• Title/Summary/Keyword: 충전현상

Search Result 254, Processing Time 0.023 seconds

Charging of an Ionic Liquid Droplet in a Dielectric Medium (비전도성 매질 내 이온성 액체 액적의 충전 현상)

  • Im, Do Jin
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.354-358
    • /
    • 2014
  • Ionic liquid (IL) is a salt presents in a liquid form at room temperature. Recently, it attracts huge attention due to its possibilities as a clean solvent, electrolyte, and catalyst. In the present work, the charging behavior of six different ILs were investigated using droplet contact charging phenomenon in a dielectric medium. Basically, the charging of an IL droplet can be explained by a perfect conductor theory. However, there were several different features depending on the species of ions of ILs, which requires rigorous molecular level modeling of charge transport through electrochemical reaction of IL. We hope the present results contribute to build up fundamental understanding of electrochemical charge transport of IL.

LPG충전소의 BLEVE현상에 따른 피해 분석

  • Jo, Sam-Gyu;Kim, Tae-Hwan;Ham, Eun-Gu
    • LP가스
    • /
    • s.67
    • /
    • pp.26-32
    • /
    • 2000
  • 도심지내에 위치한 부천 LPG충전소 사고 조사를 통하여 가장 피해효과가 큰 탱크로리 폭발에 따른 결과를 분석하였다. 분석범위는 BLEVE 현상에 의한 방출열과 과압이 충전소 주변에 위치한 구조물이나 인체에 미치는 영향을 대상으로 실제 현장조사를 통하여 수집된 피해결과와 이론적인 모델(PHAST-Process Hazad Analysis Software Tools) 분석 결과를 비교하였다. 부천 LPG 충전소 폭발 사고의 피해효과는 방출열의 경우 두 가지 모두 큰 차이를 보이지 않았으나 과압의 경우, 실제 피해는 이론적 모델 분석결과의 약 15%정도에 해당하는 축소된 거리에서 나타났다. 또한 충전소 인근에 위치한 구조물에 대한 피해효과는 부분적으로 과압에 의한 균열 및 붕괴 현상보다는 열 효과에 의한 콘크리트 강도 저하와 성상변화가 크게 나타났다.

  • PDF

Investigation of the Filling Unbalance and Dimensional Variations in Multi-Cavity Injection Molded Parts (다수 캐비티의 사출성형품에서 충전의 불균형과 성형품 치수 편차의 교찰)

  • Kang, Min-A;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.501-508
    • /
    • 2008
  • Small injection molded articles such as lens and mobile product parts are usually molded in multi-cavity mold. The problem occurring in multi-cavity molding is flow unbalance among the cavities. The flow unbalance affects the dimensions and physical properties of molded articles. First of all, the origin of flow unbalance is geometrical unbalance of the delivery system. However, even the geometry of the delivery system is well balanced, cavity unbalance occurs. This comes from the temperature distributions in the cross-section of runner. Temperature distribution depends upon injection speed because heat generation near runner wall is high at high injection speed. Among the operational conditions, injection speed is the most significant process variable affecting the filling unbalances in multi-cavity injection molding. In this study, experimental study of flow unbalance has been conducted for various injection speeds and materials. Also, the filling unbalances were compared with CAE results. The dimensions and weights of multi-cavity molded parts were examined. The results showed that the filling unbalances vary according to the injection speeds and resins. Subsequently, the unbalanced filling and pressure distribution in the multi-cavity affect the dimensions and physical states of molded parts.

Contact Charging and Electrphoresis of a Glassy Carbon Microsphere (유리상 탄소입자의 직접 접촉충전에 의한 전기영동 현상연구)

  • Choi, Chang Yong;Im, Do Jin
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.568-573
    • /
    • 2016
  • We investigated the charging characteristics of a conducting solid sphere (glassy carbon sphere) comparing with that of a water droplet and check the applicability of the perfect conductor theory. For the systematic research, sphere size, applied voltages, viscosity of the medium were changed and the results were compared with that of corresponding water droplets and the perfect conductor theory. Basically, a glassy carbon sphere follows the perfect conductor theory but the charging amount was lower as much as 70~80% of theoretical prediction value due to oil film formed between electrode and a carbon sphere. We hope this result provides basic understandings on the solid sphere contact charging phenomenon and related applications.

A study on the runner system for filling balance in multi-cavity injection molds (다수 캐비티 사출금형에서의 균형 충전을 위한 러너 시스템 연구)

  • Jeon, Kang-Il;Noh, Seung-Kyu;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1581-1588
    • /
    • 2011
  • In this study, flow characteristics in a multi-cavity injection molding process were investigated. One of main problems occurred in the multi-cavity molding is a flow imbalance among cavities since it affects physical properties and quality of products. Charge imbalance is caused by the uneven shear stress. Therefore, changes in viscosity affect the physical properties of resin and injection conditions differ in the filling imbalance phenomenon. Through, this study focus on experimental studies of flow imbalance for PC and PP resin occurring in a balanced delivery system. Experimental results were compared with CAE results. By experimental and CAE analysis, main cause for the flow imbalance is temperature distribution in cross section of runner. New runner system with a simple change of runner shape was suggested to avoid the flow imbalance. A series of simulation to confirm feasibility of Volume Runner's effects was conducted using injection molding CAE.

Battery Based High Voltage Capacitor Charger for HEMP Driving (HEMP 구동을 위한 배터리 기반 고전압 충전기)

  • Cho, Chan-Gi;Jia, Ziyi;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.124-126
    • /
    • 2019
  • 본 논문은 리튬 폴리머 배터리를 기반으로 하여 High-altitude Electromagnetic Pulse (HEMP)를 구동하는 고전압 충전기의 2단 충전과 직접 충전 방법에 관하여 다룬다. 2단 충전 방법은 삼상 변압기의 출력 전압을 정류한 600 V의 전압에 공진 현상을 이용하여 최종 출력 전압 1.0 kV을 생성하는 반면, 직접 충전 방법은 공진 현상을 이용하지 않고 삼상 변압기의 출력 전압을 정류하여 1.0 kV를 생성한다. 두 방법 모두 1.0 kV의 출력 전압을 생성하는 점은 동일하지만, HEMP 구동을 위해서는 서로 다른 고려사항을 갖는다. 이에 따라, 시뮬레이션 및 기초 부하 실험을 통해 2단 충전 구조와 직접 충전 구조의 차이점, 그리고 충전기와 부하의 결선에 따른 차이점이 비교되었다.

  • PDF

CAE Simulation Study an Filling Imbalance in Multi-Cavity Injection Molding (다수 캐비티 사출성형에서 충전 불균형 현상에 관한 시뮬레이션)

  • Jeon, Kang-Il;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.678-681
    • /
    • 2009
  • 사출성형은 열가소성수지의 가공법으로써 정밀도나 고품질의 제품을 효과적으로 생산하는데 널리 이용되며 플라스틱은 현재 광범위하게 사용되고 있는 공업재료 중의 하나이다. 과거에는 플라스틱을 일회용품 및 외장재로 사용하였다. 그러나 산업기술이 발전하며 플라스틱은 금속을 대체 할 수 있는 재료로서 사용할 수 있다는 인식의 변화로 점차 기계요소용 재료로 사용되고 있으며 기계요소용 재료로 사용됨에 따라 플라스틱 제품이 정밀한 부품으로 사용되기 위해서는 금형의 가공뿐만 아니라 사출성형 시 용융수지가 금형의 각 캐비티에 균형적으로 충전되는것이 요구된다. 이러한 요구조건을 만족하기 위해서는 각 캐비티의 가공치수는 매우 높은 정밀도를 유지해야 하며, 각 캐비티에서의 충전과 냉각도 동일한 상태를 유지해야 한다. 충전 불균형은 성형품의 품질에 큰 저해 요인으로서 플라스틱 제품의 치수성, 밀도, 외관품질, 강도 등에 불균일한 결과를 가져오는 요인으로 지적되고 있다. 실제로 충전 불균형은 충전 단계에서 런너 내에서 발생하는 불균일한 전단분포에 기인하여 발생되므로 점도변화에 영향을 주는 수지의 물성, 런너의 배열과 같은 외부 요인과 사출압력, 사출속도, 수지온도, 금형온도와 같은 성형공정 조건에 의한 요인에 의한 충전 불균형의 양상이 달라지게 된다. 본 연구는 다수 캐비티 금형에서 충전 불균형 현상에 대한 원인을 검토하고 실제로 사출성형을 실시하기 전 사출성형해석 소프트웨어를 이용하여 시뮬레이션을 하여 다수 캐비티에 대한 충전 패턴을 미리 예측하여 보았다.

  • PDF

A Study on The Efficient Fast Charging Method considering Battery Temperature (배터리 온도를 고려한 효율적인 고속 충전 방법에 관한 연구)

  • Kim, Jae-Jin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.519-520
    • /
    • 2018
  • 본 논문에서는 배터리의 온도를 고려하여 효율적으로 고속 충전할 수 있는 방법에 대해 제안하였다. 제안된 방법은 충전하고자 하는 배터리의 온도에 따라 충전에 필요한 전압과 전류의 양을 조절하여 최적의 충전 환경을 만들어 배터리의 수명을 감소시키지 않는 최적의 충전 환경을 제공하는 것이다. 충전으로 인하여 배터리 내부에 있는 전해액, 활물질, 분리막 등의 반응성이 증가되어 배터리의 온도 상승과 수명 단축이 발생되는 현상을 고려하여 배터리의 열 발생으로 저하되는 충전량을 보상할 수 있도록 전압 또는 전류의 량을 조절하여 초기의 충전량을 유지할 수 있도록 하는 고속 충전 방법이다. 제안한 방법의 효율성을 검증하기 위해 리튬이온 배터리를 이용하여 일반적인 충전과 비교하여 실험하였다. 실험 결과 존 논문에서 제안한 방법이 기존의 충전방법보다 고속으로 충전되어 효율성이 입증되었다.

  • PDF

Mixed-mode transient analysis of CDM ESD phenomena (CDM ESD 현상의 혼합 모드 과도 해석)

    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.1-1
    • /
    • 2001
  • 2차원 소자 시뮬레이터를 사용하는 혼합모드 과도해석 방법을 제시하여, NMOS 트랜지스터를 ESD 보호용 소자로 사용하는 CMOS 칩에서의 충전소자모델(CDM) ESD 현상에 대한 분석을 시도하였다. 과도해석 결과의 분석을 통해 CDM 방전 경우 소자 파괴에 이르는 미케니즘에 대해 상세히 설명하였고 충전전기의 극성에 따른 방전 특성의 차이점도 비교 분석하였다. CDM 방전에서 가장 문제가 되는 입력버퍼의 게이트 산화막 파괴문제와 관련하여 배선저항 값의 변화에 의한 영향을 검토하였고, 입력버퍼회로 보호용 NMOS 트랜지스터의 추가에 의한 방전 특성의 변화에 대해 조사하였다.

Runner design for Fillingbalance in Multi-cavity Injection molding (사출성형에서 균형충전을 위한 러너 설계)

  • Noh, Seung-Kyu;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1245-1248
    • /
    • 2010
  • 플라스틱은 가공이 용이하기 때문에 우리 생활에 널리 이용되고 있다. 과거에는 단순히 제품의 외장제로 이용되었지만 산업이 발달함에 따라 금속을 대체 할 정도로 사용 범위가 증가하고 있다. 또한 사용량이 증가함에 따라 제품의 생산량을 증가시키기 위해선 다수 캐비티의 금형 사용이 필수적으로 되었다. 다수 캐비티 사출성형에서 각 캐비티 간 제품의 품질 및 물성을 향상시키기 위해선 각 캐비티로 충전되는 수지가 균형을 이루어야 한다. 하지만 기하학적으로 균형을 갖추고 있는 러너를 설계하여도 실제 사출성형에서는 불균형 충전이 일어나게 된다. 이러한 불균형 충전은 미국의 Beaumont에 의해서 처음 규명된 뒤 충전불균형 현상을 해결하기 위해 많은 연구가 진행되었다. 본 논문에서는 다수 캐비티 사출성형에서 균형충전을 위한 러너시스템을 제안하였다. 이 러너시스템은 온도가 불균일한 수지의 흐름을 혼합함으로써 수지의 흐름을 균일하게 하여 균형충전을 이루도록 하였다. 또한 사출성형해석프로그램인 Moldflow를 이용한 유동해석을 통해 그 효과를 나타내 보았다.

  • PDF