• Title/Summary/Keyword: 출력계수

Search Result 667, Processing Time 0.025 seconds

A Design of Output Voltage Compensation Circuits for Bipolar Integrated Pressure Sensor (바이폴라 공정을 이용한 압력센서용 출력전압 보상회로의 설계)

  • Lee, Bo-Na;Kim, Kun-Nyun;Park, Hyo-Derk
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.300-305
    • /
    • 1998
  • In this paper, integrated pressure sensor with calibration of offset voltage and full scale output and temperature compensation of offset voltage and full scale output were designed. The signal conditioning circuitry are designed that calibrate the offset voltage and full scale output to desired values and minimize the temperature drift of offset voltage and full scale output. Designed circuits are simulated using SPICE in a bipolar technology. The ion implanted resistor of different temperature coefficient were used to trimming the desired values. As a results, offset voltage was calibrated to 0.133V and the temperature drift of offset voltage was reduced to $42\;ppm/^{\circ}C$. Also, the full scale output was calibrated to 4.65V and the temperature coefficient of full scale output was reduced to $40ppm/^{\circ}C$ after temperature compensation.

  • PDF

Geometry Design of a Pitch Controlling Type Horizontal Axis Turbine and Comparison of Power Coefficients (피치각 제어형 수평축 조류 터빈의 형상설계 및 출력계수 비교)

  • Park, Hoon Cheol;Truong, Quang-Tri;Phan, Le-Quang;Ko, Jin Hwan;Lee, Kwang-Soo;Le, Tuyen Quang;Kang, Taesam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.167-173
    • /
    • 2014
  • In this work, based on the blade element-momentum theory (BEMT), we proposed the geometry of a lab-scale horizontal axis tidal turbine with a diameter of 80cm, which can demonstrate the maximum power coefficient, and investigated the effect of blade pitch angle increase on the power coefficient. For validation of the computed power coefficients by the BEMT, we also computed the power coefficient using the computational fluid dynamics (CFD) for each case. For the CFD, 15 times of the turbine radius was used for the length and diameter of the computational domain, and the open boundary condition was prescribed at the boundary of the computational domain. The maximum power coefficients of the turbine acquired by the BEMT and CFD were about 48%, showing a good agreement. Both of the power coefficients computed by the BEMT and CFD tended to decrease when the blade pitch angle increases. The two power coefficients for a given tip-speed ratio were in good agreement. Through the present study, we have confirmed that we can trust the proposed geometry and the computed power coefficients based on the BEMT.

소형 동력로의 무붕산 노심 설계

  • 최유선;김명현;박군철;이은철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.17-22
    • /
    • 1995
  • 열출력 108㎿$_{t}$급의 소형 원자로를 설계하였다. 설계 제한 조건으로 2년의 재장전 주기, 무붕산 노심, 저 출력 밀도를 채택하였고, 핵연료 집합체의 설계는 울진 304호기의 사양을 그대로 사용하였다. 노심 출력 준위 제어는 제어봉만으로 가능하도록 하였다. CASMO-3와 KINS-3를 통해 설계된 노심의 주기 길이 만족 여부 확인, 첨두 계수, 감속재 온도 계수, 출력 계수 등을 계산하였다. 설계 결과, 한국 표준 원전 핵연료집합체 사양으로 저출력 밀도의 소형인자로를 무붕산 운전으로 가정하여 설계 가능함을 알 수 있었으며, 감속재 온도 계수가 음의 안전성을 갖고 있으며, 가연성 독봉의 축방향 Zoning이 필요하며, 기존 상용로의 경우 보다 독봉을 많이 사용되어야 하며, 제어봉이 서양 장기판처럼 배치될 정도로 많이 사용되어야 함을 알았다.

  • PDF

Counterplan of Output Voltage Variation in accordance with Coupling Coefficient Increase for LCCL-S Compensation Network IPT System (LCCL-S 보상 네트워크를 적용한 IPT 시스템의 결합 계수 증가에 따른 출력 전압 대응 방안)

  • Kim, Min-Kook;Joo, Dong-Myoung;Woo, Dong-Gyun;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.1-2
    • /
    • 2015
  • 본 논문에서는 LCCL-S 보상 네트워크를 적용한 IPT 시스템의 결합 계수 증가에 따른 출력 전압 대응 방안에 대하여 비교 분석한다. LCCL-S 보상 네트워크는 정전압 출력 특성을 나타내며 출력 부하 범위에서 주파수 가변 범위가 작고, 상대적으로 bifurcation에서 자유로운 장점을 가진다. 하지만 결합 계수가 증가함에 따라 출력 전압이 지나치게 증가할 수 있다. 출력 전압 증가 문제 해결을 위하여 본 논문에서는, 고정격 소자를 이용하는 방법과 위상천이 기법을 활용하는 방법을 제시하고 이를 시뮬레이션을 통해 검증한다.

  • PDF

Measurement of Gain Coefficient and Saturation Power of CW Waveguide CO_2$$ Laser (연속발진 도파형 이산화탄소 레이저의 이득계수 및 포화출력 측정)

  • 이승걸;김현태;박대윤
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.162-168
    • /
    • 1990
  • Two ZnSe loss plates were installed in the resonator of waveguide CO2 laser which consisted of Pyrex capillary tube in order to change the internal loss. By rotating the loss plates, the output variations with the internalloss was measured on various discharge conditions. The variations could be explained by the Rigrod theory. and the saturation power and the unsaturated gain coefficient were determined by fitting of the experimental results. It was found that the saturation power increased while the unsaturated gain coefficient reduced as the discharge current or the gas flow rate increased.reased.

  • PDF

Development of Axial Power Distribution Monitoring System Using Two-Level Encore Detector (상하부 2개의 노외계측기를 이용한 축방향 출력분포 감시계통 개발)

  • Chi, Sung-Goo;Song, Jae-Woong;Ahn, Dwak-Hwan;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.294-301
    • /
    • 1989
  • The Axial Power Distribution Monitoring System(APDMS) program was developed to calculate a detailed axial power distribution using two-level excore detector, cold leg temperature and control rod position signals. The unnormalized two-level excore detector signals were corrected for the rod shadowing factor determined by control rod position and for the temperature shadowing factor calculated based on cold leg temperature. A shape annealing matrix was then applied to the corrected excore detector response to yield peripheral power. After the core average power was obtained using linear relationship bet-ween core average and peripheral power, the boundary point power correction coefficient was applied to core average power in order to obtain boundary power for both upper and lower core axial boundaries. Then, the axial power distribution was synthesized by spline approximation. In spite of burnup, power level, control rod postion and axial offset changes, the comparisons of axial power distributions between BOXER simulation program and APDMS results showed good agreements within 5% root mean square error for Kori Unit 3 Cycle 4.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF

An Improved Maximum Power Point Tracking Method for a Grid-Connected Wind Power System (계통연계형 풍력 발전 시스템의 향상된 최대전력점 추종기법)

  • Kang, Yi-Kyu;Ro, Hak-Sueng;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.265-266
    • /
    • 2011
  • 본 논문은 승압형 컨버터를 이용한 계통연계형 풍력 발전시스템의 향상된 최대전력점 추종 기법을 제안한다. 풍력 발전시스템에서 블레이드 모델 기반의 출력계수 곡선을 추종하도록 운전할 때, 불완전한 데이터 입력 및 제어변수의 변동으로 최대출력점 추종 성능이 떨어지는 문제가 발생한다. 제안하는 제어기법은 출력계수곡선 추종제어 기법에 히스테리시스 제어를 결합하여 빠른 최대출력점 추종 특성을 가지고, 시스템 제어변수 오차에 의해 이탈된 운전점을 정정하여 정상상태의 출력효율을 향상시킨다. 2.7kW급 풍력발전 시스템 모델 기반의 시뮬레이션 결과를 통해 제안하는 제어기법의 우수성을 보인다.

  • PDF

고리 3호기 7주기 운전자료 분석

  • 김재학;이창호;송재웅
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.149-159
    • /
    • 1994
  • 노심설계의 검증을 통하여 설계의 신뢰성을 확인하며 이는 발전소 운전의 안전성과 경제성을 향상시킬 수 있는 발판이 된다. 본 보고서는 국산핵연료를 장전한 고리 3호기 7주기의 운전자료 중에서 핵설계와 관련한 인자의 측정치를 설계치와 비교 분석하고 평가하였다. 비교대상이 된 핵특성인자는 반응도 관련 자료인 임계붕소농도, 제어봉가, 등온온도계수 및 감속재온도계수등이고 출력분포 관련자료인 핵반응률 분포, 집합체 출력분포, 반경방향 첨두출력 F$\Delta$H/$^{N}$ , 축방향 출력분포, 축방향 첨두출력 Fq(z)및 노심 평균 축방향 출력편차(AO)등이다. 이들 인자들에 대한 설계치는 측정치와 잘 일치하였으며, 모두 안전성 관련 제한치이내로 만족함을 확인하였다. 또한 이러한 비교 분석을 통하여 후속주기의 핵설계에 운전자료를 반영할 수 있는 근거를 마련하였다.

  • PDF