. 홍천군(주음치교)에서 현장 상황이 등류일 때와 부등류일 때 모두 측정을 실시하였으며 그 차이를 확인하였다. 저류공간의 물 유입이나 유출이 없는, 즉 등류 상태의 유량측정 성과는 수위-유량관계식과 2.86%차이를 보였으며 부등류 상태의 유량측정 성과는 19.85%차이를 보여 큰 차이를 보였다(기준수위 0.49m). 또한 소수력발전소 운영에 따라 유량 상승 시에는 수위-유량관계곡선식 대비하야 양(+)의 편차율이 발생하고, 유량이 하강 시에는 수위-유량관곡선식 대비 음(-)의 편차율 발생하는 것으로 나타났다. 소수력 발전소는 동절기를 제외한 상시 운영으로 홍천군(주음치교) 관측소의 정확한 수위-유량관계식을 확인하기 위하여 소수력 발전소 운영을 중단하고 측정을 실시하였으며 유량변동을 멈추고, 즉 등류 흐름에서 측정한 성과는 수위-유량관계식과 차이가 1.06% 불과한 것으로 나타났다. 수문조사는 측선수, 측정시간, 측점수 등 많은 기준이 있다. 그러나 이러한 측정기준과는 별개로 현장은 다양한 조건이 발생하며 측정성과의 정확도에 영향을 끼치는 경우가 발생하기도 한다. 따라서 유량측정 기준을 잘 준수하는 것도 중요하지만 현장상황을 파악하고 이에 적절한 유량측정을 실시해야 그 오차를 최소화 할 수 있다.

  • PDF

Evaluation of Hygienic Status of University Foodservice Operation using ATP bioluminescence Assay (ATP bioluminescence Assay를 이용한 대학 급식시설의 위생상태 평가에 관한 연구)

  • 박영숙
    • Korean journal of food and cookery science
    • /
    • v.16 no.2
    • /
    • pp.195-201
    • /
    • 2000
  • An investigation was conducted to evaluate the hygienic status of university foodservice operation by using conventional swabbing technique plus standard plate count and ATP bioluminescence assay. The results of the study were as follows: 1) For all kitchen boards, knives, feeding trays, and dish towels tested, there was an overall agreement at 84.7% level between the results obtained using ATP bioluminescence and plate count when using a pass/fail cut-off of 3$\times$ control values for ATP assay and 40 CFU(colony forming unit)/㎠ for plate count. 2) The agrement rate between ATP assay and standard plate count was 87.5% for the samples before use, 29.2% for those during use, and 42.7% for those after cleaning and sanitizing. 3) The plate counts of three university foodservice operations for kitchen board, kitchen knife, feeding tray and dish towel were within the acceptable limits when tested before using. However, none of them were within the acceptable limits when tested during using and after cleaning and sanitizing. 4) Above results suggested that an immediate action needs to be taken to reduce the potential danger of cross-contamination and also effective sanitary control methods needs to be developed to improve the sanitary condition.

  • PDF

Measurement and Evaluation of VDT Electo-magnetic Wave (VDT 전자파의 측정 및 평가)

  • 박재희;김진호;김철중;조춘수
    • Proceedings of the ESK Conference
    • /
    • 1993.10a
    • /
    • pp.38-45
    • /
    • 1993
  • VDT는 저주파 대역에서 인체에 해롭다고 여겨지는 전자파를 발생시키고 있다. 선진제국에서는 VDT에 서 발생하는 전자파를 규제하기 위해 VDT 전자파 측정방법의 표준화와 안전 규제 등을 실시하고 있다. VDT와 관련한 대표적인 측정기준으로는 스웨덴의 MPR 기준이 있다. 본 연구에서는 MPR 기준에 의거 VDT의 전기장, 자기장 모두에 대해 거리별, 방향별, 높이별 세기를 측정하였다. 또한 VDT 전자파의 상대적 세기를 알아보기 위해 다른 전기제품인 전기담요, 헤어드리이어 등에 대한 비교측정도 수행하였 으며, 보안경의 전자파 차폐효과도 측정하였다. 측정결과, VDT 전기장은 전면에서 세기가 가장 크며, 후면으로 갈수록 작아지는 것으로 나타났으며, 자기장은 ELF 대역은 양측면에서, VLF 대역은 전면에서 그 크기가 가장 큰것으로 나타났다. 전기제품과의 비교에서는 VDT의 전기장, 자기장은 전기담요, 헤어 드리이어 등에 비해 크지 않은 것으로 나타났으며, 보안경은 접지해서 쓸때만 전기장 차폐효과가 큰것 으로 나타났다.

  • PDF

Minimization Method of Measurement Noise for Satellite Clock Anomaly Detection (위성시계 이상검출을 위한 측정잡음 최소화 기법)

  • Seo, Kiyeol;Park, Sanghyun;Jang, Wonseok;Kim, Youngki
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.505-510
    • /
    • 2013
  • In order to detect and identify the GPS clock anomaly in the Differential GPS real environment, this paper addresses a method for minimizing the measurement noise of reference receivers. It estimates the real measurement noise that removed the uncommon error source from pseudorange measurement to minimize the measurement noise. Based on the output of two reference receivers, it first removes the uncommon errors, then optimizes the measurement noise by applying the correction data. Finally, it detects and identifies the satellite clock anomaly using the minimized measurement noise. The method will increase the availability of current DGPS reference system.

Study on Method for Measuring Partial Hausdorff Distance between Spatial Objects for Updating GIS OB (GIS DB 갱신을 위한 공간 객체간 Partial Hausdorff Distance 측정 방법 연구)

  • Bang, Yoon-Sik;Huh, Yong;Choi, Jae-Wan;Yu, Ki-Yun
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.06a
    • /
    • pp.419-426
    • /
    • 2008
  • 본 논문에서는, 건설도면의 건물 경계선을 이용하여 기존 지형도의 건물 레이어를 자동 갱신하는 과정에서 건물 객체간 유사를 측정하는 과정에서 Hausdorff 거리 측정 방법을 적용해 보았다. 서로 다른 축척에 의하여 발생하는 형상의 세일도 차이에서 발생하는 오차를 최소화하기 위하여 partial Hausdorff 거리를 적용하였다. 이 때 partial fraction을 정의하기 위한 기준으로 폴리곤 절점, 경계선 길이, 폴리곤 면적을 이용한 세 가지 방법을 적용하였다. 이 기준을 실제 데이터에 적용한 결과, 경계선 기준과 폴리곤 면적 기준 방법이 절점 기준에 비하여 안정적이라는 것과, 적용 기준에 따라 적절한 partial fraction 값을 사용하면 잡음에 의한 영향을 최소화할 수 있다는 것을 확인할 수 있었다.

  • PDF

Practical Application of Continuous Suspended Sediment Concentration Measurement using H-ADCP (H-ADCP를 활용한 연속적인 부유사농도 측정 방법의 실용화)

  • Geunsoo Son;Youngsin Roh;Dongsu Kim;Suin Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.134-134
    • /
    • 2023
  • 하천의 유사량 측정은 수량·수질 관리에 있어 유량 자료와 함께 필수적인 자료로 다지점에서 연속적으로 측정된 자료가 필요하다. 하지만 현재 부유사 측정 방법은 부유사채집기를 통해 조사가 이루어져 인력, 비용, 안전의 문제로 지점 확대와 연속 측정이 어려운 상황이다. 이러한 문제를 해결하기 위한 대안으로, 센서 기반의 유사량 측정 기술이 개발되어 실용화를 위한 연구들이 수행되고 있다. 특히, 연속적인 유량측정을 목적으로 사용되고 있는 자동유량관측소에 설치된 H-ADCP의 초음파산란도를 이용한 부유사농도 측정 방법은 기 구축된 인프라를 활용하므로 경제적으로 유리하며, 유량자료를 동시에 측정하므로 실시간의 부유사량 자료를 생산할 수 있는 장점이 있다. 이에 본 연구에서는 국가하천에 설치되어 운영 중인 자동유량관측소 H-ADCP의 초음파산란도를 활용하여 연속적인 부유사농도 측정을 위한 기술 개발과 기술 적용을 위한 기준 및 지침을 마련하고자 하였다. 초음파산란도를 활용한 부유사농도 측정 방법의 적용성 검토를 위해 2015년부터 2022년까지 자동 관측소 기준 유사량 측정이 이루어진 지점을 대상으로 자료를 수집하여 지점별 초음파산란도-부유사농도 관계식을 개발하여 분석을 수행하였다. 그리고 테스트베드에서 실시간 운영을 통해 초음파산란도를 활용한 부유사농도 측정 방법의 기술 개선과 분석 절차 및 기준 등 실무적 고려사항을 검토하여 실용화를 위한 지침 및 표준안을 마련하고자 하였다. 본 연구결과를 통해 기존 부유사채집기와 정확도를 분석한 결과, 기존 부유사대비 약 80%의 측정정확도를 보이는 것으로 나타났으며, 10분 간격의 부유사농도의 측정을 통해 홍수기 유사의 이력현상의 분석이 가능함을 확인 할 수 있었다. 추후에는 본 연구 성과를 통해서 개발한 기술을 시범 확대 적용하여 지속적인 기술의 개선과 측정기준을 제시하고, 유지관리 등에 대한 검토를 수행할 예정이며, 실용화를 통해 유사량 조사지점의 확대와 연속적인 유사량 자료를 생산하는데 기여할 것으로 기대된다.

  • PDF

River discharge measurement and analysis for Nakdong-river basin in 2008 (2008년 낙동강 유량측정 및 유출특성 분석)

  • 유량조사사업단 유량조사실 낙동강그룹
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1889-1893
    • /
    • 2009
  • 수자원을 효율적으로 관리하고 이용하여 홍수 피해를 저감하고 환경친화적인 수자원의 역할을 제대로 자리매김하기 위하여 무엇보다 필요한 사항은 신뢰성 있는 유량자료를 기초자료로 확보하는 것이다. 그러나 기존의 유량 측정은 측정기준의 불명확, 예산과 측정장비의 부족, 전문 인력의 부재로 인해 유량자료의 신뢰성에 대한 문제가 지속적으로 제기되어 왔다. 따라서 정도 높은 유량 자료를 생성하고자 최근 유량조사사업단의 설립과 함께 유량측정을 전문적으로 담당하는 인력이 국내 주요지점에 대한 유량측정과 분석을 일상적으로 수행하는 등 유량자료의 품질의 개선노력이 계속되고 있다. 본 연구는 강화된 유량측정 기준과 개선된 방법론에 따른 현장측정을 통해 정밀한 유량측정성과를 확보하여 측정된 유량측정성과의 일상 검증을 통해 보다 정밀한 유량측정성과를 확보하고자 하였다. 또한, 유량측정 전 과정이 적절하게 이루어졌는지를 평가하여 낙동강권역의 신뢰성 있는 수위-유량관계곡선을 개발하였으며 개발된 곡선식을 이용하여 유량자료를 생성하고 유출률 분석 등을 통해 2008년 낙동강권역의 유출특성을 검토하였다. 2008년 낙동강권역의 유출특성은 낙동강 상류 및 동해 및 남해지역에 집중된 강수분포와 높은 가뭄지수로 인해 2008년 발생한 호우사상은 침투 및 증발에 의한 손실에 따라 유출량이 적게 평가되어 평균유출률은 약 30% 내외로 작게 산정되고 있는 것으로 나타났다.

  • PDF

Summary of survey for cave scale (동굴의 규모 측정에 대한 소고)

  • 홍시환
    • Journal of the Speleological Society of Korea
    • /
    • v.41 no.42
    • /
    • pp.51-54
    • /
    • 1995
  • 동굴의 규모나 동굴이 길이, 그 밖에 생성 연대가 언제인가 하는 문제는 동굴이 발견될 때마다 제기되는 의문점이다. 그럼에도 불구하고 지금까지도 이들 동굴에 대한 규모, 길이, 생성 연대등의 측정 기준은 획일적이고, 정확한 기준이 마련되어 있지 않은 실정이다. 그리하여 여기서는 현재까지 사용되어 온 일반적인 관례에 따라 그 몇가지 기준을 소개하고 이에 대한 많은 관심을 제의하는 바이다.(중략)

  • PDF

Improvement to the Methods of Discharge Computation from Float Measurements (부자측정에 의한 유량산정방법 개선)

  • Hwang, Seok-Hwan;Kim, Chi-Young;Jung, Sung-Won;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.852-857
    • /
    • 2006
  • 하천유량자료는 이수, 치수, 수질관리 등의 목적으로 널리 사용되기 때문에 여러 가지 수문관측 자료 중 가장 중요하다고 할 수 있다. 그러나 우리나라의 유량자료는 여러 가지 한계를 가지고 있어서 수문자료로서 제대로 사용되지 못하고 있는 실정이다. 특히 홍수기 부자측정 방법에 의해 산정된 유량자료는 측정 여건, 방법, 기기 등의 한계로 인해 그 정확도가 더욱 낮다. 홍수기 부자측정 방법에 의한 유량자료의 정확도 향상을 위해서는 현장 유량측정의 정확도를 향상시키는 것이 일차적으로 필요하지만, 측정된 자료를 과학적이고 체계적인 계산과정을 통하여 유량으로 환산하는 것도 매우 중요하다. 국내의 경우 일반적으로 여름에 집중호우가 빈발하고 경사가 급한 산지하천이 많다. 그래서 홍수시 하천의 유속이 매우 빠르고 하천수내에 부유물이 많이 함유되어 있다. 이러한 요인들로 의해 대부분 홍수시 유속계를 이용한 유량측정이 불가하여 대안으로 부자를 이용하여 측정하고 있다. 그 결과 평저수시 유속계 이용시에 비해 측정 및 산정과정에서 매우 큰 오차가 발생하고 있다. 이와 같이 국내의 경우 홍수시 유량측정을 위해 부자에 전적으로 의존하는 현실임에 불구하고 부자를 이용한 유속측정 및 유량산정에 대한 연구는 매우 미흡하였다. 외국의 경우도 부자 측정에 대한 방법론이 ISO 748과 일본수문관측에 간략하게 설명되어 있고 USGS와 WMO에서는 거의 내용을 다루고 있지 않고 있다. 현재 우리나라의 경우는 ISO 748을 일부 참조하고 대부분 일본수문관측 기준에 준해 측정을 하고 있다. 자연하천임을 감안하면, 부자에 의한 유속 측정시 발생할 수 있는 여러 오차들의 경우 적절한 구간의 선택, 충분한 측선수의 확보 등과 같은 측정기준의 개선을 통하여 상당부분 제거가 가능하다. 그러나 부자를 이용해 측정된 성과를 신뢰도 높은 유량으로 산정하기 위해서는 정확한 측정과 더불어 과학적이고 표준화된 유량산정 기준과 절차가 필요하다. 본 연구에서 분석된 결과에 의하면 부자유선 모임, 홍수터 유속 미측정, 기준 흘수 미적용 등과 같은 측정 자체의 문제점을 제외하면, 부자측정 방법에 의한 유량산정시 가장 큰 오차원인은 홍수시 측정된 유속측선의 위치와 홍수 전후로 측정된 횡단면상의 위치가 일치하지 않는 점과, 대부분 두 측정 구간의 평균값을 대푯값으로 사용한다는 점이다. 본 연구는 다년간의 유량 측정 및 검증 경험과 자료를 토대로 현장에서 부자를 이용하여 측정된 측정성과를 정확도 높은 유량자료로 산정하는데 있어서의 문제점을 도출하고, 이로 인해 발생하는 오차를 추정하여 그 개선방안을 제시해 보고자한다. 더불어 보다 정확한 유량 산정을 위한 기준과 범주를 제시하고자 한다.

  • PDF