• Title/Summary/Keyword: 충전액

Search Result 114, Processing Time 0.024 seconds

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF

Clinical Effect of Albumin Addition to the Prime solution in Cardiopulmonary Bypass (체외순환시 산화기 충전액에 첨가된 알부민의 임상적 효과)

  • Lee, Hyeong-Gyo;Yu, Se-Yeong
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1152-1157
    • /
    • 1990
  • Colloid solution is commonly used to increase the oncotic pressures of priming solutions used in the cardiopulmonary bypass circuit. To study the effectiveness of this practice, we retrospectively evaluated 24 patients undergoing cardiac operations to receive isoelectric solution plus 50 gm of albumin[group A], isoelectric solution plus 25 gm of albumin[group B] and isoelectric solution without albumin[group C] as the prime solution for the bypass circuit. Various clinical parameters related to the perioperative fluid balance, cardiopulmonary function, and renal function were studied. There were no differences between the three groups with regard to postoperative clinical parameter of cardiopulmonary, liver function and renal function. But at the previous report by Cho et al. [38], there was a significant difference between groups with regard to hematologic property, especially in crenated red blood cells. These hematologic events did not affect the clinical outcome but thorough evaluations are needed in order to prove the clinical effect of crenated red blood cell. We conclude that there is no clinically detectable advantage for the routinely supplementing of albumin to the priming solution of bypass circuit in cardiac operations. Whether this practice can be of value in selected cases needs to be further studied.

  • PDF

Clinical Study of the Effect of Aprotinin for Hemostasis in Open Heart Surgery (개심술시 Aprotinin의 지혈효과에 관한 임상적 고찰)

  • 정성운;김종원
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.364-367
    • /
    • 1999
  • Background: The efficacy of the hemostasis of prophylactic aprotinin after cardiac valve replacement was evaluated from January 1994 to December 1996 at Pusan National University Hospital. Material and Method: In a randomized study, 20 patients received aprotinin(2${\times}$106 KIU as a loading dose for 30 minutes after anesthesia, 1${\times}$106 KIU for priming and 5${\times}$105 KIU/hr as a maintenance dose from the completion of loading dose till skin closure) and another 20 untreated patients served as controls. Result: Aprotinin produced a significant reduction in postoperative blood loss compared with controls and significantly decreased total exposure to allogenic blood products compared with the control group(p<0.05). Conclusion: We conclude that aprotinin effectively reduces postoperative blood loss and trasfusion in patient undergoing cardiac valve replacement.

  • PDF

Microleakage Assessment of a Pozzolan Cement-based Mineral Trioxide Aggregate Root Canal Sealer (포졸란 시멘트를 기반으로 하는 근관전색제의 치근단부 미세누출 평가)

  • Kim, Mijun;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • This study aimed to assess microleakage of Endoseal MTA when it is used as a root canal sealer and a root canal filling material compared with conventional endodontic treatment materials Forty-two mature human permanent teeth with a single root canal were divided randomly into three experimental groups (n = 10) and two control groups (n = 6). Group A was obturated with AH $plus^{(R)}$ and gutta-percha (GP). Group E1 was obturated with Endoseal MTA and GP. Group E2 was obturated with Endoseal MTA only. The positive control group was obturated with GP only and the negative control group was obturated in the same way as the experimental groups. The samples were kept in saline solution for 24 hours and were immersed in 0.2% rhodamine B dye solution for 24 hours. Then the samples were split longitudinally and the micoleakage was assessed under a stereomicroscope. Complete microleakage was detected in all positive control group samples, whereas no microleakage was detected in the negative control group. There was no statistically significant difference between the experimental groups in the Kruskal-Wallis test. These results suggest that Endoseal MTA has potential use as a root canal sealer and a root canal filling material.

A Study on Biogas Production from Low Rank Coal in a Column Experiment (저품위 석탄을 충전한 칼럼실험에서의 바이오가스 생산에 관한 연구)

  • Yoon, Seok-Pyo;Lim, Hak-Sang;Yun, Yeo-Myeong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.1
    • /
    • pp.57-65
    • /
    • 2017
  • In a column experiment with low rank coal, rice straw was additionally supplied to induce methane gas generation by microorganisms in the state of supplying microorganisms and nutrients, and long-term biogas production characteristics were observed. When the weight ratio of the rice straw to coal was 0.04 or less, there was no significant gas generation. At 0.08, the biogas was generated for about 90 days. However, the methane gas generation was only 5% compared with the vial test result at optimum condition. Therefore, in order to produce biogas in the coal deposit in situ, a reactor that operates at COD concentration of 2000 mg/L or more at a ratio of 1:3 or more of rice straw to coal should be installed on the ground or under the ground. Liquid from the column filled with coal and rice straw and a liquid from vial containing rice straw were analyzed by microbial community analysis using pyrosequencing method, and compared the dominant microbial species among the two samples. In terms of the uniformity and diversity of the bacteria, the coal-filled column showed various species distribution, which has shown to be a disadvantageous microbial distribution to methane production.

Modeling of the Charge-discharge Behavior of a 12-V Automotive Lead-acid Battery (차량용 12-V 납축전지의 충·방전 모델링)

  • Kim, Ui Seong;Jeon, Sehoon;Jeon, Wonjin;Shin, Chee Burm;Chung, Seung Myun;Kim, Sung Tae
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.242-248
    • /
    • 2007
  • For an optimal design of automotive electric system, it is important to have a reliable modeling tool to predict the charge-discharge behaviors of the automotive battery. In this work, a two-dimensional modeling was carried out to predict the charge-discharge behaviors of a 12-V automotive lead-acid battery. The model accounted for electrochemical kinetics and ionic mass transfer in a battery cell. In order to validate the modeling, modeling results were compared with the experimental data of the charge-discharge behaviors of a lead-acid battery. The discharge behaviors were measured with three different discharge rates of C/5, C/10, and C/20 at operating temperature of $25^{\circ}C$. The batteries were charged with constant current of 30A until the charging voltage reached to a predetermined value of 14.24 V and then the charging voltage was kept constant. The discharge and charge curves from the measurements and modeling were in good agreement. Based on the modeling, the distributions of the electrical potentials of the solid and solution phases, the porosity of the electrodes, and the current density within the electrodes as well as the acid concentration can be predicted as a function of charge and discharge time.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

Separation of Cations on the Hydrophobic Reagent Coated Column (Hydrophobic Reagent를 흡착시킨 분리관에서의 양이온 분리)

  • Tae Yoon Eom;Kih Soo Cho;Youn Doo Kim
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.328-333
    • /
    • 1987
  • 1-eicosylsulfate($C_{20}H_{41}SO_4^-$) was coated onto 5 ${\mu}m$ C18 reversed phase column. Adsorption equilibrium was reached when 1.2l of $1.46{\times}10^{-4}M$ in 25% acetonitrile solution passed through the column. This coated column proved to be stable up to 10l of 0.05 M ${\alpha}$-HiBA eluent used. The column efficiencies of Eu, Nd, Ce and La measured were about 0.04 mm of HETP using 0.15M ${\alpha}$-HiBA eluent at a flow rate of 1.0ml/min. This column was used to separate some lanthanides and transition metal ions, andmshowed an excellent resolution, respectively.

  • PDF

Extraction and Separation of Protein-bound Polysaccharide by Lentinus edodes (표고버섯 배양액으로부터 단백다당류의 추출 및 정제 방법)

  • 박경숙;이별나
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.4
    • /
    • pp.503-508
    • /
    • 1997
  • The extraction and separation methods of protein-bound polysaccharides from the mycelium and culture broth of L. edodes were investigated. The use 2% solution of surface active agent, Triton X-100 was effective for extraction of the protein-bound polysaccharide from the mycelium. The extraction of the protein-bound polysaccharides from mycelium with hot water was achieved by 4 hours extraction at 10$0^{\circ}C$. For the separation and partial purification of the protein bound polysaccharides the column chromatography using DEAE-Cellulose, DEAE-Sephadex and Sephadex proved to be effective.

  • PDF

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF