• 제목/요약/키워드: 충격진동

검색결과 1,213건 처리시간 0.026초

센서 동역학을 고려한 충격응답해석 (Analysis of Impact Responses Considering Sensor Dynamics)

  • B. J. Ryu;K. Y. Ahn;B. H. Kwon;I. S. Oh;Lee, G. S.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.373.1-373
    • /
    • 2002
  • Impact is the most common type of dynamic loading conditions that give rise to impulsive forces and affects the vibrational characteristics of mechanical systems. Since the impact force and response are measured indirectly through the sensors, it is difficult to predict the impact force and acceleration. In this study, contact force model based on the Hertz law is proposed in order to predict the impact force correctly. (omitted)

  • PDF

함정 탑재 장비의 내충격 성능 평가

  • 정정훈
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.21-28
    • /
    • 1998
  • 본 고에서는 미해군을 비롯한 유럽의 선진 군사 강국들이 현재 사용하고 있는 함정용 탑재 장비의 내충격 성능 평가 방법을 살펴보고, 동 기술 개발 분야에 대한 국내의 현황및 향후 기술개발에 대한 국내의 현황및 향후 기술개발 방향에 대해 개괄하고자 한다.

  • PDF

비평형 응축이 충격파 진동에 미치는 영향에 관한 수치 해석적 연구 (A Numerical Study of the Effect of Non-equilibrium Condensation on the Oscillation of Shock Wave in a Transonic Airfoil Flow)

  • 전흥균;김인원;권영두;권순범
    • 대한기계학회논문집B
    • /
    • 제38권3호
    • /
    • pp.219-225
    • /
    • 2014
  • 본 연구에서는 NACA0012/14/15 천음속 에어포일 유동에서 비평형 응축이 충격파 진동에 미치는 영향을 TVD 수치해석을 통하여 연구하였다. 주류 마하수 0.81-0.90에 대해, 정체점 상대습도 및 에어포일의 기하학적 형상이 유동 특성에 미치는 영향이 구명되었다. 받음각 ${\alpha}=0^{\circ}$, 정체점 온도(288K) 및 주류 마하수가 0.87인 경우, 정체점 상대습도의 증가는 Terminating Shock의 충격파 강도를 약화시킨다. 정체점 상대습도가 30%인 경우 961Hz이던 충격파의 진동수가 60%일 때는 912Hz로 약 5% 감소한다. 정체점 상대습도가 동일한 경우는 주류 마하수가 클수록 충격파의 진동수 및 이동거리는 크게 된다. 또, 진동의 한 주기에 대해 항력계수의 변화도 구명되었다. 정체점 상대습도가 높을수록 최대 항력 계수는 작고, 항력계수의 변화폭 또한 감소한다. 한편 에어포일의 최대 두께가 두꺼울수록 초음속 영역의 크기는 증가하며 충격파의 진동수 및 이동거리도 증가한다.

바닥충격음 완충재의 동적특성과 소음저감 성능 비교 (Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad)

  • 양수영;이동훈;홍병국;송화영;이주원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

유한 요소법을 이용한 나 슬래브의 2차원 바닥 충격진동 해석 (2-Dimensional Floor Impact Vibration Analysis in Bare Reinforced Concrete Slab Using Finite Element Method)

  • 서상호;전진용
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.604-611
    • /
    • 2005
  • The relationship between floor impact sound and vibration has been studied by field measurements, and the vibration modal characteristics have been analyzed. Vibration levels impacted by a standard heavy-weight impact source have been predicted according to the main design parameters using finite element method. Experimental results show that the dominant frequencies of the heavy impact sounds range below 100 Hz and that they are coincident with natural frequencies of the concrete slab. In addition, simple 2-dimensional finite element models are proposed to substitute 2 types of 3-dimensional models of complicated floor structural slabs those by The analytical result shows that the natural frequencies from first to fifth mode well correspond to those by experiments with an error of less than $12\%$, and acceleration peak value iscoincident with an error of less than $2\%$. Using the finite element model. vibration levels areestimated according to the design Parameters, slab thickness, compressive strength, and as a result, the thickness is revealed as effective to increase natural frequencies by $20\~30\%$ and to reduce the vibration level by 3$\~$4 dB per 30 mm of extra thickness.

압전식 충격파 체외 쇄석기 사용시 초점위치에 의한 대상물의 진동과 파쇄효율과의 상관성 (The Relativity between Vibration of Phantom and Its Break Efficiency Due to Position of Focus Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter)

  • 장윤석
    • 한국음향학회지
    • /
    • 제19권5호
    • /
    • pp.35-40
    • /
    • 2000
  • 본 연구에서는 먼저 압전형 쇄석기에 의한 충격파 조사시에 발생하는 파쇄대상물의 진동과 그 때 들려오는 방사음과의 관계에 대하여 검토한다. 다음에 대상물에 있어서의 초점위치와 고유진동과의 관계에 대해서도 조사한 결과를 제시한다. 아울러 동일한 실험을 파쇄가능한 대상물에 시행하여 대상물의 진동과 그 파쇄효율과의 관계에 대해서도 실험적으로 검토한다. 그 결과, 초점위치에 따른 대상물 고유진동의 피크 주파수 파워와 파쇄효율과의 상관성을 명확히 확인할 수 있었다.

  • PDF

경사충격파 박리유동 제어를 위한 초음속 진동제트 분출위치의 영향성 연구 (A Study of the Influence of the Injection Location of Supersonic Sweeping Jet for the Control of Shock-Induced Separation)

  • 박상훈;이열
    • 한국항공우주학회지
    • /
    • 제50권11호
    • /
    • pp.747-754
    • /
    • 2022
  • 유체진동기에서 분출되는 초음속 진동제트를 이용하여 충격파에 의한 경계층 박리유동을 제어하는 실험적 연구가 이루어졌다. 유체진동기의 위치와 제어압력의 변화가 경사충격파에 의하여 발생되는 경계층 박리유동의 특성에 미치는 영향이 관찰되었고, 이를 위하여 고속 슐리렌, 표면유동가시화, 벽압력 측정, 그리고 정밀 피토관 측정 기법이 적용되었다. 본 연구의 초음속 진동제트의 박리유동 제어 특성은 공기제트 와류를 이용한 기존 제어기법과 정량적으로 비교 분석되었다.