• Title/Summary/Keyword: 최적환경조건

Search Result 1,416, Processing Time 0.028 seconds

A Study on Electrochemical Regeneration of Waste Iron-chloride Etchant and Copper Recovery (전기화학 반응에 의한 염화철 폐식각액의 재생 및 구리 회수에 관한 연구)

  • Kim, Seong-En;Lee, Sang-Lin;Kang, Sin-Choon;Kim, I-Cheol;Sheikh, Rizwan;Park, Yeung-Ho
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • Electrochemical regeneration of the iron chloride waste solution from PCB etching reduces environmental contamination and produces copper as by-product, so the economic feasibility is high. But iron chloride waste solution contains iron and copper and the reactions occurring in the electrolytic cell are complicated. In this work, the oxidation of iron chloride and copper deposition were examined through batch electrolysis and the optimum conditions of the process parameters were found. The oxidation of ferrous chloride was achieved easily to the desired level. The copper deposition efficiency was high in the reaction using the carbon cathode when the copper density was 12 g/L with the electric current density of $350mA/cm^2$, and the ratio of the $Fe^{2+}$ ion was high. In addition, the possibility of the scale-up was confirmed in continuous operation of bench reactor using the optimum conditions obtained.

Optimizing the bio-optical algorithm for quantifying Chlorophyll-a and Phycocyanin in inland water, Korea (대한민국 담수계의 클로로필a와 피코시아닌 정량화를 위한 분광알고리즘 최적화 연구)

  • Pyo, JongCheol;Pachepsky, Yakov;Lee, Hyuk;Park, Yongeun;Cho, Kyung Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.101-101
    • /
    • 2017
  • 근래에 대한민국 담수계에 조류 대발생으로 인한 수질악화 문재가 대두되고 있다. 또한 독성물질을 생성하는 남조류종이 우점하는 현상으로인해 수질문제와더불에 생태계와 인간의 건강도 잠재적인 위험을 받고있는 실정이다. 이와같은 조류 대발생으로인한 피해를 최소화하기위해 효과적인 수질관리가 필수적이다. 원격탐사기술은 조류의 공간적인 분포를 해석하고 농도를 정량화하기위해 이용되고 있다. 현재까지 많은 분광알고리즘들이 개발되어 담수유역에 적용이 되고 있다. 수체마다 다른 분광특성 때문에 알고리즘내의 파라미터 및 분광밴드 조정이 필수적이다. 하지만 대부분의 연구에선 파라미터와 밴드의 변경에 따른 결과향상에만 초점이 맞춰지고 있어 분광알고리즘내의 파라미터와 분광밴드사이의 관계 이해 뿐만아니라 알고리즘 최종 산출물에 대한 영향에 관한 설명이 전무한 실정이다. 본 연구에선, 대한민국 백제보를 대상으로 현장모니터링 및 조류추출 실험을 진행하였고, 이를 기반으로 5가지 클로로필a 알고리즘과 2가지 피코시아닌 알고리즘을 구축하였다. 알고리즘내에서 변수들의 관계와 영향을 알아보기위해 민감도 분석을 실시하였다. 민감도 분석 조건을 기반으로 one-objective 최적화 및 multi-objective 최적화를 실시하여 백제보수계를 대표할 수 있는 최적 변수들을 모의하였다. 민감도 분석결과 후방산란계수에 영향을 미치는 파라미터와 조류 생체량에 영향을 미치는 파라미터가 다른 변수들 및 알고리즘 농도산정결과에 가장 민감한 것으로 나타났다. multi-objective 최적화 결과가 one-objective 결과 및 reference 결과보다 대부분 정확도가 향상되었고 흡광도 계수를 함께 고려할 수 있기 때문에 백제보 수계의 분광특성을 함께 고려하여 대표할 수 있는 장점을 가지는 것으로 나타났다. 따라서, 본 연구는 민감도 분석을 활용하여 분광알고리즘 내의 변수들의 이해를 도모하였고, 최적화 기법 중, multi-objective 최적화 기법이 백제보의 분광특성을 대변하는 최적변수를 제시할 수 있음과 동시에 보다 나은 정확성을 제고할 수 있음을 확인하였다.

  • PDF

유류오염토양 세척유출수내 미세토사의 효율적 제거방안에 관한 연구

  • 윤세영;최상일;서용식;류두현;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.227-230
    • /
    • 2004
  • 본 연구에서는 유류오염토양 세척유출수내 미세토사의 효율적 제거를 위한 최적의 방안 및 적용 운전 조건을 도출하고자 하였다. 응집제를 주입하지 않은 blank 실험결과, 광운대학교 토양 세척유출수는 pH 7~12의 범위에서 65~75%의 효율을 나타내었고, 우이천 하천퇴적 토양 세척유출수는 pH 7~11의 범위에서 30% 안팎의, pH 12에서는 70% 정도의 낮은 효율을 나타내었다. pH 13에서는 두 가지 세척유출수에서 각각 91%, 85%의 효율을 나타내었다. 응집ㆍ침전 실험 결과, 광운대학교 토양 세척유출수는 FeC13, alum, PAC을 적용하였을 때 대체로 99% 이상의 효율을 보였으나, PAM을 적용하였을 때는 pH 13에서만 약 95%의 효율을 보였을 뿐 pH 7~12의 범위에서는 50~70%의 낮은 효율을 보였다. 우이천 하천퇴적 토양 세척유출수는 alum과 PAC을 적용하였을 때 대체로 90% 이상의 효율을 나타내었으나, FeC13와 PAM을 적용하였을 때는 pH 13일 경우에서만 98%이상의 효율을 보였을 뿐 다른 pH조건에서는 대체로 60%이하의 효율을 보였다. 두 가지 세척유출수에 대하여 높은 효율을 보인 alum과 PAC의 경제성을 비교해본 결과 같은 양의 세척유출수를 응집처리 할 경우 PAC에 비하여 alum을 적용하였을 때 적은 비용이 소요되었다. 따라서 alum이 효율성과 경제성에서 가장 우수함을 알 수 있었다.

  • PDF

Closed Drift Ion Source 설계를 위한 전극 구조와 자장세기에 따른 방전 특성 연구

  • Kim, Gi-Taek;Lee, Seung-Hun;Gang, Yong-Jin;Kim, Jong-Guk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.216.1-216.1
    • /
    • 2014
  • Closed drift ion source는 그 특성으로 인하여 강판 표면처리, 금속 표면 산화막 형성, 폴리머 혹은 기타 표면 개질 등 다양한 분야에서 사용이 되고 있다. 다양한 환경에서 사용 되는 소스의 특성으로 인하여 각기 다른 공정에 대한 최적의 특성이 요구 되며, 이러한 공정 환경에 맞춘 소스를 설계하기 위해서 ion source내 전극의 구조 및 자기장 세기 등 이온소스의 구조적 특성에 대한 연구가 필요하게 된다. 본 연구에서는 선형 이온소스의 구조 설계를 위한 실험을 소형(이온빔 인출 슬릿 직경: 60 mm) 이온빔 인출 장치를 제작하여 전극 구조에 따른 방전 특성을 우선적으로 평가를 실시하여 소형 이온빔 인출 장치에서 도출된 결과를 바탕으로 0.3 m급 linear closed drift ion source 설계에 대한 변수를 조사 하였다. 실험은 양극-음극(C-A) 간 간격 및 음극 슬릿(C-C) 간격 그리고 자기장 세기 조건에서 방전 전류 및 인출 이온빔 전류량 측정하였으며, 이 결과를 전산모사 결과와 비교 하였다. 방전전압 1~5 kV, 가스유량 10~50 sccm 조건에서 Ar 이온빔 방전 특성을 평가한 결과, 양극-음극(C-A) 간격이 넓을수록, 음극-음극(C-C) 간격이 좁을수록 방전 전류량이 증가함을 확인 하였다. 또한, 공정 가스 압력 및 자기장 세기 변화에 따른 1~5 kV의 방전 전압에 대한 방전 특성의 관찰 결과, 압력 및 자기장 변화에 따라서 방전 전류의 변화를 관찰 할 수 있었으며, 이에 대한 결과를 통하여 이온 소스 구조 내부에서의 방전 영역에 대한 압력과 자기장 세기에 대한 영향을 분석 할 수 있었다.

  • PDF

Optimal Design of Flow Measurement System Using Turbine Flowmeter (터빈유량계를 이용한 유량 측정 시스템의 최적 설계)

  • Kim, Hong-Tark;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.77-84
    • /
    • 2018
  • The turbine flowmeter is selected for high precision and reproducibility at the time of flow rate measurement but causes various uncertainty factors of measurement in the difference between the standard environmental condition at calibration and the environmental condition at the site. Also, a reliable interpolation method is required for use in sections other than calibrated measurement values. Therefore, in this paper, in order to improve the reliability of the flow rate measurement, we designed and manufactured a device that accurately measures the output signal of the turbine flowmeter, interpolates the value of the calibrated result value, and corrects the temperature change in real time We confirmed the reliability of the measurement at the site to carry out the performance verification.

Decision Algorithm of Natural Algae Coagulant Dose to Control Algae from the Influent of Water Works (정수장 유입조류 전처리를 위한 천연조류제거제(W.H.)의 최적주입농도 결정)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Yoon, Young H.;Ahn, Kwang-Ho;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.482-496
    • /
    • 2016
  • Algal blooms of cyanobacteria (blue-green Algae) due to the eutrophication of rivers and lakes can cause not only the damage by its biological toxins but also the economic loss in drinking water treatment. The natural algae coagulant, a commercial product known as W.H. containing the algicidal and allelopathic material derived from oak, can control algal problems proactively through the coagulation flotation process. However, because there have been no applications of the process for pre-treatment in drinking water plants, we could find no report on the optimum injection dose of W.H.. In this study, we have conducted several sets of jar-tests while changing W.H. dose and concentration of chl-a for (1) Han-river samples and (2) subcultured cyanobacteria samples, and monitored the removal mechanisms of algae intensively. Based on these jar-test results, two linear equations with variables of chl-a and turbidity have been deduced to predict the optimal W.H. dose after the multiple regression analysis using IBM-SPSS. Also, prototypes of automatic control logic have been suggested to inject the optimal W.H. dose promptly in response to the variation of water quality.

Removal of Color from a Biological Piggery Wastewater Treatment Effluent by Chemical Coagulation (화학적 응집을 이용한 생물학적 돈분폐수 처리수의 색도제거)

  • Park, Noh-Back;Seo, Tae-Kyeong;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1047-1053
    • /
    • 2008
  • This study was to evaluate the optimum conditions for chemical coagulation to remove color from the effluent of a piggery wastewater treatment process. The DOC concentration in the effluent was about 227.3 mg/L, color was 2,430 CU, turbidity was 22.1 NTU, and UV$_{254}$-absorbance was 3.7 cm$^{-1}$. The fractions of hydrophobic, transphilic, and hydrophilic substance of the effluent was about 55.3%, 17.4%, 27.3% respectively. Also, molecular weight cut-off(MWCO) of below 0.5 K, 0.5 K to 1 K, 1 K to 10 K, 10 K to 30 K, and over 30 K were 74.2%, 7.3%, 5.5%, 7.1%, and 5.9% respectively. SCD(streaming current Detector) was used to find out the optimum pH values and coagulant dosages. The optimum dosages and pH of Al$^{3+}$ were 5.84 mM and 5.3, while those of Fe$^{3+}$ were 9.25 mM and 5.0, respectively. At optimum conditions of coagulation, color removal efficiencies for aluminium sulfate and ferric chloride were as high as 91.9 and 98.7%, respectively. Chemical coagulation showed good performance to remove color from on biologically treated piggery wastewater.

Surrogate Models and Genetic Algorithm Application to Approximate Optimization of Discrete Design for A60 Class Deck Penetration Piece (A60 급 갑판 관통 관의 이산설계 근사최적화를 위한 대리모델과 유전자 알고리즘 응용)

  • Park, Woo Chang;Song, Chang Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.377-386
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistant system installed on a horizontal compartment to prevent flame spreading and protect lives in fire accidents in ships and offshore plants. This study deals with approximate optimization using discrete variables for the fire resistance design of an A60 class deck penetration piece using different surrogate models and a genetic algorithm. Transient heat transfer analysis was performed to evaluate the fire resistance design of the A60 class deck penetration piece. For the approximate optimization of the piece, the length, diameter, material type, and insulation density were applied to discrete design variables, and temperature, productivity, and cost constraints were considered. The approximate optimum design problem based on the surrogate models was formulated such that the discrete design variables were determined by minimizing the weight of the piece subjected to the constraints. The surrogate models used in the approximate optimization were the response surface model, Kriging model, and radial basis function-based neural network. The approximate optimization results were compared with the actual analysis results in terms of approximate accuracy. The radial basis function-based neural network showed the most accurate optimum design results for the fire resistance design of the A60 class deck penetration piece.

Quantification of Volatile Organic Compounds in Gas Sample Using Headspace Solid-Phase Microextraction (고상 미세 추출법을 이용한 가스시료 중 휘발성유기화합물의 정량 분석)

  • Kim, Jae Hyuck;Kim, Hyunook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.906-917
    • /
    • 2013
  • The purpose of this study is to quantify volatile organic compounds (VOCs) in gas sample using headspace solid-phase microextraction (HS-SPME) coupled to GC analysis. The optimal HS-SPME conditions was CAR/PDMS fiber and 30 min absorprion time for the analysis of various VOCs. In optimal conditions, 80 VOCs could be detected within 1 ppbv and even less than 0.0005 ppbv especially in the case of BTEX. However, fiber reproducibility on adsorption efficiency was 1~9.2% (between the same fiber) and 5.9~13.5% (between the other fiber). We successfully determined 35 VOCs in landfill gas with this method and found that VOCs of high concentration are emitting from vent pipe of closed/open landfill site under the HS-SPME conditions. This method may apply to VOCs/odor determination from various atmospheric environmental samples as well as landfills.

The Apparent Strains of Strain Gages in Cryogenic Environment (극저온 환경에서 스트레인 게이지의 겉보기 변형률 특성에 관한 연구)

  • 주진원;김갑순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1099-1107
    • /
    • 1992
  • The apparent strain of temperature self-compensated strain gages at cryogenic temperature is presented. By joining the international round robin test on electrical strain gages at cryogenic temperatures, apparent strain curves of up to the fourth order with respect to the temperature are obtained with different strain gages and different materials. The liquid nitrogen and the liquid helium are employed to get the cryogenic environment. The results can be effectively utilized to determine the real strains by mechanical loading at cryogenic temperature. This paper also describes the optimal selection of strain gages and test materials for the use of strain gages at cryogenic temperature.