Development of 119 Integrated Emergency Management System Training Simulator System (119 긴급구조시스템 교육훈련 시뮬레이터 개발)

  • Chung, Byung-Ho;Shin, Jae-Hong;Cho, Ung-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.461-467
    • /
    • 2015
  • 119 Integrated Emergency Management System, 119 IEMS hereinafter, is specialized command and control system for fire H.Q., that supports effective response activity at Fire, Rescue, and First Aids; it covers the emergency call taking, dispatch command delivery and situation control after dispatch command. While the efficiency of emergency response activity of call-taker and dispatcher is directly linked to the capability of qualified response in protecting the life and properties at real-time emergency condition, there is not any similar simulator system that can be used for training purposes for newly allocated personnel or beginner of emergency call taking and dispatch activity - 119 IEMS in fire H.Q. is the operation system that cannot be shared with other purposes, and they're highly expensive ICT system and infrastructure to be used as training and education. 119 Integrated Emergency Management Simulator System, 119 IEMS Simulator, was developed to be utilized in low cost for the training of 119 emergency call taker and dispatcher, and it can be used in training of various types of disaster and emergency handling, spans to emergency call taking, dispatch command, and field report and situation control after dispatch command.

A Study of Methodology Based on Role-Based Serucity Agent Medical Information System Security Architecture Design (보안 에이전트 역할 기반에 기초한 의료정보시스템 소프트웨어 보안아키텍쳐 설계방안)

  • Lee, Dae-Sung;Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.11 no.4
    • /
    • pp.77-83
    • /
    • 2011
  • In addition to the rapid development of health information technology services for the development of new medical information, a lot of research is underway. Improve health care services for patients are many ways to help them. However, no information about the security, if only the technology advances in health care systems will create an element of risk and threat. Today's issues and access issues are stable over a public network. Ad hocsensor network using secure, non-integrated health information system's security vulnerabilities does not solve the security vulnerabilities. In the development and utilization of health information systems to be subject to greater restrictions. Different security policies in an environment with a medical information system security policy mechanism that can be resolved if people get here are needed. Context-aware and flexible policy of integration and confidential medical information through the resistance should be guaranteed. Other cross-domain access control policy for telecommunications should be protected. In this paper, that the caller's medical information system, diversification, diversification Security agent in the environment, architecture, design, plan, role-based security system are proposed. The proposed system architecture, design work in the field and in the utilization of one model are expected to be.

A Study on the Improvement of Field Activity for Firemen in Sandwich Panel Warehouse (샌드위치패널 창고 소방대원 현장활동 대응력 제고 방안)

  • An, Byung-Kug;Kim, Woon-Hyung;Yang, So-Jin;Ham, En-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.421-429
    • /
    • 2020
  • Purpose: The purpose of this study is to present step-by-step countermeasures to prevent fires in sandwich panel warehouses and to enhance on-site fire response capabilities. Method: Interviews of firefighters related to fire sites, advice from fire experts, and experiments on protection performance were conducted to draw up measures for each element to strengthen on-site response capabilities. Result: The fire safety management checklist for warehouse fire safety managers and the installation standards for wall protection of sandwich panel warehouses are presented. In addition, Standard Operational Procedures(SOP) for fire application of sandwich panel warehouses were established for firefighters on-site. Conclusion: Through this study, step-by-step fire safety measures were established for preventing, protecting and suppressing fires in sandwich panel warehouses.

Development of the Disaster Medical Manual in Korea (국가재난의료매뉴얼의 개발)

  • Wang, Soon-Joo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • The disasters in Korea, such as the Sewol Ferry Ship sinking disaster has had problems related to the medical response system, with the problems of emergency medical support team in the site, the cooperation between medical staff and fire department officer at disaster site, field medical support and hospital acceptance of the wounded in trouble, the lack of specific systematic medical response manual. Therefore, from May 2014, when the disaster emergency information center in Central Emergency Medical Center starts, collection, modification and education of scattered preexisting disaster emergency medical manual had appeared as important issues. So, it was necessary to develop the early medical response system to disaster. The correction planning of disaster emergency medical response system by Central Emergency Medical Center included quick response system with the fast medical team operation, but the practical application was not enough. So the researcher and his team developed the first Korean disaster emergency medical response manual and the process of development was documented and arranged with the application by education and training.

A Study Symptoms by Types of Burn Patients in Pre-hospital Stage (병원 전 단계 화상환자의 유형별 징후에 관한 연구)

  • Park, SangKyu;Lee, JeongHyeok
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.95-104
    • /
    • 2015
  • The purpose of this study is to investigate differences in initial patient states based on types of burn accidents in the pre-hospital stage. 1,223 items of transfer data from burn accidents of Gyeonggi-do emergency medical services in 2013 were used. Burn accidents were most common in children younger than 10 years old (26.0%) and happened mostly at home (51.3%). Patient states by burn type were stable on average, but burns by electricity showed 10.7% of awareness condition U (Unresponsive), which was higher than that of the other burn types. Initial patient states for this type were shown to be serious, unlike other burn types, with temperatures of $35.90^{\circ}C$ and third degree burn depth (39.28%). Understanding initial patient states based on burn type is necessary in order to do effective approach in the pre-hospital stage.

Analysis of 119 dispatch for patients with cardio-cerebrovascular and respiratory diseases according to particulate matter (미세먼지 농도에 따른 심·뇌혈관계 및 호흡기계 환자의 119 구급 출동 분석)

  • Koo, Ji-Yeon;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.1
    • /
    • pp.37-55
    • /
    • 2020
  • Purpose: The purpose of this study was to provide basic data for improving the response capacity of 119 EMS systems by analyzing the effects of particulate matter on cardio-cerebrovascular and respiratory symptoms in the pre-hospital stage. Methods: We examined 46,389 patients who transferred to the hospital with complaints of cardiopulmonary arrest and cardio-cerebrovascular and respiratory symptoms by 119 ambulances in Incheon from 2016 to 2018. Results: The probability of 119 emergency dispatch for patients with cardiopulmonary arrest increased 2.8-4.0% from the day of symptom onset until two days before hospital presentation as particulate matter 10㎛ or less in diameter(PM10) increased by 10㎍/㎥ (OR=1.028; 95% CI=1.014-1.041, p=0.000, lag 0), (OR=1.040; 95% CI=1.024-1.056, p=0.000, lag 1), (OR=1.032; 95% CI=1.016-1.049, p=0.000, lag 2). Meanwhile, emergency dispatch increased 3.6-6.1% for PM2.5 in creased by 10㎍/㎥ (OR=1.046; 95% CI=1.024-1.068, p=0.000, lag 0), (OR=1.061; 95% CI=1.035-1.088, p=.000, lag 1), and (OR=1.036; 95% CI=1.010-1.063, p=0.006, lag 2). Conclusion: Emergency medical technicians (EMTs) who respond to 119 calls should rapidly and accurately evaluate patients and provide professional emergency care by identifying the characteristics of the vulnerable groups relative to particulate matter size. To prevent the occurrence and exacerbation of symptoms caused by particulate matter, EMTs should be prepared and equipped with a response system for high particulate matter in the EMS system.

Research on the Use of Rainwater During Fire Suppression (화재진압시 빗물이용에 관한 연구)

  • Gu, Dong-Uk;Shin, Ho-Joon;Back, Min-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.191-191
    • /
    • 2011
  • 최근 빗물이 우리가 앞으로 이용할 수 있는 수자원이라는 사회적인 인식의 변화와 함께 빗물이용이 더욱 요구되어졌다. 특히 빗물의 이용 저류 침투를 목적으로 하는 우수 관리에 대한 관심이 증가하면서 빗물이용시설의 설치, 운용의 필요성이 대두되고 있다. 이에 반해 화재발생은 해마다 증가하고 있으며, 화재 증가는 소방력 활동의 증가로 귀결되는데 현장활동 인력과 장비 그리고 화재를 진압하는데 사용되는 소방용수 증가를 의미한다. 따라서 본 연구는 빗물을 소방용수로 즉, 화재진압시 활용 가능성과 수자원 절약, 화재 사각지역 해소 측면을 살펴보기 위해서 통계분석, 현장조사, 기존 빗물이용시설 및 향후 완공 예정인 우수유출저감시설 활용과 소방용수 미설치 지역과 소방관서 옥상에 빗물이용시설 설치 방안을 제시하였으며, 그에 따른 공공서비스 확대와 경제성 분석을 통하여 다음과 같은 연구결과를 도출하였다. 첫째, 기존 빗물이용시설을 소방용수로 적극적으로 활용해야 한다. 빗물이용시설의 주 용도로 조경용수, 청소용수, 소방용수로 나눌 수 있는데 이수 측면에서 화재가 발생하지 않으면 소방용수로서 이용이 거의 없는 실정이다. 이는 해당 건물관계자나 소방대원들이 빗물이용시설을 인식을 못하고, 사용과 접근성 불편으로 상수도와 연결된 소화전에 의존하는 경우가 많다고 본다. 둘째, 상수도시설이 없는 지역은 빗물이용으로 소방용수를 확보해야 한다. 섬, 산간, 고지대, 농촌지역 등 상수도 서비스를 공급받지 못하는 지역은 화재발생시 수원확보곤란으로 인명과 재산피해의 증가요인으로 작용할 수 있다. 공공서비스 확대차원에서 화재 사각지역을 해소하기 위해 지붕면을 이용한 각 가정마다 또는 공동 빗물저장소와 지형의 비탈면을 이용한 빗물이용시설 설치로 소방용수 확보의 필요성을 확인했다. 셋째, 소방관서 신설시 빗물이용시설을 도입하여 설치한다. 화재통계와 현장조사를 통하여 소방차 출동대기부터 화재진압까지 많은 양의 물이 사용되는 것으로 파악되었다. 대부분 먹는 물 즉, 상수도를 이용한다는 점에서 수자원 절약과 화재진압에 사용된 물은 재생 불가능이라는 환경보전 측면에서 빗물이용으로 해답을 찾아본다. 따라서 빗물을 많이 저장할 수 있도록 옥상, 부지 등 집수면적을 확대하고 이에 적합한 저류시설을 갖춘 빗물이용시설을 설치한다. 끝으로 신속하고 효율적인 화재진압이 중요한 만큼 빗물을 소방용수로 활용하고자 할 때는 언제 어디에서나 현장 접근성, 사용 편리성, 충분한 수량을 고려해야한다.

  • PDF

Service Information System(SIS) with Real Time Using RFID and X-Internet in Ubiquitous Environments (유비쿼터스 환경에서 RFID와 X-Internet을 이용한 실시간 서비스 정보 시스템)

  • Jo Young-Ung;Lee Eung-Joo;Kim Dong-Kyu;Kwon Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1391-1402
    • /
    • 2005
  • All industrial Products of today are various demand of customers and are switchovered the manufacturing system of a small quantity batch production. Its life cycle was very shortened. An enterprise is improved to satisfaction with external customers and internal customers of infinity competition time. They can exist on achieving customer satisfaction management. In this paper, a new implementation of service information system (SIS) with real time using RFID and X-Internet in Ubiquitous environments is proposed. The proposed SIS system has Web architecture based on XML and has a new X-Internet environment overcoming limitation of Client/server architecture. The service information system analyze its material data and suppress the same CLAIM creation. The implementation method of real time SIS system using RFID and X-Internet is proposed for contribution of business market reducing F-Cost.

  • PDF

Study on Digital Investigation Model for Privacy Acts in Korea (개인정보보호법 기반 디지털 포렌식 수사 모델 연구)

  • Lee, Chang-Hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1212-1219
    • /
    • 2011
  • As recently Privacy Acts in Korea enforced in domestic companies' personal information management needs of a growing obligation for the safety measures and the right of personal information collection, use, limitations, management, and destroyed specifically for handling personal information. Such this regulations should be required technical and policy supports. Accordingly, for the enterprise incident has occurred, the personal information management system behave correctly operating to verify that the safety measures taken, and be determined by the specific preparation to be done. So the first, preparation phase corresponds to the upcoming digital forensic investigation model. On the other hand, the response team also carried these measures out correctly, it needs to be done to check the compliance of Privacy Act. Thus a digital forensics investigation model is strictly related with the implementation of the Privacy Acts and improve the coping strategies are needed. In this paper, we suggest a digital forensic investigation model corresponding to Privacy Act.

The Study for the Optimal Location of Fire Stations in Seoul (서울시의 소방서 최적입지에 관한 연구)

  • Kim, Geun-Young;Kang, Sung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.153-159
    • /
    • 2002
  • Disasters are the phenomena that we have to prevent the occurrence in order to keep the safety to human lives and properties, and if occurred, we have to minimize the economic, social, and mental costs of the occurred disasters or incidents. This research analyzes the optimal location of fire stations in terms of served population maximization in Seoul. This research introduces "the maximal covering location problem(MCLP)," one of the optimization techniques, as the primary research method. This research also applies a geographic information system into spatial distribution analyses of existing fire stations and observed fire incidents. Results from the analyses show that the existing location of fire stations and branches need to be improved. The dispatch location of fire engines should be reconsidered for rapid services of fire fighting.