• Title/Summary/Keyword: 충전 방식

Search Result 392, Processing Time 0.028 seconds

Success and failure of endodontic microsurgery (미세 치근단 수술의 성공과 실패)

  • Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.465-476
    • /
    • 2011
  • In current endodontic practice, introduction of operating microscope, ultrasonic instruments, and microinstruments has induced a big change in the field of surgical retreatment. In this study, we aimed to offer key steps of endodontic microsurgery procedure compared with traditional root-end surgery, and to evaluate factors influencing success and failure based on published articles. Endodontic microsurgery is a surgical procedure performed with the aid of a microscope, ultrasonic instruments and modern microsurgical instruments. The microscope provides magnification and illumination - essential for identifying minute details of the apical anatomy. Ultrasonic instruments facilitate the precise root-end preparation that is within the anatomical space of the canal. Modern endodontics can therefore be performed with precision and predictability, thus eliminating the disadvantages inherent in traditional periapical surgery such as large osteotomy, beveled apicoectomy, inaccurate root-end preparation and the inability to observe isthmus. Factors influencing the outcomes of endodontic microsurgery may be diverse, but standardization of procedures can minimize its range. Among patient and tooth-related factors, periodontal status and tooth position are known to be prognostic, but there are only few articles concerning this matter. High-evidence randomized clinical trials or prospective cohort studies are needed to confirm these findings.

Current Status and the Way Forward for Fruit Harvesting Mechanization (과수 수확작업 기계화 현황 및 추진방향)

  • Kim, Young-jin;Choi, Kyu-hong;Kim, Seong Min
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.53-53
    • /
    • 2017
  • 연구목적: 국내 과일 산업의 한 단계 도약과 대외 경쟁력을 높이기 위해서는 수확작업의 기계화가 시급함. 이 연구는 국내외 과일 수확 기계화 현황과 문제점을 분석하고, 향후 수확작업 기계화 방향을 제시하고자 수행 수확기계 실용화 현황 및 고찰 (국내) 과일을 직접 수확이 아닌 수확 작업을 보조해주는 고지 작업기(수동형, 모터 진동형)와 고소 작업차가 대부분임. 수동형은 사과 감 등을 수확하지만, 작업능률이 낮고 작업자가 쉽게 피로하여 장시간 작업이 불가능하므로 실질적인 대안이 되지 못함. 진동형은 자체 동력을 이용하여 나무에 진동을 가하여 주로 대추 매실 등 소과류 수확에 이용되고, 수확능률은 우수하나 충격 손상이 많아 개선이 요구됨. 고소작업차는 동력원에 따라 충전식과 엔진식으로 구분되고, 충전식은 엔진식에 비해 진동 소음이 적어 쾌적하지만, 작업시간이 배터리 용량에 제한을 받음. 또한 작업대 작동방식에 따라 리프트형과 붐형으로 구분함. 리프트형은 리프트를 이용하여 작업대를 상하로 구동하는 방식으로 높은 위치의 과실 수확이 어렵고, 작업대 넓이 만큼의 작업 공간(과수간의 거리)이 필요함. 붐형은 필요한 곳으로 접근성이 우수하나 무거운 무게를 지탱하기 어렵기 때문에 본체를 무겁게 하거나 수시로 수확된 과일을 하차시켜야 함. (국외) 수확 후 가공되는 과일류와 포도 올리브 오렌지 매실 등 소과류 수확이 기계화되었지만, 사과 복숭아 등 신선과일은 아직도 외국의 값싼 노동자들에 의존하여 수확되고 있음. 현재 실용화된 수확 기계는 진동식 수확기계와 터널식 수확기계가 대표적임. 진동식은 집게형의 부착기를 나무 줄기에 고정한 후 트랙터 동력원으로 나무에 진동을 가하여 수확하고, 올리브 대추 등과 같은 소과류와 과피가 두꺼운 오렌지 등에 적용되고, 수확 작업능률이 매우 높으나 과일의 낙하 상처를 피할 수 없는 단점이 있음. 터널형은 규격화(과수 크기 및 형태, 재식거리)된 과수원에 잘 적응하도록 설계 제작되어, 과수 위를 지나가면서 내부에 설치된 진동장치와 컨테이너로 과일을 수확하고, 와인용 포도 수확기가 대표적임. 기계수확이 가능하도록 과수원 조성단계에서부터 재배양식(과수 좌우 및 전후 거리)을 기계의 제원(바퀴 간격, 작업부 간격 등)에 맞추어 재배함. 과일 수확로봇에 관한 연구는 활발하고 일부에서 실증시험단계에 있음. 결론: 구체적인 추진방향을 제시하면, 단기적으로는 과일 수확작업자의 작업편이성과 노동강도를 줄일 수 있도록 소형 저가 범용성이 우수한 보조기구/기계의 보급을 확대하고, 중장기적으로는 수확기계/수확로봇 개발을 위한 연구개발비 투자를 늘리는 동시에, 기계/로봇이 과수원에 잘 적응할 수 있도록 수형 재식거리 등 재배양식의 표준화가 추진되어야 함.

  • PDF

Railway Access Alarm System Using Infrared Distance Sensor and Wireless Communication (적외선 센서와 무선통신을 이용한 열차접근경보시스템 개발)

  • Hwang, Yun-Tae;Hwang, Sung-Tae;Lee, Yun-Sung;Kim, Do-Keun;Lee, Tae-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.303-311
    • /
    • 2017
  • Safety accidents in railway work continue to increase every year; Engineer's negligence, trackside worker's sensory deprivation and signalman's mistake are the main reasons of such incidents. We consider this problem by far the most urgent matter in railway work because of its steady increase and risk of taking a person's life. Based on that account, a new alarm system has developed, that is called Railway Access Alarm System, to allow railway workers to sense the access of trains with not only vision, but also hearing. The detector device of this system is installed on both sides of the track locating 1.5km from the workplace. When the train enters the place, the detector device can sense the entering, sending the detect sign of train to the alarm unit, then the alarm unit warns the workers by the LED lighting and sirens. This system has several advantages compared to previous systems. First, it recognizes the train at a long distance. Secondly, there is no need for wiring work since it is a wireless system. At last, the system works by rechargeable batteries and solar charger so that it is installed in the work places where there is no external power supply. Moreover, it is proven that the system is 100% reliable by the successful on-the spot inspection evaluating the capability.

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

Treatment of Synthetic Wastewater by Indirect Aerating Biofilter Submerged Gravel (잔자갈을 충전(充塡)한 간접폭기방식(間接曝氣方式) 침지여상(浸漬濾床)에 의한 합성하수처리(合成下水處理))

  • Yang, Sang Hyon;Won, Chan Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.129-138
    • /
    • 1988
  • In order to develop the design and operational criteria in sewage treatment by indirect aerating submerged biofilter, experimental investigations were performed for the reasonable oxygen supply and effecting factors of treatment efficiency. The experiments were executed for the up-flowing synthetic wastewater and aerated water in the submerged biofilter at $20^{\circ}C$. The obtained results are as follows: 1) Appropriate mean diameter of gravels was about 11mm. 2) $BOD_5$ loading rate based on biofilter volume was more reasonable than that on surface area of gravel for operational criteria. 3) To remove the influent $BOD_5$ more than 90%, $BOD_5$ loading rate must be less than $1.0kg-BOD_5/m^3{\cdot}d$ and circulating flowrate must be more than $189m^3/m^3{\cdot}d$. 4) Reaction rate coefficient $K_1$ is related to diameter of gravel and circulating flow rate based on biofilter volume.

  • PDF

A Study on Discharge Characteristics from the Nozzle Orifice Attached to a Modularized Fire Extinguishing Gas-agent Container Under Horizontal Position (용기 일체형 가스소화 방식의 오리피스 방사 특성에 관한 연구)

  • 김윤증;윤명오;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.59-69
    • /
    • 2002
  • The conventional fire extinguishing gas-agent system has a configuration in which the gas-agent comes out of a cylindrical container having vertically settled shape. However, in this study a horizontally installed container of a piping shape having a cylinder of the same shape with a cylinder valve and a discharge nozzle was used, and the relationship between orifice size of nozzle and discharge rate of gas-agent was investigated through various experiments including the measurement of discharge rate under different ambient-temperature conditions. In such experiments, HCFC Blend A was used without super-pressurization by nitrogen. From this research, it was observed that statutory discharge duration of 10 seconds can be met if the relatively large size of the valve and the nozzle orifice were properly selected.

Design of High-Speed EEPROM IP Based on a BCD Process (BCD 공정기반의 고속 EEPROM IP 설계)

  • Jin, RiJun;Park, Heon;Ha, Pan-Bong;Kim, Young-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.455-461
    • /
    • 2017
  • In this paper, a local DL (Data Line) sensing method with smaller parasitic capacitance replacing the previous distributed DB sensing method with large parasitic capacitance is proposed to reduce the time to transfer BL (Bit Line) voltage to DL in the read mode. A new BL switching circuit turning on NMOS switches faster is also proposed. Furthermore, the access time is reduced to 35.63ns from 40ns in the read mode and thus meets the requirement since BL node voltage is clamped at 0.6V by a DL clamping circuit instead of precharging the node to VDD-VT and a differential amplifier are used. The layout size of the designed 512Kb EEPROM memory IP based on a $0.13{\mu}m$ BCD is $923.4{\mu}m{\times}1150.96{\mu}m$ ($=1.063mm^2$).

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

The Structural Design of the Bus-bar block type of electrical switch boards (전기분전반용 블록형 부스 바의 구조 설계 연구)

  • Kwon, Young-min;Hwang, Chang-yu;Kim, Kyun-ho;Han, Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.378-385
    • /
    • 2016
  • The internal circuit of the bus-bar for an electrical switch board is a prime cause of electric shock and short circuit accidents due to the exposure of live parts. Electrical fires can also be caused by animals and foreign substances in the switchboard that connect the components with a difficult structure resulting in overheating due to an increase in contact resistance. Preventing these types of accidents is a prime concern in the manufacturing process, such as cutting and bending. In this study, the cutting bus bar of a switch board contained improved modules as a flame retardant that isolates a separate blocks to prevent such problems. This was implemented as a scalable and flexible means of reducing electrical switchboard hazards to offer a safe switch board bus-bar structure of a new connecter type

Fire Cause Reasoning of Self-regulating Heating Cable by a Fire Investigation Applying the Scientific Method and Fault Tree Analysis (과학적 방법을 적용한 화재조사와 결함수 분석을 이용한 정온전선의 발화원인 추론)

  • Kim, Doo-Hyun;Lee, Heung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.73-81
    • /
    • 2016
  • A self-regulating heating cable is an electrical heating element by flowing an electric current between parallel conductors filled with an extruded semi-conductive polymer. Self-regulating heating cables are used mainly for frost protection purposes because the construction is convenient and the price is low. On the other hand, structural problems with imperfections of the insulation can cause a fire despite their usefulness. This paper deduced a direct method to derive the cause by investigating the scene of a fire due to a self-regulating heating cable and analyzed the basic problem using fault tree analysis. In this paper, the actual fire scene was a cold storage warehouse, and fire investigation was conducted. After investigating the fire scene and fault tree analysis, the cause of the fire could be attributed to dielectric breakdown of the self-regulating heating cable. This paper could be utilized in the fire safety activities and similar fire investigations.