Basic Experimental Properties of Concrete using Waste Concrete as Aggregate (骨材로써 廢콘크리트를 사용한 콘크리트의 基本的인 實驗 特性)

  • 구봉근;나재웅;신재인;박재성
    • Resources Recycling
    • /
    • v.10 no.1
    • /
    • pp.16-24
    • /
    • 2001
  • In this study, various mechanical properties of concretes employing waste concrete as aggregate were examined. These concretes were obtained by mixing seven types of aggregate for different ratios. So, the experimental variables are the kinds of aggregates (some different aggregate compositions) and W/C ratio (0.40, 0.45, 0.50). From experimental results, the reliable regression analysis equations between compressive strength and various experimental data for recycled aggregate concrete are presented. Consequently, this study was accomplished to investigate basic engineering properties of recycled aggregate concrete using waste concrete.

  • PDF

Optimum Mix Proportions of High Fluidity Antiwashout Underwater Concrete Using Ground Granulated Blast Furnace Slag (고로슬래그 미분말을 사용한 고유동 수중불분리성 콘크리트의 최적배합비 도출)

  • Kim, Sung-Wook;Park, Jung-Jun;Bae, Su-Ho;Park, Jae-Im
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3704-3712
    • /
    • 2012
  • Recently, antiwashout underwater concrete has been increasingly used for marine foundations of long span bridges. However, to shorten the construction period of antiwashout underwater concrete used in marine foundations, high fluidity antiwashout underwater concrete should be manufactured largely improving fluidity than the previous one. Thus, the objective of this experimental research is to suggest optimum mix proportions of high fluidity antiwashout underwater concrete. For this purpose, concrete specimens containing ground granulated blast furnace slag were manufactured according to the dosage of antiwashout admixture for unit binder contents of 550 and 600kg/$m^3$, respectively. And then, their quality performances such as slump flow, setting time, underwater segregation resistance, and ratio of compressive strength were evaluated according to the related specification of Korea Concrete Institute. It was observed from the test results that the minimum dosage of antiwashout admixture was necessary to satisfy the related specification.

A Study on the Properties of High-Fluidity Concrete with Low Binders Using Viscosity Agent (증점제를 사용한 저분체 고유동 콘크리트의 특성에 관한 연구)

  • Park, Gi-Joon;Park, Jung-Jun;Kim, Sung-Wook;Lee, Dong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.689-696
    • /
    • 2017
  • The practical applications of ordinary high-fluidity concrete have been limited due to several drawbacks, such as high hydration heat, high amount of shrinkage, and non-economic strength development. On the other hand, due to its advantages, such as improvement of construction quality, reduction of construction cost and period, the development of high-fluidity concrete is a pressing need. This study examined the properties of high-fluidity concrete, which can be manufactured on the low binders using a viscosity agent to prevent the segregation of materials. The optimal viscosity agent was selected by an evaluation of the mechanical properties of high-fluidity concrete among six viscosity agents. The acrylic type and urethane type viscosity agents showed the best performance within the range where no material separation occurred. The mechanical properties were evaluated to examine the optimal amount of AC and UT viscosity agent added by mixing two viscosity agents according to the adding ratio and blending them together with high performance water reducing agent. When the ratio of the AC : UT viscosity agents was 5:5, it was most suited for high-fluidity concrete with low binders by increasing the workability and effect of the reducing viscosity.

Mix Design of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트의 최적배합설계)

  • 손유신;이승훈;김규동;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.555-560
    • /
    • 2002
  • The structure of Chosun-ilbo Boopyung factory was desined as exposed concrete. The self compacting concrete(non-vibrating concrete) must be applied to this case because the exposed concrete wall is very thin(200mm) and high(6m), Laboratory tests and semi mock-up test were performed for optimum mix design of the self compacting concrete. As a result, the optimum mixes were observed at the 3-component types(ope, fly-ash, slag powder) that Vp$\geq$0.175, Vw/Vp$\geq$0.95, W=170~175$kgf/m^3$ and B=500~540$kgf/m^3$ Based on this result. we make plan that the pilot productions of batcher plant, the full-scale mock up tests and site application.

  • PDF

Optimum Mixture Proportion of Self-Compacting Concrete Considering Packing Factor of Aggregate and Fine Aggregate Volume Ratio (골재 채움율과 잔골재 용적비를 고려한 자기충전형 콘크리트의 최적배합)

  • 최연왕;정문영;정지승;문대중;안성일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.549-554
    • /
    • 2002
  • In Powder System, SCC demands high dosage of superplasticizer and a lage amout of powder for suitable fluidity and viscosity. Okamura's method of most representative mixing design method in SCC of Powder-System is unfavorable economically because of using a large amount of powder. In addition, many ready-mixed concrete plants do not use his mix design method and procedure due to complexity for practical application. Therefore, Nan Su proposed more simple mix design method than Okamura's. It had an advantage in simplicity in practical application and required a smaller amount of powders compared with Okamura's method. This paper proposed an optimal mixture proportion of SCC with consideration of Nan Su's method. The new and modified mix design method required a smaller amount of powder than that of Nan Su's. To check the properties of SCC, considered with the requirements specified by the Japanese Society of Civil Engineering.(JSCE)

  • PDF

Optimum Mix Design of Concrete(II) (콘크리트 용도별 최적배합을 위한 연구(II))

  • 심재원;이병덕;양우석;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.175-178
    • /
    • 1999
  • In most domestic construction fields, excessive cement content has been used because of stubborn official inspection. The purpose of this study is to reduce the cement content of mix proportioning for the decrease of hydration heat, brittleness and drying shrinkage which governs durability of concrete significantly. Parameters includes the compressive strengths, type and dosage rate of chemical and mineral admixtures and types of concrete. It is found that the chemical admixture is efficient to the reduction of cement content for high strength concrete (400kg/$\textrm{cm}^2$) and the effectiveness of mineral admixtures in the low strength concrete is somewhat higher than the high strength concrete.

  • PDF

Optimum Mix Design of Concrete (콘크리트 용도별 최적배합을 위한 연구)

  • 이병덕;양우석;안태성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.209-214
    • /
    • 1999
  • Strength provisions in Korea Concrete Institute code are more conservative that those in ACI code by increasing load factors and decreasing capacity reduction factors. Cement content of mix design in construction field is usually higher than the modified for standard deviation because of rigorous inspection. Higher cement content increases not only strengths but also heat of hydration, shrinkage and brittleness which are not beneficial. To reduce and optimize the cement content in current mix design of Korean Highway Corporation, properties of fresh and hardened concrete for 16 different mix proportions have been investigated. It is found that the chemical admixture and cement of current mix proportions for highway construction are somewhat higher than the optimum amount. Therefore, the optimum mix design for 16 different purposes has been proposed.

  • PDF

Optimum Technique for Concrete Mix-proportion Considering the Region Characteristics of Database (데이터베이스의 영역 특성을 고려한 콘크리트 최적 배합 선정 기법)

  • Lee, Bang-Yeon;Kim, Jae-Hong;Kim, Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.621-624
    • /
    • 2006
  • This paper presents a novel optimum technique for optimum mix-proportion using database-based prediction model of material properties for an object function or a constraint condition. The proposed technique provides high reliability of results introducing effective region model, which assesses whether the prediction model is effective or not, in optimization process. In order to validate the proposed technique, a genetic algorithm was adopted as a optimum technique, and an artificial neural network was adopted as a prediction model for material properties and as a model for assessing effective region. The mix-proportion obtained from the proposed technique is more reasonable than that obtained from a general optimum technique.

  • PDF

The Study on the Optimum Mix Design of the High-Strength Concrete in Site (고강도 콘크리트의 현장최적배합에 관한 연구)

  • Lee, Sang-Soo;Won, Cheol;Kim, Dong-Seok;Ahn, Jae-Hyun;Park, Chil-Lim
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.232-238
    • /
    • 1996
  • In this paper, the properties of high-strength concrete are described with respect to materials and mix conditions(water-cement ratio, chemical admixture, replacement of fly ash). As primary purposes of this study, the optimum mix design method of high-strength concrete to decrease unit cement contents is investigated, and the properties of fresh and hardened concretes are tested in terms of slump, air content and compressive strength. As results of this study, workability and strength development of the high-strength concrete depend on the water-cement ratio, replacement ratio of fly ash and dosage of the chemical admixture. The conditions which are proposed optimum mix design of the high-strength concrete show W/C 37%, S/A 42~45% and unit cement content 470~480kg/$\textrm{m}^3$. Based on the results, the applicability of high-strength concrete in site is clearly proved.

  • PDF

The Construction of High Strength Concrete (500kg/$\textrm{cm}^2$) with Fly-Ash for SAMSUNG APT in San Bon Area (산본 삼성고층 APT에 플라이 애쉬를 혼입한 500kg/$\textrm{cm}^2$이상의 고강도 콘크리트의 최적배합, 시공 및 구조적 연구)

  • 신성우;이광수;문정일;안종문;안경한;김현모;박희민;장일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.162-162
    • /
    • 1991
  • To investigate the properties of High Strength Concrete with Fly-Ash for SAMSUNG San Bon high rised apartment, following variables has been strudied and constructed, successfully. Major variables are F/(F+C), W/C, S/A, Pumping Method, etc.. The results show that 15% of F/(F+C) is the best properties for compressive strength of concrete, temperature reduction and workability.

  • PDF