Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle (암모니아-물 흡수식 열교환 사이클의 운전 특성)

  • 강인석;김남진;김종보
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.357-362
    • /
    • 2001
  • A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.

  • PDF

Evaluation of Treatability on DOC and THMs According to Periodic Cumulative Filling of Granular Activated Carbon (GAC) (입상활성탄 주기적 누적충진에 따른 용존유기탄소와 THMs 처리능 평가)

  • Son, Hee-Jong;Kim, Sang-Goo;Seo, Chang-Dong;Yoom, Hoon-Sik;Ryu, Dong-Choon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.513-518
    • /
    • 2017
  • In this paper, the removal efficiency of THMs (Trihalomethanes) and DOC (Disolved organic carbon) was compared under different GAC (Granual activated carbon) filling methods. One method is "full filling method" in which column is fully filled with GAC at once and the other is "periodic cumulative method" in which column is partially filled with GAC (10, 20, 33 and 50% of total column volume) and added each ratio during 300 days. The effluent concentration of both THMs and DOC under full filling method was low during the initial period, however, steadily increased with operating time. In the contrast, with periodic cumulative method, it maintained (relatively) evenly during the operating period. Periodic cumulative method was more efficient for removing THMs than full filling method. However, when the ratio of chlorodibromomethane or bromoform among THMs was significantly higher than chloroform and bromodichloromethane, full filling method was more efficient than periodic cumulative method. Full filling method had benefit to total DOC removal and control of average DOC concentration in effluent. Overall, periodic cumulative method is more efficient to equalize the removal efficiency of THMs and DOC, so the more frequent refilling of column with small amount of GAC is more advantageous.

PU-AC 고분자 담체를 이용한 염색폐수처리

  • 김서연;신원식;김영훈;송동익
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.05a
    • /
    • pp.312-315
    • /
    • 2004
  • 염색가공 공정에서 배출되는 염색폐수는 염색 가공공정이나 사용하는 염료등에 따라 폐수량과 성상의 변화가 심하기 때문에 처리에 많은 어려움이 있다. 일반적인 염색폐수 처리방법으로는 물리화학절인 응집침전법과 생물학적인 활성슬러지법을 단독 또는 조합하여 주로 사용하여 왔다. 그러나 최근에는 기존시설의 처리 향상을 위한 다각적인 기술개발이 시도되고 있으며 그 일환으로 본 연구에서는 활성탄을 담지한 폴리우레탄 담체를 개발하여 염색폐수를 처리하고자 하였다. 본 연구에서는 담체를 이용한 염색폐수의 생물학적 처리 시 여러 인자들, 즉 COD/N 비, DO 농도, 담체의 충진율 등의 영향을 조사하기 위하여 회분식 실험을 수행하였다. 또한 회분식 실험에서 얻은 최적조건을 이용하여 파일럿 실험도 함께 수행하였다. COD/N 비가 COD 제거에 미치는 영향을 살펴보기 위해 COD/N 비를 조절하지 않은 경우와 COD/N 비를 2-3으로 조절한 경우에 대해서 비교하였다. 실험결과 염색폐수의 초기 COD 농도가 1,000 ppm일 때, 처리 후 COD 농도는 COD/N 비를 조절하지 않았을 경우 860 ppm (제거효율 = 18%), COD/N 비가 2일 경우 550ppm (제거효율 = 52%), COD/N 비가 3의 경우 390 ppm (제거효율 = 57%)으로 각각 나타났다. DO 농도가 COB 제거에 미치는 영향을 알아보고자 DO 농도를 1, 6, 7 mg/L로 변화시켰다. 그 결과 DO의 농도가 1 mg/L일 경우 COD 제거효율은 20% 정도였으나, DO 농도가 6 mg/L이상에서는 모두 80%에 가까운 제거효율을 나타내었다. 담체 충진율의 경우, 10% 충진시 40%, 20% 충진시 50%, 30% 충진시 70%의 제거효울을 각각 나타내었다. 회분식 실험에서 얻은 최적조건으로 파일럿 반응기를 100일 이상 운전한 결과 염색폐수의 COD 농도변화는 1,000ppm에서 380ppm로 평균 60%이상 제거되는 높은 효율을 보였다. 또 담체 첨가의 영향을 살펴보기위해, 담체를 충진하지 않은 조건에서 파일럿 반응기를 운전한 결과 평균 COD 제거율은 50%로 비교적 낮은 효율을 보였다.

  • PDF

Prediction on heat and mass transfer coefficients in a packed layer of a regenerator with a solar desiccant cooling system (태양열제습냉방시스템 중 재생기의 충진층 내 열물질 전달계수에 관한 예측)

  • Eflita, Yohana;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.36-42
    • /
    • 2010
  • 본 논문은 태양열이용 냉난방시스템 중에서 실제로 액체흡수제를 재생하는 재생탑 내의 충진층에 있어서의 열 및 물질전달의 실험치와 이론적 해석에 의한 결과치와의 비교를 나타내고 있다.특히 물질전달의 극대화를 위하여 충진층 내에서 공기와 흡수제의 접촉면적을 크게 할 필요가 있는데,이를 위해서 본 실험에서는 직경이 3cm인 플라스틱제 충진재를 사용하였으며, 흡수제로는 저농도의 염화리튬 수용액이 사용 되었다. 충진층 내에서의 최적 높이를 예측하기 위하여 해석의 모델인 실험장치를 직접 제작하여 실험을 수행하였고, 이론 해석에 있어서 체적 열전달을 고려한 정상상태를 모델화하여 해석하였다. 이 결과, 충진층 내에서 실험치와 이론적인 계산치가 잘 일치함을 알 수 있었으며, 충진층의 높이가 2m 이상인 경우에는 높이에 따른 재생량의 차이가 없어서 없음을 알 수 있었다.

Removal Characteristics of VOCs Using Biofiltration (생물여과를 이용한 휘발성 유기화합물의 제거특성)

  • 윤인길;박찬엘;박창호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.409-410
    • /
    • 2000
  • 생물여과 (biofiltration)로 알려진 기술은 오염물을 gas stream이나 liquid stream을 사용하여 생물학적으로 처리할 수 있다. 주요 방법으로 생물세정 방법과 생물여과의 두 방법을 사용하고 있다. 오염물질 제거효율에 영향을 미치는 인자로는 오염물질의 종류와 특징, 오염물질의 유입농도, 충진물의 종류와 형상, 오염물질이 충진물에 머무름 시간 등이 있다. 일반적으로 생물 여과에 있어서 반응기의 충진물로 compost, peat, wood chips와 토양을 이용하거나 또는 활성이 없는 합성 매체를 이용하기도 한다(Leson and Winer, 1991). (중략)

  • PDF

The Effects of Leukocyte Depleted Priming Solution on the Gastric Mucosal $Co_{2}$ Partial Pressure and Serum IL-8 Level during Cardiopulmonary Bypass in Korean Mongrel Dogs (한국산 잡견에서 백혈구 제거 충진액이 체외순환 중 위점막 이산화탄소 농도와 IL-8 수준에 미치는 영향)

  • Park Kuhn;Lee Jong Ho;Kim Jin Ho;Jin Ung;Kwon Jong Bum;Kim Chi Kyeong;Wang Young Pil
    • Journal of Chest Surgery
    • /
    • v.38 no.12 s.257
    • /
    • pp.807-814
    • /
    • 2005
  • Background: Cardiopulmonary bypass is an essential process to maintain circulation for saving life during the cardiac surgery, But it is a process in which systemic inflammation was evoked inevitably because of the exposure of blood to foreign surface. The injuries to distal organs during the cardiopulmonary bypass were resulted from systemic inflammation and the disturbances of micro-circulations in the organs. We designed this study to research the effects of leukocyte depletion from pump-oxygenator priming solution on the systemic inflammation, and the micro-circulation of gastric mucosa that is suggested by the gastric mucosal $CO_{2}$ partial pressure and acidity. Material and Method: The dogs were divided into three groups according to the different pump-oxygenator priming solutions; non-hemic crystalloid solution; leukocyte-depleted homologous blood; and non leukocyte-depleted homo-logous blood. Each priming solution group contained five dogs. In all three groups, 2 hours of cardiopulmonary bypass, and 4 consecutive hours of general anesthesia was maintained on the mechanical ventilation. Each dog was evaluated for the gastric mucosal pH, $CO_{2}$ partial Pressure, arterial pH, $CO_{2}$ partial pressure, the exhaled air $CO_{2}$ partial pressure and the level of IL-8 on before the cardiopulmonary bypass, 1 hour after the cardiopulmonary bypass, 2 hours after the cardiopulmonary bypass, 2 hours after the restoration of normal circulation, and 4 hours after the restoration of normal circulation after the cardiopulmonary bypass. The levels of IL-8 were measured with ELISA (enzyme linked immunosorbent assay) technique. Result: 1. There were significant differences of gastric mucosal $CO_{2}$ partial pressure between the leukocyte-depleted homologous blood group and other two groups(vs non leukocyte-depleted homologous blood group; P=0.02, vs non-hemic crystalloid solution group; P=0,01). 2. The gastric mucosal pH of leukocyte-depleted homologous blood group was significantly different from non leukocyte-depleted homologous blood group (p=0.01). 3. The levels of IL-8, which examine the systemic inflammation, showed signi- ficantly better results in leukocyte-depleted homologous blood group and non-hemic crystalloid solution group than non leukocyte-depleted homologous blood group (p=0.01, 0.01). Conclusion: Based upon these results, we concluded that the leukocyte depletion from the pump-oxygenator priming solution has a beneficial effects in reducing systemic inflammation and the preserving of gastric mucosal micro-circulation.

토양컬럼을 이용한 합성폐수증 $NH^{4+}$의 질산화

  • 정경훈;정오진;최형일;박상일;김해연
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.05a
    • /
    • pp.329-331
    • /
    • 2004
  • 본 연구에서는 토양을 충진한 컬럼을 사용하여 질산화 반응을 촉진시키기 위한 첨가제에 따른 효과를 검토하였다. 토양만을 충진한 컬럼에서는 $NH_{4-}$/N의 약 26%가 질산화 되었으며 제올라이트를 첨가 하였을 때 실험초기에는 $NH_{4-}$/N가 유출되지 않다가 20일 이후부터 $NH_{4-}$/N의 농도가 증가 하기 시작하였으며 이는 제올라이트에 의한 흡착능력의 저하로 사료된다. 폐굴껍질 20% 충진한 토양컬럼에서는 실험 95일까지 99.7%의 질산화율을 보았다. 위의 결과로부터 알 수 있듯이 토양컬럼에 폐굴껍질과 제올라이트를 첨가제로 충진하였을 경우 질산화 반응을 촉진시켜서 질산화율을 높일 수 있음을 확인 할 수 있었다.

  • PDF

Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator (확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Optimal removal of taste & odor and natural organic matter by activated carbon adsorption (활성탄 흡착에 의한 이취미 및 천연유기물질의 최적 제거 방안)

  • Chae, Seon-Ha;An, Chang-Jin;Jeon, Hang-Bae;Wang, Chang-Geun
    • 수도
    • /
    • v.23 no.6 s.81
    • /
    • pp.30-35
    • /
    • 1996
  • 조류의 성장에 기인하여 대청호로부터 발생된 이취미와 천연유기물질의 제거를 위해 활성탄 흡착에 관한 파일롯 플랜트연구를 수행하였다. 대청호원수의 용존유기물질 농도는 1.5-3.5mg/1으로 나타났고, 이취미를 유발시킨 주 성분인 Geosmin농도는 가을에 60ng/1 이상이 검출되었다. 이는 8월말부터 발생하기 시작하여 10월말 까지 지속되었다. 이는 8월말부터 발생하기 시작하여 10월말 까지 지속되었다. 한국수자원공사 대청수도내 파일롯 플랜트는 재래식정수처리 시스템에 오존산화공정, 4개의 입상활성탄 흡착탑으로 구성되었다. 공탑체류시간(EBCT) 15분 이상에서, 이취미 발생기간동안 GAC 3지와 4지에서 이취미는 완전히 제거되었다. 활성탄 원료 종류별 DOC제거를 위한 파일롯연구에서 석탄계 활성탄으로 충진한 GAC 3지와 4지는 운전 3개월 후에 파괴되기 시작하였고, 이 후 4개월의 운전동안 약 40-50%의 일정한 제거효율을 보여주었다. 야자계 활성탄으로 충진된 GAC 2지는 2개월의 운전 후에 완전히 파괴되었다.

  • PDF