• Title/Summary/Keyword: 충진

Search Result 1,587, Processing Time 0.029 seconds

The Flexural Behavior of a Square Concrete Filled Carbon Tube Columns under the Constant Axial Force with Reversed Cyclic Lateral Load (축하중과 반복 횡하중을 받는 콘크리트 충진 각형 탄소섬유 튜브 기둥의 휨거동특성)

  • Kim, Hee-Cheul;Hong, Won-Kee;Lee, Hyun-Ju
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • The purpose of this study is to investigate the flexural behavior of square concrete filled carbon tube (CFCT) columns subjected to constant axial load with the cyclic lateral load. Two parameters, wnding angle and thickness of tube, were chosen to evaluate the flexural capacity and behavior of rectangular CFCT columns. Selected two parameters were considered simultaneously in order to evaluate the flexural behavior of a rectangular CFCT columns more precisely. Flexural strength, deformation capacity, ductility and energy dissipation capacity of rectangular CFCT columns were evaluated by calculating the area of load-displacement envelope curves and load-dispalcement hysteresis curves obtained from experiment. Also, the ductile capacity obtained from experiment was compared to that of reinforced masonry wall for the comparison of existing structural element.

Strucural, Thermal, Electrical Characteristics of Epoxy-Nanocomposites according to Dispersion Agent Treatment (분산제 처리에 따른 에폭시-나노콤포지트의 구조적, 열적, 전기적 특성)

  • Park, Jae-Jun;Lee, Sang-Hyup;Kim, Jae-Bong;Lee, Sung-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.256-256
    • /
    • 2009
  • 에폭시수지에 층상실리케이트 나노입자를 충진함량별로 충진시킨 나노콤포지트를 제조하여 충진함량의 변화와 분산제 첨가를 통하여 분산제효과를 조사하였다, 충진함량의 변화는 1, 3, 5, 7, 9wt%과 분산제 변화를 05, 1.5, 2.5wt%로 구조적, 열적, 전기적 특성을 조사하였다. 분산처리는 초음파 기법을 적용하여 분산하였다. 구조적 특성으로 X-RD조사한 결과 0.5wt%분산제처리를 한 경우 완전한 박리를 가져오지 못하였고, 부분적인 박리를 가져왔다. 이는 분산제 처리량이 나노입자 표면정체를 제어할수 없기 때문으로 사료된다. 분산제 1.5wt%를 첨가한경우로 충진함량별 X-RD특성은 1wt%는 완전한 박리를 나타내었고 함량의 증가에 따라 박리정도가 약간 낮아지는 경우를 알 수 있다. 이런 경우 전기적특성중 단시간 절연파괴특성에서 나타내고 있다. 충진함량이 낮을수록 스케일파라미터의 값이 높고, 함량이 증가할수록 낮아지는 경우이다. 이는 분산정도에따라 절연파괴강도에 영향을 주고 있음을 알 수 있다. 열적특성에서 유리천이온도는 1,3,5wt%에서는 증가하는 결과를 더욱 충진함량이 증가하면 오히려 감소되는 특성을 나타내고 있다. 결국은 분산정도에따라 전기적 특성 및 열적특성이 크게 변화되는 특성을 나타내었다.

  • PDF

The Flexural Behavior of a Circular Concrete Filled Carbon Tube Columns under the Constant Axial Force with Reversed Cyclic Lateral Load (축하중과 반복 횡하중을 받는 콘크리트 충진 원형 탄소섬유 튜브 기둥의 휨거동특성)

  • Hong, Won-Kee;Kim, Hee-Cheul;Chung, Jin-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.13-22
    • /
    • 2004
  • The purpose of this study is to investigate the flexural behavior of circular concrete filled carbon tube(CFCT) columns subjected to constant axial load with the cyclic lateral load. Six numbers of composite columns were tested. Two parameters, winding angle and thickness of tube, were chosen to evaluate the flexural capacity and behavior of CFCT columns. Selected two parameters were considered simultaneously in order to evaluate the flexural behavior of CFCT columns more precisely. Flexural strength, deformation capacity, ductility and energy dissipation capacity of CFCT columns were evaluated by calculating the area of load-displacement envelop curves and load-displacement hysteresis curves obtained from experiment. Also, the ductile capacity obtained from experiment were compared to that of reinforced masonry wall for the comparison of existing structural element.

Experimental Investigation of Characteristics Change by Kerf-Fill Material between Arrayed Elements of a Piezoelectric Transducer (압전 배열 트랜스듀서의 진동 요소간 kerf 충진 매질에 따른 특성변화의 실험적 고찰)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.215-220
    • /
    • 2008
  • The kerfs between arrayed piezoelectric elements in a medical ultrasonic transducer or a piezoelectric composite transducer are generally filled by polymeric materials. The boundary condition of the elements for lateral mode vibration is changed according to the kerf-filling materials, so that the resonance frequency for longitudinal mode of the transducer is also varied. In this study, to investigate the resonance frequency variation for an arrayed transducer experimentally, the piezoelectric vibration elements of $14mm{\times}0.22mm{\times}0.44mm$ were fabricated and those were linearly arrayed. And, the resonance frequencies were measured for three cases of kerf-filling condition, non-filling and two different kinds of epoxy filling. Conclusively, it is confirmed that the resonant frequency variation shows the similar tendency with the theoretical one for the longitudinal mode.

Effects of Leukocyte Depleted Priming Solution on Cardiopulmonary Edema by Extracorporeal Circulation (백혈구제거 혈액성 충진액이 체외순환 후 심폐부종에 미치는 영향)

  • Kim, Si-Hoon;Kim, Young-Du;Jin, Ung;Jo, Keon-Hyun
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.704-710
    • /
    • 2001
  • Background: Extracorporeal circulation using pump-oxygenator is an inevitable process to keep vital sign during cardiac arrest for open heart surgery. However, the diversion of blood through nonendothelialized channels appears to stimulate inflammatory response, and leukocyte activation may lead to cardiopulmonary edema. Our study evaluated the effect of leukocyte-induced cardiopulmonary edema using three different pump-oxygenator priming solutions; non-hemic crystalloid solution ; leukocyte-depleted homologous blood; non leukocyte-depleted homologous blood in priming solutions. Material and Method: Each different priming solution was used on five dogs, and the effect of leukocyte-induced cardiopulmonary edema during cardiopulmonary bypass(CPB) was evaluated. For each dog after 2 hours of exracorporeal circulation and another 4 hours of post-pump period, the dog was sacrificed and its heart and lung tissues were obtained for measuring Wet/Dry ratio. Arterial $O_2$partial pressure(PaO$_2$) and $CO_2$partial pressure(Pa$CO_2$) were checked. For the evaluation of ventilatory function, $CO_2$partial pressure difference between arterial blood (Pa$CO_2$) and exhaled air(Et$CO_2$) was measured. Result: 1. No significant difference was seen in arterial PaO$_2$and Pa$CO_2$among groups. 2. Ventilatory function evaluated by Pa$CO_2$and Et$CO_2$showed no significant difference between non-hemic and blood-mixed priming solution (P<0.05). 3. Cardiac and lung Wet/Dry ratios were remarkedly lower in the leukocyte-depleted group. There was no significant difference between the non-hemic and blood-mixed groups. Conclusion: Based upon this result, we concluded that the leukocyte depletion from homologous blood of CPB priming solution has a beneficial effect in reducing cardiopulmonary edema compared with non leukocyte-depleted or crystalloid priming solutions.

  • PDF

The Effect on Treatment Performance of Fiber Filter Under Various Packing-Density and Filtration Velocity (충진밀도와 여과속도가 섬유사 여과기의 처리 성능에 미치는 영향)

  • Im, Jeong-Hoon;Kim, Hyo-Kwan;Lee, Jung-June;Moon, Tae-Sup;Jeong, Min-Ki;Woo, Hae-Jin;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.216-222
    • /
    • 2006
  • A flexile fiber filter developed in Korea was operated to evaluate the effect of packing density and filtration velocity on particle removal. The pilot-scale fiber filter with 40 cm of diameter and 2 m of height was packed with polyamide fibers of which mean diameter was approximately 0.93 mm. While the filtration velocity was maintained at 325 m/hr, the particle removal efficiency was compared with various of packing density from $70kg/m^3\;to\;100kg/m^3$. On the contrary, when the packing density was maintained at $70kg/m^3$, the particle removal efficiency was examined with various filtration velocity from 65 m/hr to 400 m/hr. The filtration pressure increased with the packing-density increase. Below $80kg/m^3$ of packing density, the removal efficiencies of turbidity ad SS were less than 30% and 50%, respectively. At $100kg/m^3$ of packing density, the removal efficiencies of them were nearly 45% and 60% respectively. The filtration pressure increased with the filtration-velocity increase. A better removal efficiency was obtained at a lower filtration velocity, removal efficiency of them were 73% at 65 m/hr. Consequently, The filtration velocity was the more important factor to enhance the particle removal efficiency compared with the packing density in fiber filter.

Effect of Stuffing of TiN on the Diffusion Barrier Property(I) : Al/TiN/Si Structure (TiN의 충진처리가 확산방지막 특성에 미치는 영향(I) : Al/TiN/Si 구조)

  • Park, Gi-Cheol;Kim, Gi-Beom
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.87-95
    • /
    • 1995
  • The effect of stuffing of TiN on the diffusion barrier property between A1 and Si was investigated. The stuffing of TiN was performed by annealing in a Nz ambient at $450^{\circ}C$ for 30min. By TEM analysis, it is identified that there are solid-free or open spaces of a b u t 10-20$\AA$ between the grains of asdeposited TiN. In the case of stuffed TiN, the width of solid-free or open spaces has been reduced to about 10$\AA$ or below. The combination of RBS and AES analyses showed that the asdeposited TiN had about 7at.% of oxygen, and that the stuffed TiN had about 10-15at.% of oxygen. The diffusion barrier test result shows that after annealing at $650^{\circ}C$ for lhour, the asdeposited TiN fails due to the formation of A1 spikes and Si pits in the Si substrate. However, in the case of stuffed TiN, there is no indication of Al spikes and Si pits at the same annealing condition. Thus, it is concluded that this stuffing of TiN significantly improves the diffusion barrier property of TiN between A1 and Si. It is considered that the stuffing effect results from the reduced diffusion through grain boundaries due to the reduced spacing of grain boundaries.

  • PDF

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Mechanical Properties of NBR Rubber Composites Filled with Reinforced Fiber and Ceramics (강화섬유와 세라믹이 충진된 NBR 고무 복합체의 기계적 물성 특성)

  • Kwon, Byeong-Jin;Kim, Young-Min;Lee, Danbi;Park, Soo-Yong;Jung, Jinwoong;Chung, Ildoo
    • Journal of Adhesion and Interface
    • /
    • v.22 no.4
    • /
    • pp.118-127
    • /
    • 2021
  • In this study, the mechanical properties of vulcanized rubber were evaluated through compounding by controlling filler content to improve the mechanical properties of NBR rubber. Aramid and glass fibers with excellent heat resistance were used as fillers, and ceramics were additionally used in anticipation of a complementary effect, and as for the ceramic materials, needle-shaped and plate-shaped ceramics were used. Each filler was used in an amount of 5.0, 10.0, 15.0, and 20.0 phr in order to investigate the basic properties according to the amount of filler. To confirm the complementary effect through ceramic application, each 10.0 phr fiber and ceramic were mixed with 1:1 ratio to evaluate mechanical properties. As a result, it was confirmed that the decreasing ratio of tensile strength after heat aging was small in the order of aramid fiber, acicular ceramic, glass fiber, and plate ceramic in the case of applying the filler alone. In addition, the mechanical characteristics of vulcanized rubber using composite filler based on fibers and ceramics were evaluated, and it was confirmed that the composite filler had a complementary effect on thermal aging.

Self-Healing Properties in Cracking of Blast Furnace Slag Cement Paste (고로 슬래그 시멘트 페이스트 균열에서의 자기치유 특성)

  • Lee, Seung-Heun;Kang, Kook-Hee;Lim, Young-Jin;Lee, Se-Jin;Park, Byeong-Seon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • This study investigated the self-healing properties of blast furnace slag cement paste sample with $Na_2SO_4$ as a blast furnace slag activator after conducting the permeability test. Self-healing properties were examined by crack filling ratio and quantification of self-healing products. The degree of self-healing was evaluated by the crack filling ratio, and the crack filling ratio was analyzed by panoramic analysis using BSE-DIP for objectivity. The average crack filling ratio showed a tendency of decreasing from the upper part of the specimen to the lower part as the average of the top part was 18%, the middle part was 7% and the bottom part was 5% on average. The maximum crack filling ratio was 44% and the minimum crack filling ratio was 3%. The residual self-healing product after the permeability test contained a large amount of Ca element and Al element derived from the blast furnace slag, and the Si element was mainly present near the crack surface. The most abundant minerals in self-healing products were about 68% C-A-H. $CaCO_3$ was about 13% and C-A-S-H was about 8%. Three minerals accounted for 90% of self-healing products. C-A-H was mainly present at a part slightly distant from the crack surface and showed an angular or acicular shape. The C-A-S-H was generated on the surface naturally connected to the existing specimen, and the $CaCO_3$ was generally observed on the surface of the specimen or the inside of the crack.