• Title/Summary/Keyword: 충전한계

Search Result 107, Processing Time 0.025 seconds

Method for evaluating the safety performance and protection ability of the mobile steel protective wall during the high-explosive ammunition test (고폭탄 탄약시험 간 이동형 강재 방호벽의 안전성능 판단 및 유효 방호력 평가 방법)

  • Jeon, In-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.573-582
    • /
    • 2021
  • In this study, a series of processes for evaluating the effective protection against barriers that should be equipped in institutions that perform reliability tests on high-risk ammunition, such as high-explosive ammunition, were introduced. The impact that high-explosive bombs can have on personnel includes damage to the eardrum and lungs caused by explosion overpressure and penetrating wounds that can be received by fragments generated simultaneously with the explosion. Therefore, a high-explosive with COMP B explosives as its contents were set up, and an explosion protection theory investigation to calculate the degree of damage, numerical calculations and simulations were performed to verify the protection power. A numerical calculation revealed the maximum explosion overpressure on the protective wall when the high-explosive exploded and the penetration force of the fragment against a 50 mm-thick protective wall to be 77.74 kPa and 41.34 mm, respectively. In the simulation verification using AUTODYN, the maximum explosion overpressures affecting the firewall and personnel were 56.68 kPa and 18.175 kPa, respectively, and the penetration of fragments was 35.56 mm. This figure is lower than the human damage limit, and it was judged that the protective power of the barrier would be effective.

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

A Study on Establishment of the Optimum Mountain Meteorological Observation Network System for Forest Fire Prevention (산불 방지를 위한 산악기상관측시스템 구축방안)

  • Lee, Si-Young;Chung, Il-Ung;Kim, Sang-Kook
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.1
    • /
    • pp.36-44
    • /
    • 2006
  • In this study, we constructed a forest fire danger map in the Yeongdong area of Gangwon-do and Northeastern area of Gyeongsangbuk-do using a forest fire rating model and geographical information system (GIS). We investigated the appropriate positions of the automatic weather station (AWS) and a comprehensive network solution (a system including measurement, communication and data processing) for the establishment of an optimum mountain meteorological observation network system (MMONS). Also, we suggested a possible plan for combining the MMONS with unmanned monitoring camera systems and wireless relay towers operated by local governments and the Korea Forest Service for prevention of forest fire.

Assessment of the Potential Consumers' Preference for the V2G System (V2G 시스템에 대한 잠재적 소비자의 선호 평가)

  • Lim, Seul-Ye;Kim, Hee-Hoon;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.93-102
    • /
    • 2016
  • Vehicle-to-Grid (V2G) system, bi-direction power trading technology, enables drivers possessing electric vehicle to sell the spare electricity charged in the vehicle to power distribution company. The drivers gain profit by charging electricity in the day time of high electricity rate. In this regard, the government is preparing the policies of building and supporting V2G infrastructure and demanding the potential consumers' preference for the V2G system. This paper attempts to analyze the consumers' preference using the data from obtained a survey of randomly selected 1,000 individuals. To this end, choice experiment, an economic technique, is employed here. The attributes considered in the study are residual amount of electricity, electricity trading hours, required plug-in time, and price measured as an amount additional to current gasoline vehicle price. The multinomial logit model, which requires the assumption of 'independence of irrelevant alternatives', is applied but the assumption could not be satisfied in our data. Thus, we finally utilized nested logit model which does not require the assumption. All the parameter estimates in the utility function are statistically significant at the 10% level. The estimation results show that the marginal willingness to pay (MWTP) for one hour increase in electricity trading hours is estimated to be KRW 1,601,057. On the other hand, a one percent reduction in residual amount of electricity and one hour reduction in required plug-in time in V2G system are computed to be KRW -91,911 and -470,619, respectively. The findings can provide policy makers with useful information for decision-making about introducing and managing V2G system.

Oral Health Status of Some Patients with Chronic Mental Illness in Korea (일부 만성 정신질환자의 구강건강 상태)

  • Seo, Hye-Yeon;Jeon, Hyun-Sun;Park, Su-Kyung;Park, Ki-Chang;Chung, Won-Gyun;Mun, So-Jung
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.493-500
    • /
    • 2013
  • The study aims to determine the status of oral health of mental illness patients and establish the preliminary data. The examinations and questionnaire survey were done 92 psychiatric patients to measure sociodemographic characteristics, decayed, missing and filled teeth (DMFT) index, patient hygiene performance (PHP) index, community periodontal index of treatment need (CPITN). Result of the missing teeth index in the state of oral health was higher in the hospital group (6.42) while the filled teeth index was higher in the center group (4.78). In the DMFT index, mental illness patients were higher than the national sample. The oral health status of medical aid recipients was poorer as the subjects were older and less educated (p<0.05). The PHP index was 3.41, close to the bad oral hygiene state. The hospital group (81.7%) required higher need for periodontal treatment. The periodontal health state was much poorer especially when the subject was in the age of 40's and 60's, received less education, and had no family (p<0.05). $CPITN_3$ was higher in the hospital group (13.3%) than the national sample (5.7%). The mental illness patients were socially vulnerable, therefore oral health care program should be needed and age, education level, health insurance type, presence of family and other factors needs to be considered in this approach.

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

A study on the calibration characteristics of organic fatty acids designated as new offensive odorants by cryogenic trapping-thermal desorption technique (유기지방산 신규악취물질에 대한 저온농축 열탈착방식 (Thermal desorber)의 검량특성 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Im, Moon-Soon;Ju, Do-Weon
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.488-497
    • /
    • 2009
  • In this study, analytical methodology for several organic fatty acids (OFA: propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) designated as new offensive odorants in Korea (as of year 2010) was investigated along with some odorous VOCs (styrene, toluene, xylene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol). For this purpose, working standards (WS) containing all of these 13 compounds were loaded into adsorption tube filled with Tenax TA, and analyzed by gas chromatography (GC) system thermal desorber interfaced with. The analytical sensitivities of organic fatty acids expressed in terms of detection limit (both in absolute mass (ng) and concentration (ppb)) were lower by 1.5-2 times than other compounds (PA: 0.24 ng (0.16 ppb), BA: 0.19 ng (0.11 ppb), IA: 0.15 ng (0.07 ppb), and VA: 0.28 ng (0.13 ppb)). The precision of BA, IA, and VA, if assessed in terms of relative standard error (RSE), maintained above 5%, while the precison of other compounds were below 5%. The reproducibility of analysis improved with the aid of internal standard calibration (PA: $1.1{\pm}0.4%$, BA: $10{\pm}0.46$, IA; $12{\pm}0.3%$, VA: $4{\pm}0.1%$), respectively. The results of this study showed that organic fatty acid can be analyzed using adsorption tube and thermal desorber in a more reliable way to replace alkali absorption method introduced in the odor prevention law of the Korea Ministry of Environment (KMOE).