• Title/Summary/Keyword: 축전지

Search Result 218, Processing Time 0.03 seconds

The Impact of Web Site Characteristics on e-Trust in Specialized Portal (전문포털의 웹사이트 특성이 e-신뢰에 미치는 영향)

  • Yoon Myeong-Sook;Kyung Jong-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.7
    • /
    • pp.1-12
    • /
    • 2006
  • This study examined relationship of effect between the characteristics of specialized portal and two branch dimension(cognitive and emotional e-trust) of e-trust on the specialized portal web-site. The characteristics of specialized portal web-site composed the guarantee factor, the structural factor, information factor, the entertainment factor and the flow factor by prior research. The model of e-trust strategy for specialized portal web-site is tested here using data from 122 samples. Result of factor and regression analysis show that the hypothesized relationships are significant. In examining the relationships of the factors in the study, the guarantee, structural and information fact effect on building of cognitive e-Trust. Second, the entertainment and flow factor effect on emotional e- Trust. Third, the cognitive and emotional e- Trust effect on the satisfaction of e-Service users. As these results, this study found out difference paths of e-Trust which effect on the satisfaction of e-Service by cognitive and emotional e- Trust approaches to the specialized portal web - sites.

  • PDF

The Surrealist Expression of Buddhist Symbolism Using 3D Computer Animation (3D 애니메이션을 이용한 불교 상징성의 초현실주의적 표현)

  • Lee, Hyun-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.93-101
    • /
    • 2014
  • My artwork, '1000 years', in the form of an animation film has been exhibited in the '2011 Haein Art project' of a special exhibition at the Haeinsa monastery compound. The '1000 years' represents the marvels of sacredness and Buddhist symbols using the surrealist expression of computer animation. This paper would argue how Buddhist idea can be explored by the surrealist expression of 3D computer animation. In the light of this, animation and surrealist expression will be reviewed by the epistemological approach and based on this, I would attempt to reveal how this computer animation film represents the meaning of Buddhist symbols which exist in the monastery compound. This research is processed by the case study related to my artwork as the form of art practice based research.

Effect of Airborne Lead Concentration Characterized by Size on Blood Lead and Their Relationships (납 흡수에 영향을 미치는 요인 분석: 납 크기 특성과 혈액중 납과의 관계)

  • Park, Dong-Uk;Ha, Kwon-Chul
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.316-321
    • /
    • 2005
  • 4개 업종(축전지제조업, 광명단 제조업, 2차 제련업, 라디에타 제조업)에서 근무하는 총 100명의 근로자를 대상으로 8단계다단충돌기(eight stages personal cascade imparter)에 의한 입자 크기 별 납농도를 측정하였다 크기 별 납 농도는 총납(PbA), 흡입성납(IPM-PbA), 흉곽성납(TPM-PbA), 호흡성납(RPM-PbA), $1{\mu}m$ 미만의 납$(Pb_{1\mu})$ 그리고 $1{\mu}m$ 이상의 소화성납$(Pb_{ing})$이었다. 동일한 근로자(100명)를 대상으로 혈액에서 납농도를 측정하였다. 혈액 중 납은 원자흡광광도계(atomic absorption spectrometry)의 Zeeman effect graphite furnace를 이용하여 분석하였다. 총 납의 노출농도는 노출기준$(50\;ug/m^3)$을 크게 초과하였다. 평균 호흡성 납 노출농도$(115.7\;ug/m^3)$ 총 납의 노출기준을 훨씬 초과하였다. $1{\mu}m$미만의 납$(Pb_{1\mu})$ 노출농도의 범위는 0.7에서 $(492.2\;ug/m^3)$이나 되었다. 근로자의 $46\%$가 혈액 중 납 농도 40 ug/dL을 초과하였다. 60 ug/dL을 초과한 경우도 $13\%$나 되었다. 입자 크기가 큰 납인 총납, 흡입성 납 그리고 호흡성 납 농도는 혈액 중 납 농도와 유의한 상관을 보였다(p<0.0001). 그러나 가장 높은 상관은 $1{\mu}m$미만의 납$(Pb_{1\mu})$ 혈액 중 납과의 관계였다. T-test에서 $50ug/m^3$이상의 호흡성 납을 나타낸 근로자 그룹과 $50ug/m^3$ 이하의 근로자 그룹간에의 혈액 중 납 농도는 유의한 차이가 있는 것으로 나타났다(p=0.000). 이러한 연구결과는 입자크기 구분이 없는 현재의 총납에 의한 노출기준과 측정방법은 미세 납 먼지에 노출되는 근로자의 납흡수를 보호하는데 한계점이 있다는 것을 의미한다. 향후 납 입자크기는 물론 근로자의 개인적인 위생과 작업내용 등을 변수로 납 흡수에 영향을 미치는 종합적인 요인을 찾아내는 연구를 진행할 필요가 있다.

A Study on the Preparation of Battery Separator for Polyethylene/Potassium Hexatitanate Whisker (폴리에틸렌/육티탄산칼륨 휘스커 복합재료에 의한 축전지격리막의 제조에 관한 연구)

  • Lee, Wan-Jin;Ko, Man-Seok;Choi, Byung-Ryul;Cho, Il-Hoon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.193-199
    • /
    • 1998
  • The mixtures of ultra-high molecular weight polythylene (UHMWPE), high density polyethylene (HDPE), process oil (mineral oil) and potassium hexatitanate whisker were melted and mixed at $150^{\circ}C$ for 30min, and prepared by compression molding to the specimen of separator of about $200{\mu}m$ thickness at the same temperature and 5000 psi. Thereafter the pores were formed by extracting process oil with organic solvents. In this study, the range of PR (the ratio polymer to process oil) was varied from 0.1 to 0.5 because the specimen turned into rubbery phase at which PR was below 0.1 whereas it changed into gel phase at which PR was above 0.5. When the specimen was treated with nonpolar organic solvents, process oil was extracted nearly 98%. Tensile strength was $31kg/cm^2$ at PR = 0.426, and resistance of specimen was $37m{\Omega}/cm^2$ at PR = 0.186, and $53m{\Omega}/cm^2$ at PR = 0.426. The $N_2$ adsorption-desorption isotherm showed a hysteresis representing regions of capillary condensation, and the surface area at PR = 0.186 was relatively large as $130cm^2/g$. Potassium hexatitanate whisker was randomly dispersed in between PE layers. It might be that the whisker is intercalated through the PE thin layers oriented by compression.

  • PDF

The Analysis of Composition and Characteristic in Olympics Cultural Program: Focusing on the 1988 Seoul Olympics and the 2018 PyeongChang Winter Olympic Games (올림픽 문화프로그램의 구성과 특성 분석 - 1988 서울올림픽과 2018 평창동계올림픽을 중심으로 -)

  • Lee, Ji-Yeon;Son, Jeung-Woo
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.4
    • /
    • pp.187-206
    • /
    • 2021
  • The purpose of this study is to analyze the compositions and characteristics in cultural programs of the 1988 Seoul Olympics and the 2018 PyeongChang Winter Olympic Games. A research method was considered the developmental aspects of Cultural Olympics in all-time Olympic Games and the cases of Cultural Olympics in a host country through a documentary research method. The compositions and characteristics in cultural programs of the 1988 Seoul Olympics and the 2018 PyeongChang Winter Olympic Games were diversely analyzed. The results are as follows. First, a concept of a cultural program was deepened and developed at the 1992 Barcelona Olympics. In the wake of the 2010 Vancouver Olympics, IOC published the Cultural Olympic Guide. Through the 2012 London Olympics, the Cultural Olympic Guide was revised. Second, the cultural programs of the 1988 Seoul Olympics and the 2018 PyeongChang Winter Olympic Games showed the characteristics of image change & status and of the international exchange strengthening in a host country and a holding city. Third, in terms of cultural programs, the 1988 Seoul Olympics comprised the celebrations, performances & exhibitions amid the Culture and Arts Festival, and the International Academic Conference. The 2018 PyeongChang Winter Olympic Games were composed of performances, exhibitions, festivals, humanities & experience, and educational events. Fourth, the 1988 Seoul Olympics included the key element of forming a program that equally has the characteristics with the harmony between tradition and modernity, with the promotion of the excellence in Korean traditional culture & the spread in a bond of sympathy, and with various cultures and arts in each region. Also, the 2018 PyeongChang Winter Olympic Games pushed ahead with the strategy dubbed 'The Olympics in which there is culture day after day, in which provincial residents participate, and in which the cultural heritage is left' in order to systematically expedite the cultural Olympics.

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF

A study on lead exposure indices of male workers exposed to lead less than 1 year in storage battery industries (축전지 제조업에서 입사 1년 미만 남자 사원들의 연 노출 지표치에 관한 연구)

  • HwangBo, Young;Kim, Yong-Bae;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.747-764
    • /
    • 1996
  • This study intended to obtain an useful information for health management of lead exposed workers and determine biological monitoring interval in early period of exposure by measuring the lead exposure indices and work duration in all male workers (n=433 persons) exposed less than 1 year in 6 storage battery industries and in 49 males who are not exposed to lead as control. The examined variables were blood lead concentration (PBB), Zinc-protoporphyrin concentration (ZPP), Hemoglobin (HB) and personal history; also measured lead concentration in air (PBA) in the workplace. According to the geometric mean of lead concentration in the air, the factories were grouped into three categories: A; When it is below $0.05mg/m^3$, B; When it is between 0.05 and $0.10mg/m^3$, and C; When it is above $0.10mg/m^3$. The results obtained were as follows: 1. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in all male workers exposed to lead less than 1 year in storage battery industries were $29.5{\pm}12.4{\mu}g/100ml,\;52.9{\pm}30.0{\mu}g/100ml\;and\;15.2{\pm}1.1\;gm/100ml$. 2. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in control group were $5.8{\pm}1.6{\mu}g/100ml,\;30.8{\pm}12.7{\mu}g/100ml\;and\;15.7{\pm}1.6{\mu}g/100ml$, being much lower than that of study group exposed to lead. 3. The means of blood lead concentration and ZPP concentration among group A were $21.9{\pm}7.6{\mu}g/100,\;41.4{\pm}12.6{\mu}g/100ml$ ; those of group B were $29.8{\pm}11.6{\mu}g/100,\;52.6{\pm}27.9{\mu}g/100ml$ ; those of group C were $37.2{\pm}13.5{\mu}g/100,\;66.3{\pm}40.7{\mu}g/100ml$. Significant differences were found among three factory group(P<0.01) that was classified by the geometric mean of lead concentration in the air, group A being the lowest. 4. The mean of blood lead concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $24.1{\pm}12.4{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $29.2{\pm}13.4{\mu}g/100ml$ ; and it was $28.9\sim34.5{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 5. The mean of ZPP concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $40.6{\pm}18.0{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $53.4{\pm}38.4{\mu}g/100ml$ ; and it was $51.5\sim60.4{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 6. Among total workers(433 person), 18.2% had PBB concentration higher than $40{\mu}g/100ml$ and 7.1% had ZPP concentration higher than $100{\mu}g/100ml$ ; In workers of factory group A, those were 0.9% and 0.0% ; In workers of factory group B, those were 17.1% and 6.9% ; In workers of factory group C, those were 39.4% and 15.4%. 7. The proportions of total workers(433 person) with blood lead concentration lower than $25{\mu}g/100ml$ and ZPP concentration lower than $50{\mu}g/100ml$ were 39.7% and 61.9%, respectively ; In workers of factory group A, those were 65.5% and 82.3% : In workers of factory group B, those were 36.1% and 60.2% ; In workers of factory group C, those were 19.2% and 43.3%. 8. Blood lead concentration (r=0.177, P<0.01), ZPP concentration (r=0.135, P<0.01), log ZPP (r=0.170, P<0.01) and hemoglobin (r=0.096, P<0.05) showed statistically significant correlation with work duration (month). ZPP concentration (r=0.612, P<0.01) and log ZPP (r=0.614, P<0.01) showed statistically significant correlation with blood lead concentration 9. The slopes of simple linear regression between work duration(month, independent variable) and blood lead concentration (dependent variable) in workplace with low air concentration of lead was less steeper than that of poor working condition with high geometric mean air concentration of lead. The study result indicates that new employees should be provided with biological monitoring including blood lead concentration test and education about personal hygiene and work place management within $3\sim4$ month.

  • PDF