• Title/Summary/Keyword: 측정값

Search Result 14,436, Processing Time 0.042 seconds

Assessment of Landscape Tree Vigor Using Cambial Electrical Resistance (형성층 전기저항을 이용한 조경용 수목 활력도 분석)

  • Hwang, Dong Kyu;Kim, Dong Yeob
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.302-306
    • /
    • 2016
  • There are various methods to evaluate tree vigor. Cambial electrical resistance represents tree vigor using the method of electrophysiological diagnosis. This study investigated the vigor of several tree species using Shigometer, and compared the differences among the species. The factors, such as foliation, trunk orientation and bark temperature, which affect electrical resistance were also investigated. The needle penetration into cambium was controlled to keep the depth consistent in order to minimize measurement error. Each of three trees were selected from Zelkova serrata, Ginkgo biloba, Metasequoia glyptostroboides, Pinus koraiensis, and Liriodendron tulipifera. The electrical resistances were measured at 60 and 120 cm height of the stem in 4 directions from March until May 2011. The soil conditions in surrounding areas and tree stress responses were also measured. The results were analyzed for the relationship between electrical resistance and the affecting factors. The electrical resistance showed a relatively higher level before foliation until mid-March. The values started to decline from April and recorded a minimal level on May 11. The changes of soil moisture, soil electric conductivity, and tree stress responses during the measurement period showed a similar trend to that of electrical resistance. The Pinus koraiensis, an evergreen conifer, showed few changes on the electrical resistance values during the measurement period. Zelkova serrata, Ginkgo biloba, and Metasequoia glyptostroboides showed the highest bark temperatures and lowest electrical resistances at their south-facing stem. Shigometer can provide measures simple to assess tree vigor in the fields, and to the management of trees.

LiF TLD in TLD Holder for In Vivo Dosimetry (생체 내 선량측정을 위한, TLD홀더에 넣은 LiF TLD)

  • Kim Sookil;Loh John J.K.;Min Byungnim
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.293-299
    • /
    • 2001
  • Prupose : LiF TLD has a problem to be used in vivo dosimetry because of the toxic property of LiF. The aim of this study is to develop new dosimeter with LiF TLD to be used in vivo dosimetry. Materials and methods : We designed and manufactured the teflon box(here after TLD holder) to put TLD in. The external size of TLD holder is $4\times4\times1\;mm^3$ To estimate the effect of TLD holder on TLD response for radiation, the linearity of TLD response to nominal dose were measured for TLD in TLD holder. Measurement were peformed in the 10 MV x-ray beam with LiF TLD using a solid water phantom at SSD of 100 cm. Percent Depth Dose (PDD) and Tissue-Maximum Ratio (TMR) with varying phantom thickness on TLD were measured to find the effect of TLD holder on the dose coefficient used for dose calculation in radiation therapy. Results : The linearity of response of TLD in TLD holder to the nominal dose was improved than TLD only used as dosimeter And in various measurement conditions, it makes a marginnal difference between TLD in TLD holder and TLD only in their responses. Conclusion : It was proven that the TLD in TLD holder as a new dosimetry could be used in vivo dosimetry.

  • PDF

Chlorophyll a/b Ratio as a Criterion for the Reliability of Absorbance Values Measured for the Determination of Chlorophyll Concentration (엽록소 농도 결정을 위하여 측정한 흡광도 값의 신뢰도 검정 지표로서 엽록소 a/b 비례치)

  • Wu, Guangxi;Lee, Choon-Hwan
    • Journal of Life Science
    • /
    • v.29 no.5
    • /
    • pp.509-513
    • /
    • 2019
  • The Beer-Lambert law states that absorbance is proportional to the concentration of a solute in a solution at a given wavelength. This linearity works for an ideal or a 'sufficiently diluted' solution, so this linearity is often used as a criterion for the fidelity of the absorbance value measured. In this study, we used a chlorophyll (Chl) solution, isolated from rice leaves with 80% acetone to test the use of the Chl a/b ratio as an additional criterion for checking the fidelity of measured values using four different absorption spectrophotometers: Cary4E, UV-1650PC, Versamax (a microplate reader), and NanoDrop 1,000(which can handle a $4{\mu}l$ aliquot). We used Chl solutions of varying concentrations from $0.2{\mu}g/ml$ to $200{\mu}g/ml$ to measure absorbance values at 645 nm and 663 nm and checked the linearity first. The results indicated that the range of Chl concentrations that we can rely on based on the linearity was similar to the range in which the calculated Chl concentrations based on the measured absorbance values agreed with the known concentrations. However, some border cases or cases with very low Chl concentrations inside the fidelity range of Chl concentrations did not agree with the criterion that the Chl a/b ratio should not change after dilution of the Chl in the solution. These results suggest that the Chl a/b ratio is a better criterion for the reliability of the absorbance values measured for the determination of chlorophyll concentration than the criterion based on the linearity suggested by the Beer-Lambert law.

Mixed Micellar Properties Dodecyldimethyl(3-sulfopropyl)ammonium Hydroxide with Other Surfactants (Dodecyldimethyl(3-sulfopropyl)ammonium Hydroxide와 다른 계면활성제와의 혼합미셀화에 관한 연구)

  • Lee, Nam-Min;Lee, Byung-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.602-611
    • /
    • 2014
  • The critical micelle concentration (CMC) of the zwitterionic surfactant of dodecyldimethyl(3-sulfopropyl)ammonium hydroxide(LSB, $CH_3(CH_2)_{11}N^+(CH_3)_2(CH_2)_3SO{_3}^-$) and LSB/Tween-20, LSB/Tween-40, LSB/Tween-80 and LSB/DTAB, LSB/TTAB, LSB/CTAB mixed surfactant systems were determined by using the UV/Vis absorbance method from 284 K to 312 K. And the effects of temperature on the micellization have been measured for the thermodynamic study. The results show that the measured values of gibbs free energy are all negative in the whole measured. The values of enthalpy are positive Tween-20, And negative other surfactants. but the values of entropy are positive in the whole measured temperature region. The results show that all of the thermodynamic parameters are dependent on temperature and alkyl-group's length.

Tracking Filter Dealing with Nonlinear Inherence as a System Input (비선형 특성을 시스템 입력으로 처리하는 추적 필터)

  • Shin, Sang-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.774-781
    • /
    • 2014
  • The radar measurements are composed of range, Doppler and angles which are expressed as polar-coordinate components. An approach to match the measurements with the states of target dynamics which are modeled in cartesian coordinates is to use the pseudo-measurements or the extended Kalman filter in order to solve the mismatching problem. Another approach is that the states of dynamics are modeled in polar coordinates and measurement equation is linear. However, this approach bears that we have to deal with a time-varying dynamics. In this study, it is proposed that the states of dynamics are expressed as polar-coordinate component and the system matrix of the dynamic equation is modeled as a time-invariant. Nonlinear terms that appear due to the proposed modeling are regarded as a system input. The results of a series of simulation runs indicate that the tracking filter that uses the proposed modeling is viable from the fact that the Doppler measurement is easy to be augmented in the measurement equation.

Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD (TLD를 이용한 X-선 수중 흡수선량 측정 및 해석)

  • Oh, Jang-Jin;Jun, Jae-Shik;Hah, Suck-Ho;Kim, Wuon-Shik;Hwang, Sun-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.21-28
    • /
    • 1988
  • Absorbed dose in water was analyzed by Burlin's general cavity theory for medium X-ray energy region (HVL : 0.29, 0.84, 1.60, 2.62mm Cu) using LiF : PTFE TL dosimeter(0.4 mm ${\times}\;{\phi}$ 12.5mm, hot-pressed LiF TLD-700) which was enclosed in lucite capsule. The absorbed dose rate at 5cm depth in water phantom was determined with measurement error of ${\pm}5%$. This result was compared to that of the ionization method, indirectly absolute measurement method, of which measurement error of ${\pm}2%$. The difference between these two results lies within measurement error of LiF : PTFE method. Therefore, the absorbed dose in water obtained by LiF: PTFE is reliable, and this result suggests the base to estimate dose-equivalent for medium X-rays.

  • PDF

Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향)

  • 이복희;엄주홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • In this paper, the effects of the positions of the potential and current probes on the measurements of the ground resistance and potential gradients with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and ground resistance of the measuring probes. The ground resistance is calculated by applying the 61.8% and rule in the fall-of-potential method, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring probes in on-site test might not be arranged on the straight line with adequate distance because there are building, road block, construction and other establishments. Provided that the grounding electrode to be measured and the measuring probes ar out of position on the straight line or have inadequate distance, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. Measurements were focused on the grounding electrode system made by the ground rods of 2.4m long. It was found that the suitable separation between the grounding electrode to be measured and the current probe is more than 5 times of the length of the grounding electrode to be measured.

  • PDF

Dynamic Behavior Character of Vessel Using DGPS and Motion Sensor (DGPS와 Motion Sensor를 이용한 선박 동적 거동특성)

  • Choi, Chul-Eung;Kim, Youn-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.4 s.31
    • /
    • pp.35-43
    • /
    • 2004
  • Multibeam Echosounder system is the latest technology of a hydrographic survey utilized in producing an electronic nautical chart, obtaining a DEM with high precision, making a moving image by Swath surveying a wide area. As a fundamental study for improving the precision of MBES, we compared and analyzed measurements of DGPS and Motion sensor, and studied for the dynamic characteristics of vessel's movements. DGPS was installed in front and in the rear and on both side or the vessel and surveyed. The receiving precision of surveyed GPS results was obtained to the satisfactory extent that was possible to valuate the accuracy of Motion sensor as 0.0016$^{\circ}$ of the roll value and 0.0009$^{\circ}$ of the pitch value. The relationship between the values of heading, pitch, and roll in Motion sensor and the data of DGPS was proportional correlation. In addition, it is considered that deviations by elements like rapid turning and vibration of the vessel will be occurred, although the correlation of each deviation according to each amount or change is proportional. It is suitable that GPS installs in the central line of the vessel that is less affected than other places by waving because the amount of change in the tide level obtained from GPS survey and the value of heave are similar with the values taken by Motion sensor, and the velocity of GPS is different from installed places. The accuracy of the final result from MBES could be affected by the values of gyro and Motion sensor inputted to MBES processor because there were intervals of 15s and 13s of receiving time in gyro and Motion sensor respectively compared with the real-time measurements of DGPS.

  • PDF

A Development of the Obstacle Error Correction Algorithm using PSD And Electronic Compass (PSD와 전자나침반을 이용한 장애물 에러 보정 알고리즘 개발)

  • Lim, Shin-Taek;Chong, Kil-Do;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.433-434
    • /
    • 2008
  • 이 논문은 실내에서 로봇의 주행 시 생기는 오차를 수정하는 것이다. 실내에 있는 장애물(문턱)을 넘을 경우 슬립에 의하여 주행거리와 실제거리의 오차가 생기고 또한 헤드 앵글 값이 변화함에 따라서 차후 엄청난 주행 오차를 발생시키게 된다. 그에 따라 PSD 센서를 이용하여 장애물을 감지하고 감지 후 장애물을 넘을 수 있도록 모터를 제어한다. 또한 PSD를 이용하여 장애물의 크기를 계산한 후 로봇이 장애물을 넘는 동안에 엔코더 값을 받아 들여서 장애물을 넘는 동안에 로봇이 실제 이동한 거리를 측정한다. 그리고 장애물을 넘은 후에 PSD로 계산한 장애물의 크기 값과 엔코더에서 받아들인 값을 비교하여 거리오차를 수정한다. 또한 전자컴퍼스를 이용하여 장애물을 넘기 전에 로봇의 헤드 앵글 값을 구하고, 장애물을 넘은 후에 로봇의 헤드 앵글 값을 구하여 두 개의 값을 비교한다. 두 개의 값의 차이를 측정하여 수정함으로써 헤드 앵글을 오차를 수정할 수 있다.

  • PDF

Evaluation of the Pressure of the Tongue, Lips, and Cheeks in Patients with Myofunctional Therapy and Appliance (근 기능 훈련 및 장치 치료를 시행한 환자들의 혀, 입술, 볼의 최대 압력 비교)

  • Minah Sung;Myeongkwan Jih;Nanyoung Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.13-23
    • /
    • 2023
  • The purpose of this study was to compare the values of tongue pressure (TP), lip closing pressure (LCP), right buccal pressure (RBP), and left buccal pressure (LBP) and check the intraoral muscle imbalance and observe the changed values according to the myofunctional therapy (MFT) period. The MFT with a prefabricated appliance was performed on patients with certain muscular dysfunctions due to oral habits. And the improvement of perioral muscles was evaluated using a balloon-based pressure measurement. The group consisted of 21 patients with oral habits such as chronic mouth breathing, finger sucking, lip sucking, tongue thrusting, and atypical swallowing habits. When comparing the two groups before treatment, there was a significant difference in TP and LCP values. The TP increased the most in the first month since the start of myofunctional therapy, and the LCP increased the most between 3 and 6 months after treatment began. The values of TP, LCP, RBP, and LBP in the control group measured before treatment were very similar to the results of the experimental group 6 months after the myofunctional therapy. When the MFT was steadily performed, it was possible to observe a noticeable increase in the tongue and lip closing pressure. At least 6 months of myofunctional therapy is recommended for patients with intraoral muscle imbalance due to oral habits.