• Title/Summary/Keyword: 최소침습술

Search Result 5, Processing Time 0.023 seconds

Development of Hip Joint Mechanical Stem for Minimally Invasive Surgery (최소침습술을 위한 고관절 메커니컬 스템의 개발)

  • Lee, Sunghyun;Bae, Ji-Yong;Jeon, Insu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.703-708
    • /
    • 2013
  • Conventional total hip joint replacement(THR) surgery requires a long incision and long rehabilitation time. The stem used in THR is inserted into the cancellous bone of the femur where it plays the role of the artificial joint. Minimally invasive surgery(MIS) has been devised to reduce muscle damage to patients. In this study, a mechanical stem was developed on the basis of MISto reduce the incision length through the principle of the gear. The mechanical stem consists of six components. A prototypical model for a mechanical stem was fabricated using an acryl-based polymer, and its workability was confirmed. To actualize the mechanical stem, a three-dimensional Bio-CAD modeling technique was applied. The hip joint area based on computed tomography(CT) was reconstructed. The safety of the mechanical stem by applying more load than the weight of a man under virtual surgery environment conditions was confirmed by finite element analysis.

Extracorporeal High Intensity Focused Ultrasound Therapy (체외강력집속초음파치료)

  • Han, Sang-Suk
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • Local treatment for tumors has developed from extended radical surgery to function preserving surgery on the basis of modern biology. With the development of minimally invasive technique, it changed to be minimal-invasive surgery. And nowadays technical revolution made non-invasive surgery possible with appearance of several kinds of non-surgical knives such as gamma knife, cyber knife, and HIFU (high intensity focused ultrasound) knife. In this article, history, HIFU machine and treatment procedure, histological change and its mechanism, clinical applications, advantage, disadvantage, and future prospect of extracorporeal high intensity focused ultrasound therapy using HIFU knife will be reviewed.

  • PDF

Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery (최소침습술을 위한 의료용 인스트루먼트의 동작 성능 향상)

  • Park, Hyeonjun;Won, Jongseok;Park, Jaeheung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1160-1166
    • /
    • 2013
  • This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.

5-D.O.F. Force/moment Sensor using Optical Intensity Modulation in MR-field (MR 환경에서 사용을 위한 5자유도 광학식 힘센서)

  • Kim, Min Gyu;Lee, Dong Hyeok;Cho, Nahm Gyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.520-528
    • /
    • 2013
  • A 20 mm diameter of small 5-D.O.F. force sensor has been developed for applications in MR-field Optical intensity modulation was adopted for transducing to miniaturize the sensor structure. For its accurate sensing of 5-D.O.F. force/moment, the elastic detecting module was designed to respond independently to each force or moment component. And for small size, two optical transducing modules of 2-D.O.F. and 3-D.O.F. were designed and integrated with the detecting module where optical fibers were arranged in parallel to make the sensor small. It is confirmed by calibration test that the detecting modules deforms linearly and independently to the input force. The results of evaluating test show that the range and resolution of forces are ${\pm}4$ N and 0.94~7.1 mN and the range and resolution of moments are ${\pm}120N{\cdot}mm$ and $0.023{\sim}0.034N{\cdot}mm$.

Evaluation of Thermoelectric Characteristics of Peltier Thermoelectric Module for Increasing Response Velocity in Shape Memory Alloy (SMA) Steering Catheter (형상기억합금(SMA) 스티어링 카테터의 반응속도 향상을 위한 펠티어 열전소자의 열전기적 특성 평가)

  • Oh, Dong-Joon;Kim, Cheol-Woong;Kim, Tae-Young;Lee, Ho-Sang;Kim, Jay-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.301-307
    • /
    • 2010
  • Actuation using a shape memory alloy (SMA) is considered to be an important technology that will play a leading role in market for next-generation medical devices because an SMA actuator can accurately imitate skillful and delicate hand movements. However, SMA actuators have not been successfully used because of problems in control design caused by the nonlinear hysteresis effect of SMA, which leads to inaccuracies in control systems. In order to overcome the effect, the authors invented a SMA actuator, which could actively and rapidly cool down and heat up, by combining a SMA catheter and a TE module using the Peltier effect. In order to evaluate the TE characteristics of our TE module system, the changes in the temperature with 1) incremental increases in a continuous electric current and 2) the appearance of a discontinuous constant or reverse current are discussed in this paper.