• 제목/요약/키워드: 측방향

검색결과 87건 처리시간 0.036초

Simultaneous Multiple Transmit Focusing Method with Orthogonal Chirp Signal for Ultrasound Imaging System (초음파 영상 장치에서 직교 쳐프 신호를 이용한 동시 다중 송신집속 기법)

  • 정영관;송태경
    • Journal of Biomedical Engineering Research
    • /
    • 제23권1호
    • /
    • pp.49-60
    • /
    • 2002
  • Receive dynamic focusing with an array transducer can provide near optimum resolution only in the vicinity of transmit focal depth. A customary method to increase the depth of field is to combine several beams with different focal depths, with an accompanying decrease in the frame rate. In this Paper. we Present a simultaneous multiple transmit focusing method in which chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in a sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels. and the crossorelation function of any Pair of the signals has values smaller than the sidelobe levels of each autocorrelation function. This means that each chirp signal can be separated from the combined received signals and compressed into a short pulse. which is then individually focused on a separate receive beamformer. Next. the individually focused beams are combined to form a frame of image. Theoretically, any two chirp signals defined over two nonoverlapped frequency bands are mutually orthogonal In the present work. however, a tractional overlap of adjacent frequency bands is permitted to design more chirp signals within a given transducer bandwidth. The elevation of the rosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals We also observe that the Proposed method provides better images when the low frequency chirp is focused at a near Point and the high frequency chirp at a far point along the depth. better lateral resolution is obtained at the far field with reasonable SNR due to the SNR gain in Pulse compression Imaging .

Behaviors of Soft Bangkok Clay behind Diaphragm Wall Under Unloading Compression Triaxial Test (삼축압축 하에서 지중연속벽 주변 방콕 연약 점토의 거동)

  • Le, Nghia Trong;Teparaksa, Wanchai;Mitachi, Toshiyuki;Kawaguchi, Takayuki
    • Journal of the Korean Geotechnical Society
    • /
    • 제23권9호
    • /
    • pp.5-16
    • /
    • 2007
  • The simple linear elastic-perfectly plastic model with soil parameters $s_u,\;E_u$ and n of undrained condition is usually applied to predict the displacement of a constructed diaphragm wall(DW) on soft soils during excavation. However, the application of this soil model for finite element analysis could not interpret the continued increment of the lateral displacement of the DW for the large and deep excavation area both during the elapsed time without activity of excavation and after finishing excavation. To study the characteristic behaviors of soil behind the DW during the periods without excavation, a series of tests on soft Bangkok clay samples are simulated in the same manner as stress condition of soil elements happening behind diaphragm wall by triaxial tests. Three kinds of triaxial tests are carried out in this research: $K_0$ consolidated undrained compression($CK_0U_C$) and $K_0$ consolidated drained/undrained unloading compression with periodic decrement of horizontal pressure($CK_0DUC$ and $CK_0UUC$). The study shows that the shear strength of series $CK_0DUC$ tests is equal to the residual strength of $CK_0UC$ tests. The Young's modulus determined at each decrement step of the horizontal pressure of soil specimen on $CK_0DUC$ tests decreases with increase in the deviator stress. In addition, the slope of Critical State Line of both $CK_0UC$ and $CK_0DUC$ tests is equal. Moreover, the axial and radial strain rates of each decrement of horizontal pressure step of $CK_0DUC$ tests are established with the function of time, a slope of critical state line and a ratio of deviator and mean effective stress. This study shows that the results of the unloading compression triaxial tests can be used to predict the diaphragm wall deflection during excavation.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • 제17권6호
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

A Study on Radiation Dose for General Radiography Examination at First Medical Institution (Around the Radiology Clinic of National Capital Region) (일차 의료기관에서 일반촬영 검사의 피폭선량 연구 (수도권 영상의학과를 중심으로))

  • Hwang, Su-Lyun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • 제5권5호
    • /
    • pp.245-253
    • /
    • 2011
  • The hazard level will be increased with the augmentation of the dose received by patients. Therefore, patients radiation dose have been analyzed by this study for the radiology clinics located at Seoul and Gyeongin area from August 2009 to September 2010. In the case of the front and rear directional inspection of skull, patient radiation dose was turned out to be 1.75mGy for radiology clinic, 3.00mGy for UK, 3.00mGy for Japan, and 5.00mGy for Germany, therefore, radiology clinic was the lowest. In the case of lateral directional inspection of skull, patient radiation dose was turned out to be 1.49mGy for radiology clinic, 1.50mGy for 3rd medical institution, therefore, radiology clinic was measured lower, and it was lower than 3.00mGy which is the recommended dose of IAEA. In order to reduce medical exposure of patient, optimization of efficient protection of radiation and reduction of medical radiation exposure are thought to be required by observing recommendation of international organization based on the result of this study.

The Role of Glial Cells in Regenerative Responses of the Injured Corticospinal Tract Axons in Rats Treated with Cindii Rhizoma (흰쥐의 척수손상 후 천궁처리에 의한 피질척수로 축삭재생 반응시 Glial cells의 역할)

  • Han, Yeong-Su;Oh, Min-Seok
    • Journal of Korean Medicine Rehabilitation
    • /
    • 제18권3호
    • /
    • pp.19-39
    • /
    • 2008
  • Objectives : It has been reported that CG was effective in decreasing injury to neural tissues. To investigate neural responses in the injured spinal cord, an extract of CG was examined to determine its effect on neural responses in the injured spinal cords of rats. Methods : After CG treatment was applied to the spinal cord of rats given a contusion injury, the re-growth responses of injured neural tissues and corticospinal tract axons was observed by measuring the number of GAP-43, Cdc2, and phospho-Erk1/2 proteins, CST axons, GFAP-stained astrocytes, and Glial scarring in the injured spinal cord. Results : Levels of GAP-43, Cdc2, and phospho-Erk1/2 proteins were found to have increased in the injured spinal cord region. The number of GFAP-stained astrocytes also increased within and around the injury cavity. Glial scarring, which was identified by CSPG immunofluorescence staining, was reduced by CG treatment. Anterograde tracing by Dil dye showed that the elongation of the CST axons in the dorso-medial white matter area was almost completely prevented at the injury site. Collateral sprouting was observed in the spinal cord rostrally close to the injury site, and CG treatment further increased axonal arborization in the corresponding region. In vivo migration of CST axons and astrocytes using an implanted polymer tube system showed more of an increase in enhanced migration of axons and astrocytes in CG-treated group compared to the injury control group. Conclusions : These results suggest that CG activated neural responses - including astrocyte migration - and promotes axonal regenerative activity in the injured spinal cord area.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • 제17권1호
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

A Nested Cauldron Structure in the Tertiary Miocene Eoil Basin, Southeastern Korea (한반도 동남부 제3기 마이오세 어일분지내 둥지형 화산함몰구조)

  • Son, Moon;Kim, In-Soo;Ock, Soo-Seok
    • The Journal of the Petrological Society of Korea
    • /
    • 제10권2호
    • /
    • pp.121-131
    • /
    • 2001
  • The combination of geological, structural and satellite image studies is used to make an examination of the Miocene eruptive type in the Eoil Basin, SE Korea. The basin subsided by the NW-SE extension due to NNW dextral shearing during the East Sea opening. Based on geological structures as well as lithofacies and ages of the basin-fills, it is divided into the NE subbasin and the SW subbasin which were abundantly filled with basaltic volcanics and marine sediments without volcanic materials, respectively: Syndeposional synclines and anticlines are characteristically developed in the NE subbasin, which amplitudes decrease away from the adjacent normal faults to make them into a homoclinal structure. The thicker lavas as well as the younger agglomerates and lacustrine sediments, which show circular distributions, are distributed around the axial zones of major synclines. The satellite image shows four remarkable circular structures within the NE subbasin. They are located adjacent to and along the normal faults, and they are laid almost exactly on the axial zones of the synclines as well as on the distribution area of the agglomerates and lacustrine sediments. These facts indicate that the basaltic lava effusion were conducted by the normal faults like a kind of fissure-eruption and its activity was more predominant at the sites in where the synclines are developed. More active effusion of lava became a reason for deeper subsidence to make differential subsidence and syndepositional folding adjacent to and along the normal faults. Hence, we suggest that a nested cauldron structure was formed in the NE subbasin of the Eoil Basin, and that the volcanism made the subbasin to be a lava pond and controlled the process of filling and sedimentation in the subbasin.

  • PDF