• Title/Summary/Keyword: 측두골

Search Result 101, Processing Time 0.024 seconds

Proposal of Magnetic Coupling Type Implantable Middle Ear Hearing Aid (자기결합방식의 이식형 인공중이의 제안)

  • 정영숙;윤영호;박재훈;송병섭;이승하;김명남;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.487-495
    • /
    • 1998
  • In this paper, a new type of implantable middle ear hearing aid, which consists of external loop coil, a small magnet and a simple external device, is proposed. The internal device of proposed type consists of only a small magnet and the external device does not need to be positioned behind the ear or in the ear canal. The proposed type is excellent in cosmetic sides and very convenient to use, because the external device can be hidden in upper garment and collar of clothes. Also, purposely this type doesn't need to be small on the size of battery, which means it has longer battery life. Therefore, the battery is not necessary to be charged frequently. It also can solve the difficulty of gap calibration at surgical operation which conventional Implantable middle. Therefore, the battery is not necessary to be charged frequently. It also can solve the difficulty of gap calibration at surgical operation which conventional implantable middle ear hearing aid has. We investigate the performance of proposed implantable middle ear bearing aid and we analyze that proposed type is appropriate for mild and severe hearing impaired person and the result of experiment showed the accuracy of our analysis. For the validation of our analysis we used the temporal bone at the experiment and confirm that ossicles can be vibrated when the proposed system In startled in the body.

  • PDF

Finite Element Analysis of Sound Transfer Characteristics for Middle Ear (유한요소 모델을 이용한 중이의 소리전달 특성 해석)

  • Gal, Young-Min;Baek, Moo-Jin;Lee, Doo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1563-1571
    • /
    • 2011
  • In this study, we developed a finite element model of the human middle ear has been developed to calculate itsfor sound transfer characteristics calculation. We usedThe geometric data forof ossicles, obtained byfrom micro-CT scanning, was used in order to develop the middle- ear FE model. A right- side temporal bone of a Korean cadaver was used for the micro-CT scanning. The developed FE model includes three ossicles, the tympanic membrane, ligaments, and muscles. We calculated theA sound transfer function from the tympanic membrane to the stapes footplate was calculated. The sound transfer function calculated vias of the FE model shows good agreement with measured responses over the 10- kHz frequency band. To measureidentify the sensitivityies of the middle- ear function due to material property variation, we studied several parameters studies have been fulfilled using the middle ear FE model. TAs a result the stiffness property of the incudostapedial joint had the greatest influence onwas the most influential to the middle- ear sound transfer function among the parameters.

Design of Implantable Middle Ear Hearing Aids Using an Electromagnetic Transducer (전자 트랜스듀서 방식에 의한 청각보조용 이식형 인공중이 시스템 설계)

  • Cho, Jin-Ho;Song, Byung-Seop;Kim, Myoung-Nam;Won, Chul-Ho;Park, Se-Kwang;Lee, Sang-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.466-475
    • /
    • 1997
  • In this paper, an implantable middle ear hearing aids using an electromagnetic transducer which consists of a tiny coil and a magnet is designed, and objective design method to implement a vibrator of the electromagnetic type transducer is proposed. Sound characteristic of the electromagnetic type vibrator is excellent but power transfer rate is lower than that of a ceramic type. To improve power transfer efficiency of system, external and inner part of a middle ear system is designed using FM transmission method. We implemented an experimental set of the designed transducer, inner part, and outer part. Then, we measured vibration characteristics of a metal strip and a temporal bone of a dead body. As the results, we confirmed the advantage of FM method and showed that designed transducer could effectively transmit vibration of amplified input sound pressure to ossicle.

  • PDF

The Design of Temporal Bone Type Implantable Microphone for Reduction of the Vibrational Noise due to Masticatory Movement (저작운동으로 인한 진동 잡음 신호의 경감을 위한 측두골 이식형 마이크로폰의 설계)

  • Woo, Seong-Tak;Jung, Eui-Sung;Lim, Hyung-Gyu;Lee, Yun-Jung;Seong, Ki-Woong;Lee, Jyung-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.144-150
    • /
    • 2012
  • A microphone for fully implantable hearing device was generally implanted under the skin of the temporal bone. So, the implanted microphone's characteristics can be affected by the accompanying noise due to masticatory movement. In this paper, the implantable microphone with 2-channels structure was designed for reduction of the generated noise signal by masticatory movement. And an experimental model for generation of the noise by masticatory movement was developed with considering the characteristics of human temporal bone and skin. Using the model, the speech signal by a speaker and the artificial noise by a vibrator were supplied simultaneously into the experimental model, the electrical signals were measured at the proposed microphone. The collected signals were processed using a general adaptive filter with least mean square(LMS) algorithm. To confirm performance of the proposed methods, the correlation coefficient and the signal to noise ratio(SNR) before and after the signal processing were calculated. Finally, the results were compared each other.

Inferior Orbital Wall Reconstruction with Vascularized Partial Thickness Calvarial Bone Flap in Three Cases of Maxillary Tumor (혈행화된 부분층 두개골피판을 이용한 상악골 종양 적출 환자에서의 안와하벽 재건술 증례)

  • Shin, Sang Ho;Lee, Yoon Jung;Kim, Jun Sik;Kim, Nam Gyun;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Purpose: Inevitably, Maxillary structural defect follows maxillary cancer extirpation. Maxillary reconstruction is over every surgeon's head. Every physician tried to overcome limited donor site of craniofacial defect. We considered to suggest optimal method of inferior orbital wall defect in functional point as well as esthetic point. Methods: We performed wide excision of maxilla and vascularized partial thickness calvarial bone flap to reconstruct the defect from cancer extirpation in three cases. We select ipsilateral superficial temporal artery, vein and outer cortex of parietal bone flap as donor. And we applied bone flap as inferior orbital wall structure. The bony surface was wrapped with fascia to prevent direct contact between orbital contents and rough bony flap surface. Computed tomography image was checked during follolw up period. Results: We can observe these patients for over two years. In all three cases, We can get fair inferior orbital wall structure. Even though they got radiation therapy, there was no limitation of extraocular movements, no diplopia. no enophthalmos. Also there was minimal donor site morbidity. Conclusion: We suggest vascularized calvarial bone flap is practically excellent strategy for inferior orbital wall reconstruction.

Bone Conduction Loss in Chronic Otitis Media (만성중이염에서의 골도장애)

  • 김종선;김시영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.3.2-3
    • /
    • 1979
  • Bone conduction loss is one of the most common complication in chronic otitis media, and is mostly high frequency loss. Of 233 tympanomastoidectomy ears, 187 ears were considered eligible for this study. A histopathological change was examined in the natural otitis media of guinea pigs. It is our intention to analyze the pattern of bone conduction loss in chronic otitis media, and to correlate this findings with clinical and pathological changes in human and animal otitis media. l) In unilateral cases, a significant difference in bone conduction threshold was observed between normal and diseased ears, and between each frequency with significant interaction between 2KHz and 4KHz (p 0.01). 2) Using one way analysis of variance, mean bone conduction was compared with the duration of disease. We observed a significant difference (p 0.05) between each group of duration, except between 11-15 and 15-20 years group. 3) A comparison of bone conduction between stapes loss group and intact stapes group revealed significant t ratio (p 0.01) at each frequency. The effect of stapes loss on each frequency was evaluated, using one way analysis of variance. there were significant difference(p 0.05) between 250Hz and 500Hz. and between 2KHz and 4KHz. 4) A comparison of bone conduction between round window obliteration and nonobliteration group revealed significant t ratio (p 0.01) at each frequency. Using one way analysis of variance. the effect of round window obliteration was evaluated in each frequency. We observed significant difference (p 0.05) between 250Hz and 500Hz. and between 2KHz and 4KHz. 5) A comparison of bone conduction between cholesteatoma and non -cholesteatoma group revealed significant t ratio (p 0.01) only in 2KHz and 4KHz. No significant differency was observed in mean bone conduction. 6) In a histopathological study of natural otitis media in guinea pig, we observed inflammatory infiltration of the round window membrane, serofibrinous precipitate in the scala tympani, and degeneration of the organ of Corti most significant near the basal turn. These changes would explain high tone bone conduction loss in the process of chronic otitis media.

  • PDF

USEFULNESS OF MIDFACIAL DEGLOVING APPROACH IN ORAL & MAXILLOFACIAL REGION (구강악안면외과 영역에서의 MIDFACIAL DEGLOVING APPROACH의 유용성)

  • Cha, In-Ho;Yoon, Hyun-Joong;Lee, Eui-Wung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.214-216
    • /
    • 1998
  • In the treatment of maxillary lesion including a maxillary sinuses, most of oral and maxillofacial surgeons have used the vestibular incision or the Weber-Fergusson incision. However, the vestibular incision has disadvantage which it provides a rather limited exposure and the Weber-Fergusson incision leaves visible scar in the midface. Furthermore, because the scar is confined on unilateral side only, the technique is hesitated to apply especially in children, younger patients and women. Since Casson first introduced midfacial degloving technique, this approach has been used frequently to treat the lesion on nasal cavity, nasopharynx, skull base and paranasal sinuses by ENT surgeons. But, we think this technique can be used usefully in oral and maxillofacial regions. So, we experienced favorable results which it provided a proper exposure, no visible facial scar and it could be used on bilateral midfacial lesions.

  • PDF

Case report: Treatment of Facial Nerve Palsy Following Bilateral Sagittal Split Ramus Osteotomy (증례보고 : 양측 하악지 시상골 절단술 후 발생한 안면신경 마비)

  • Ryu, Ji-Won
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.3
    • /
    • pp.255-260
    • /
    • 2013
  • Bilateral sagittal split ramus osteotomy(BSSRO) of the mandible is an essential and commonly used procedure to correct dentofacial deformities and malocclusion. The possible complications associated with BSSRO include inferior alveolar nerve injury, bleeding, temporomandibular disorder, unfavorable fractures, and clinical relapse. The incidence of facial nerve palsy after orthognathic surgery recently reported is 0.1%. The probable etiologies have included facial nerve compression, complete or incomplete nerve transection, nerve traction, and nerve ischemia from anesthetic injection. Postoperative facial palsy is one of the most serious complications because it reduces the quality of life and significantly reduces social interaction. The case of a 24-year-old patient who underwent bilateral sagittal split ramus osteotomy is described. The medical records and postoperative photographs were reviewed in detail to collect information on the clinical course, treatment, and outcomes.

Complete mouth rehabilitation, using jaw motion tracking and double scan technique in a patient with osteoarthrosis: a case report (골관절증 환자에서 하악 운동 추적 장치와 이중 스캔 기법을 활용한 완전 구강 회복 증례)

  • Seo-Kyung Jeong;Jai-Young Koak;Seong-Joo Heo;Seong-Kyun Kim;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.82-94
    • /
    • 2024
  • This is a case report of complete mouth rehabilitation in a patient with generalized attrition and loss of posterior support. After analyzing the condition of the temporomandibular joint, multiple implants were placed to restore collapsed occlusion. Fixture/abutment level intraoral scanning was done instead of using conventional impression materials which entail multiple bite registration for cross-mounting. A 'jaw motion tracking'device, 'digital face-bow transfer', and 'double scan technique' which enables duplicating temporary restoration to definitive restoration were used to fabricate definitive prostheses. By using various digital techniques, complete mouth rehabilitation was done with minimal chair time in a patient with unstable occlusion.

Comparison of planar scintigraphy and bone SPECT with clinical findings and other imaging modalities in temporomandibular disorder patients (측두하악관절장애 환자에서의 평면 골 스캔 및 Bone SPECT 소견과 임상적 및 영상학적 소견과의 비교)

  • Jeong Hee-Jeong;Cho Bong-Hae;Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.34 no.2
    • /
    • pp.91-97
    • /
    • 2004
  • Purpose : This study was performed to evaluate the diagnostic value of both planar and SPECT imagings by comparing the results with the clinical and other imaging modalities findings. Materials and Methods: A total of 578 joints with TMJ complaints were examined using planar scintigraphy and SPECT. The planar scintigraphy and SPECT findings were analyzed and compared to the clinical findings of pain, clicking, crepitus and limitation of mouth opening. Moreover we compared the accuracy of the planar scintigraphy and SPECT methods with the one of the panoramic, transcranial, tomographic and MR imaging methods. Results: The planar scintigraphy and SPECT methods showed a high sensitivity of 0.76-0.84 and low specificity of 0.25-0.45 toward the clinical findings: pain, clicking, crepitus and mouth opening restriction. Simple radionuclide uptake ratio was high in each group of patients with pain, crepitus, limitation of mouth opening (p < 0.05) complaints, in each group with positive bone changes on panoramic, transcranial or tomographic images, and in disc displaced group. Conclusion: Although both planar and SPECT imagings have limited specificity, these techniques are sensitive for detection of internal derangement of the TMJ.

  • PDF