회전축의 기동.정지시의 비틀림 진동제어 (Torsional Vibration Control of a Rotating Shaft in Starting and Stopping Process)

  • 김중배;이상조;박영필
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.459-467
    • /
    • 1992
  • 본 연구에서는 비틀림 진동계에 있어서의 비틀림 진동현상을 억제하도록 제어 하기 위하여 최적제어 이론에 기초한 모델추종법을 비틀림 진동계에 적용하였다. 디 지탈 컴퓨터에 의한 제어를 위하여 제어 알고리즘은 디지탈 설계로 되어 있다. 제어 는 각속도와 비틀림 진동제어의 양면으로 수행되며, 축의 각속도는 모델의 출력을 추 종하게 되며 이와 동시에 비틀림각도 감소하게 된다.

시뮬레이션 모델기반 냉난방 설비 일별 최적 기동/정지 제어기법 개발 (Development of Simulation Model Based Optimal Start and Stop Control Daily Strategy)

  • 이찬우;구준모
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.16-21
    • /
    • 2018
  • This work aims to develop a platform to investigate the effect of operation schedules on the building energy consumption and to derive a simulation model based optimal start and stop daily strategy. An open-source building energy simulation tool DOE2 is used for the engine, and the developed simulation model is validated using ASHRAE guideline 14. The effect of late-start/early-stop operation of HVAC system on the daily building energy consumption was analyzed using the developed simulation model. It was found that about 10% of energy consumption cut was possible using the control strategy for an hour of advance of the stop operation, and about 3% per an hour of delay of the start operation.

기동표적에 대한 입사각 정의와 입사각 제어 유도법칙 (Definition of Impact Angle and Impact Angle Control Law Against Maneuvering Target)

  • 김현승;박상섭;유창경
    • 한국항공우주학회지
    • /
    • 제43권8호
    • /
    • pp.669-676
    • /
    • 2015
  • 본 논문에서는 기동하는 표적에 대한 입사각 제어 유도법칙을 제안하였다. 제안된 유도법칙은 정지표적에 대한 최적입사각제어 유도법칙을 변형한 것으로서 기존의 PN(Proportional Navigation) 유도법칙에 입사각제어 항이 추가된 바이어스 PN 유도법칙의 형태를 갖는다. 시선각, 비행경로각, 그리고 표적에 대한 상대 비행경로각 관점에서의 세 가지 다른 종류의 입사각을 정의하였다. 다양한 공대공 교전 시나리오에 대한 수치 시뮬레이션을 통해 제안한 유도법칙의 성능을 검증하였다.

중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구 (A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System )

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

인공신경망 모델을 이용한 냉동기 및 공조기 최적 기동/정지 제어 (Artificial Neural Network Models for Optimal Start and Stop of Chiller and AHU)

  • 박성호;안기언;황승호;최선규;박철수
    • 대한건축학회논문집:구조계
    • /
    • 제35권2호
    • /
    • pp.45-52
    • /
    • 2019
  • BEMS(Building Energy Management Systems) have been applied to office buildings and collect relevant building energy data, e.g. temperatures, mass flow rates and energy consumptions of building mechanical systems and indoor spaces. The aforementioned measured data can be beneficially utilized for developing data-driven machine learning models which can be then used as part of MPC(Model Predictive Control) and/or optimal control strategies. In this study, the authors developed ANN(Artificial Neural Network) models of an AHU (Air Handling Unit) and a chiller for a real-life office building using BEMS data. Based on the ANN models, the authors developed optimal control strategies, e.g. daily operation schedule with regard to optimal start and stop of the AHU and the chiller (500 RT). It was found that due to the optimal start and stop of the AHU and the chiller, 4.5% and 16.4% of operation hours of the AHU and the chiller could be saved, compared to an existing operation.

가압 경수로(PWR)원전 CVCS 정화 탈염기의 $^{7}$ Li$_3$ 회수 운전 방안 운전 방안

  • 성기방
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.392-397
    • /
    • 1998
  • PWR 원전의 냉각재 화학 및 체적제어 계통(CVCS) 정화 탈염기는 핵연료에서 방출된 핵분열 생성물질과 방사성 부식생성물을 제거하여 계통 내 방사능 준위를 낮추고, 부식을 유발하는 불순물을 제거하여 계통의 건전성을 유지하며, pH 조절제인 리튬($^{7}$ Li$_3$)의 농도조절을 통해 냉각계 수화학 환경을 최적으로 유지시킨다. 이를 위해 CVCS에는 정화용 혼상 탈염기와 $^{7}$ Li$_3$ 조절용 양이온 탈염기가 설치되었으며, 각각의 탈염기는 독립적인 기능을 수행한다. 이는 원전 운전 중 중성자와 붕소($^{10}$ B$_{5}$ )의 핵반응으로 생성된 $^{7}$ Li$_3$3 의 회수가 불가능하기 때문에 정화 탈염기에는 값비싼 $^{7}$ Li$_3$ 포화형 수지를 충전하여야 한다. Pn 원전은 연료교체를 위해 주기적으로 연료계장전 기간을 갖으며 이에 따라 원자로 기동 수화학, 운전중 B/Li 농도조절에 의한 pH 화학, 원자로 정지화학 등의 주기적인 냉각재 수화학 관리를 해오고 있다. 본 연구에서는 효율적인 정화탈염기의 운영방안을 제시함으로 운전중 붕소의 핵분열로 생성되는 $^{7}$ Li$_3$ 의 회수가 가능하고 수지의 사용량 절감으로 수지폐기물 발생량 저감화를 이를 수 있을 것으로 기대된다.