• Title/Summary/Keyword: 측정기준

Search Result 7,169, Processing Time 0.038 seconds

A Design of Stress Measurement System using Facial and Verbal Sentiment Analysis (표정과 언어 감성 분석을 통한 스트레스 측정시스템 설계)

  • Yuw, Suhwa;Chun, Jiwon;Lee, Aejin;Kim, Yoonhee
    • KNOM Review
    • /
    • v.24 no.2
    • /
    • pp.35-47
    • /
    • 2021
  • Various stress exists in a modern society, which requires constant competition and improvement. A person under stress often shows his pressure in his facial expression and language. Therefore, it is possible to measure the pressure using facial expression and language analysis. The paper proposes a stress measurement system using facial expression and language sensitivity analysis. The method analyzes the person's facial expression and language sensibility to derive the stress index based on the main emotional value and derives the integrated stress index based on the consistency of facial expression and language. The quantification and generalization of stress measurement enables many researchers to evaluate the stress index objectively in general.

고체 팬톰을 이용한 방사선치료계획시스템의 정도관리

  • 이상훈;조광환;조삼주;최진호;추성실;권수일;신동오
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.65-65
    • /
    • 2003
  • 목적 : 방사선치료기술이 날로 발전함에 따라 방사선치료계획시스템에 대한 주기적인 정도관리의 필요성은 증대하고 있으나, 국내 실정에 적합한 표준화된 정도관리절차서가 없는 실정이다. 따라서 본 연구에서는 방사선치료계획용 시스템에 대한 정도관리용 고체팬톰을 제작하여 주기적인 정도관리 활용 및 절차서를 제시하고자 한다. 대상 및 방법 : 체윤곽 보정을 위한 삼각기둥 모형 (30cm$\times$30cm$\times$5cm, 30cm$\times$15cm$\times$5$\times$) 및 정형ㆍ부정형, 불균질 측정이 가능한 물등가고체팬톰을 제작하였고, 컴퓨터단층촬영(AcQsim)을 통해 영상을 얻었으며, RTPS(AcQplan)에 입력하여 영상 내 기준점에서의 선량값을 계산하였다. RTPS를 통해 계산된 값의 평가를 위해 동일한 조건하에서 각 기준점에 대한 실제 측정을 이온함을 이용하여 측정하였다. 평가 항목으로는 정방형 조사면, 부정형 조사면, 쐐기 조사면, 불균질 물질 보정, 사방향 조사 등에 대해서 알고리즘별로 수행하였다. 결과 : RTPS를 이용하여 계산된 값과 실제 측정한 값을 비교하여 RTPS의 정확성을 평가한 결과로 합성의 불확도 허용 기준 (3%), 선속 중심축 상에서의 허용 기준 (2%) 등, 선진 각국 및 각 학회에서 권고하고 있는 허용 범위 내에서 잘 일치하였다. 결론 : RTPS는 측정된 심부선량과 선량분포 등 물리적인 인자에 의존하는 제한성이 있고, 실제로 선량계산 알고리즘과 기하학적 변화에 따라 계산값과 측정값 간에 차이가 발생할 수 있었다. 실제 인체의 체윤곽 불균일성과 불균질성을 모사한 팬톰을 제작하여 이용함으로써 다양한 RTPS간의 비교를 통한 치료 선량의 정확성을 평가하고, 방사선 치료의 원활하고 정확한 수행을 위해 실용적이고, 보편적인 치료계획 시스템의 정도관리 방법과 절차서를 수립하는데에 유용할 것으로 사료된다.

  • PDF

APMP (Asia Pacific Metrology Programme) Regional Intercomparison Results of Acoustic Calibrators (음향교정기의 아시아.태평양 지역 국제비교 결과)

  • 서상준;서재갑;조문재
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.463-471
    • /
    • 2003
  • The results of the APMP (Asia Pacific Metrology Programme) regional intercomparison of acoustic calibrators were reviewed and analyzed. The artefacts used in intercomparison are a sound level calibrator and a pistonphone. The microphones used to measure the output pressure level are 1" and 1/2" standard microphones (LS1P, LS2P) as well as 1" and 1/2" reference microphones (WS1P/F, WS2P/F). The results obtained using standard microphones are satisfactory, but those obtained by the reference microphones, even though E/sub n/ values are within ±1.0, showed great deviations. Such results had come from the inaccurate calibration of reference microphones. By using the correct calibration results which were obtained by the recently established international standards, the new results were very similar to those of the foreign standard institutes.

Analysis of very close-range photogrammetry by non-metric camera (비측정용 사진기에 의한 초근접 사진해석)

  • 강준묵;오원진
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.8 no.2
    • /
    • pp.23-29
    • /
    • 1990
  • Non-metric camera is more profitable than metric camera for geometric analysis of small and elaborate structures, because focal length control of non-metric camera is flexible while generally metric camera has limited focal length. And if the problem of conventional method requiring much time and endeavor to measure three dimensional positions of control points will be solved effectively, it is possible to analyze very close-range photogrammetry more easily and quickly. The purposes of this study are to propose the efficiency of non-metric camera and to reduce difficulty of control survey sharply by introducing self-control survey method. For these, very close-range photographs of the small object were obtained by using non-metric camera calibrated for systematic errors and then bundle adjustment is used for analysis procedure. As a result, the superiority of non-metric camera in analyzing very close-range photographs and the application proptriety of self-control survey were proved, therefore it is expected to be able to apply to precise analysis of small structures or spearhead parts.

  • PDF

Fuzzy-based Decision Support Model for Determining Preventive Maintenance Works Order (퍼지 집합을 활용한 건물 사전 보수작업 대상 선정 지원모델)

  • Ko, Taewoo;Park, Moonseo;Lee, Hyun-Soo;Kim, Hyunsoo;Kim, Sooyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.51-61
    • /
    • 2014
  • Preventive maintenance of buildings has increased the importance of interest in that it is able to maintain the performance building has and to prevent a problem occurred in future. For improved preventive maintenance work, it should be performed to select works order clearly and preceded the accurate measurement for the state of works order. when measuring the conditions, measurement of the state of work order considering the various criteria is more effective than to measure by only criterion. But, there are something hard to evaluate exactly between the criteria because of decision-maker's subjective judgments. To solve these problems, this research proposes decision making support model to determine preventive maintenance works order using Fuzzy-sets. By using Fuzzy-sets when measuring state of work objects, it can be reduced vagueness of judgments by decision-makers. This model can be used as a tool for objective evaluation of preventive maintenance work orders and offer the guideline to perform decision-making.

A Study on the Technical Regulation of Radio Equipment for EAS System (EAS 시스템을 위한 무선기기 출력기준에 관한 연구)

  • Park, Hyoung-Keun;Kim, Sun-Youb;Ra, Yu-Chan
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.968-972
    • /
    • 2009
  • 본 논문에서는 8.2MHz 대역의 국내 미약 전계 강도 무선기기의 출력제한치를 다른 외국의 기준치와 비교하였다. 이를 통해 국내의 규정이 미국이나 유럽에 비해 낮음을 확인하였고, 이를 검증하기 위해 8.2MHz EAS 시스템의 출력을 측정하였다. 측정 결과, 전계강도값이 각각 $70.6dB{\mu}V/m$$68.3dB{\mu}V/m$로 측정되었는데, 이러한 값은 국내의 현재 기준인 $102.7dB{\mu}V/m$를 초과하는 값임을 확인하였다. 따라서 8.2MHz 대역의 국내기준의 사양 검토가 필요하다고 사료된다.

  • PDF

Measurement of Harmonic Level in Low-Voltage System (저압 배전계통의 고조파 현황 분석)

  • Kang, Moon-Ho;Song, Yang-Hyao;Lee, Hyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.386-387
    • /
    • 2008
  • 정보통신기술과 디지털기술의 발전으로 수용가의 설비의 전기적인 내성은 낮아지고 있는 반면 배전계통의 외란은 증가하고 있다. 특히 고조파는 변압기 등 기기의 수명저하와 원판형계전기 오동작 등의 원인이 되고 있어 배전계통의 고조파 현황분석은 매우 중요한 의미를 갖는다. 한국전력공사에서는 연구과제의 수행을 통해 2006년부터 1년간 저압 배전계통의 고조파 현황을 측정하고 이를 분석하였다. 측정개소는 기준임피던스의 기준이 되는 저압측 전력량계 1차측으로 하고 전국 100 개소를 부하특성에 따라 선정하였다. 1년간 측정한 고조파를 차수별로 분석한 결과 영상분에 해당하는 9차와 15차 고조파가 IEC61000-3-6의 저압계통 고조파 기준과 비교하여 높게 나타났다.

  • PDF

TTA 시험$\cdot$인증 서비스 - 네트워크장비 분야 - ㈜브레인투엔티원 NetHole AG800 VoIP, Gateway TTA Verified 인증 획득

  • 유지원;장웅
    • TTA Journal
    • /
    • s.85
    • /
    • pp.158-162
    • /
    • 2003
  • TTA(한국정보통신기술협회)는 2002년 11월 26일 ㈜브레인투엔티원(www.brain21.com)의 VoIP Gateway(모델명: NetHole AG800)에 대하여 기능 및 성능시험을 수행하여 TTA Verified 인증서(번호: TTA-V-02-003)를 발급하였다.TTA는 ㈜브레인투엔티원의 NetHole AG800 Gateway에 대한 기능확인 및 성능평가를 위해 H.323 VoIP 소용량 Gateway TTA Verified 인증기준에 따라 54개의 시험항목을 측정하였다. 본 고에서는 Cisco AS5400 Gateway, Cosmobridge CMC3000 Gatekeeper, Cosmobridge CTG3400 Gateway와 연동하여 그 기능이 TTA Verified 시험인증 기준에 따라 모두 정상적으로 동작하는지 확인하고 24시간 운용기준 호완료율 측정, 음성품질을 측정하여 이에 대한 시험결과를 소개한다.

  • PDF

Measurement and Analysis of Soil moisture Behavior in Unsaturated Zone on a Steep Hillslope (사면불포화조건에서의 토양수분 흐름거동의 측정과 분석)

  • Gwak, Yong Seok;Kim, Sang Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.471-471
    • /
    • 2015
  • 토양내의 수분흐름을 이해하는 것은 토양수분의 시공간적 분포변화와 유출기작을 규명하는데 매우 중요하다. 본 연구에서는 설마천유역의 작은 사면에서의 장력측정 시스템을 구축하여, 3차원의 흐름방향에 대해 잠재적 흐름구배를 평가하고자 하였다. 또한 흐름구배를 평가하기 위한 일반적 산술적 계산방법인 평균적 흐름구배와 측정시스템의 구조적 영향 및 흐름구배의 공간적 평가 기준을 고려한 계산방법론을 개발하여 비교 평하였다. 3차원의 흐름방향은 사면의 지표경사를 기준으로 x, y, z축을 기준으로 하여, 각 축 방향에 해당하는 흐름구배 값과 흐름방향을 각각 계산하였다. 그 결과, 강우사상에 따른 토양내의 장력변화는 매우 민감하게 변화하였으며, 이에 따른 각 흐름구배 값과 흐름방향의 반응이 빠르게 반응을 하였다. 특히, 습윤, 건조기간동안의 흐름구배의 발달 및 방향이 바뀌는 천이되는 상태인 흐름 굽힘 현상(flow Bending)을 확인하였다.

  • PDF

The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy (방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가)

  • Kim, Yeong Seon;Seo, Myung Deok;Lee, Wan Kyu;Kim, Ki Joon;Song, Jae Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.12-17
    • /
    • 2012
  • Purpose : The patient's clothes and sheet after radioiodine therapy must be disposed of by related regulation. That must be disposed of as radioactive wastes, but that is reusing after radioactivity decay by keeping for the certain period of time. In general, The minimum storage period calculate by standard of take radioactive substance out of radiation controlled area based on measured surface contamination level. But the measurements of surface contamination level are able to differ by measurement method. In this paper, I wish to calculate the minimum storage period of patient's clothes and sheet after radioiodine therapy by measure nuclide concentration offered by the regulation on self-disposal of radioactive wastes. Materials and Methods : The whole area of patient's clothes and sheet measured 31 patients(male:9 patients, female:22 patients), who had radioiodine therapy(3.7 GBq:13 patients, 5.55 GBq:16 patients, 7.4 GBq:2 patients) from july 2011 to march 2012. The minimum storage period is calculated by the regulation on self-disposal of radioactive waste(100 Bq/g) and standard of take radioactive substance out of radiation controlled area(4 kBq/m2) Results : The minimum storage period of pillow sheet, upper uniform, lower uniform by standard of take radioactive substance out of radiation controlled area were each 4.6 days, 63days, 78 days. The minimum storage period of pillow sheet, upper uniform, lower uniform by the regulation on self-disposal of radioactive waste were each 18.1 days, 43 days, 62 days. Conclusion : We can verify that patient's clothes and sheet after radioiodine therapy exists a great deal of radioactive contamination. The minimum storage period calculation of patient's clothes and sheet is better suited to applying nuclide concentration offered by the regulation on self-disposal of radioactive waste. I recommend, To keep for at least 2 months of the patient's clothes and sheet contaminated radioactivity, for prevent contamination and unnecessary radiation exposure.

  • PDF