• Title/Summary/Keyword: 최소침습수술

Search Result 142, Processing Time 0.03 seconds

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Retrospective Evaluation of Implant Retained Overdentures Using Two Implants and Locator Attachments in the Edentulous Mandibles (Locator attachment를 이용한 하악 임플란트 유지 피개의치의 후향적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.153-162
    • /
    • 2013
  • This study compared the marginal bone loss around dental implants that were placed in the canine areas of the mandibles and finded the survival rate of the implants, marginal bone loss around implants and prosthetic complications in 20 patients treated with overdentures retained with Locator attachments. Implants placed in this study showed a 95% survival rate and the average marginal bone loss was 1.21 mm($SD{\pm}0.60mm$) in 94.3 weeks of functional loading. Implant-retained overdentures had various prosthetic complications such as male change, metal cap loosening, Locator attachment loosening, denture teeth change, relining and denture fracture. Implant-retained overdentures using two implants and Locator attachments in the edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.

The Early Experience with a Totally Laparoscopic Distal Gastrectomy (전(全)복강경하 원위부 위절제술의 초기 경험)

  • Kim Jin Jo;Song Gyo Young;Chin Hyung Min;Kim Wook;Jeon Hae Myoung;Park Cho Hyun;Park Seung Man;Lim Keun Woo;Park Woo Bae;Kim Seung Nam
    • Journal of Gastric Cancer
    • /
    • v.5 no.1
    • /
    • pp.16-22
    • /
    • 2005
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been increasing lately. Although minimally invasive surgery is more beneficial, no reported case of a totally laparoscopic distal gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experiences, to determine the feasibility of a totally laparoscopic distal gastrectomy using an intracorporeal gastroduodenostomy in treating early gastric carcinoma. Materials and Methods: We investigated surgical results and clinicopatholgic characteristics of eight(8) patients with an early gastric carcinoma who underwent a totally laparoscopic distal gastrectomy at the Department of Surgery, Our Lady of Mercy Hospital, The Catholic University of Korea, between June 2004 and September 2004. The intracorporeal gastroduodenostomy was performed with a delta-shaped ananstomosis by using only laparoscopic linear staplers (Endocutter 45mm; Ethicon Endosurgery, OH, USA). Results: The operative time was $369.4\pm62.5$ minutes (range $275\∼465$ minutes), and the anastomotic time was 45.1\pm14.4$ minutes (range $32\∼70$ minutes). The anastomotic time was shortened as surgical experience was gained. The number of laparoscopic linear staplers for an operation was $7.1\pm0.6$. The number of lymph nodes harvested was $31.9\pm13.1$. There was 1 case of transfusion and no case of conversion to an open procedure. The time to the first flatus was 2.8$\pm$0.5 days, and the time to the first food intake was $4.1\pm0.8$ days. There were no early postoperative complications, and the postoperative hospital stay was $10.0\pm3.9$ days. Conclusion: A totally laparoscopic distal gastrectomy using an intracorporeal gastroduodenostomy with a delta-shaped anastomosis is technically feasible and can maximize the benefit of laparoscopic surgery for early gastric cancer.

  • PDF

All-inside Arthroscopic Capsular Imbrication and Lateral Release in Patellofemoral Instability (Operative technique) (슬개대퇴관절 불안정성에서의 관절경적 All-inside 관절막 중첩술 및 외측 지대 유리술 (수술 술기))

  • Kim, Jae-Hwa;Cho, Duck-Yun;Yoon, Hyung-Ku;Kim, Jung-Ryul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.118-122
    • /
    • 2006
  • Purpose: We introduce a technique of all inside arthroscopic capsular imbrication and lateral release used to treat patellofemoral instability. Methods: With the arthroscope in the anteromedial portal for best viewing, the arthroscopic scissor is placed through superolateral portal for proximal to distal release. The release performed 5mm to 1cm from the edge of the patella. After completion of the procedure, with the arthroscope in anterolateral portal, we inserted 5mm cannula in superolateral portal and made working portal from superomedial portal. Medial reefing was performed with all inside technique by using curved needle of the spectrum suturing system and No. 1 monofilament PDS suture is passed through the superomedial portal percutaneously and retrieved through a superolateral portal. Conclusion: Several methods for arthroscopic patella realignment have been proposed, but they have consisted primarily of arthroscopically assisted techniques using a medial incision. We believe that our procedure is preferable to arthroscopically assisted methods commonly used, in that an incision is avoided and the vastus medialis obliqqus is not violated. Our technique is minimally invasive and is easy to control the tightness of the medial patellofemoral ligament (MPFL) under direct vision.

  • PDF

Arthroscopic Medial Plication using Pull-out Suture for the Treatment of Acute or Recurrent Patellar Dislocation - Technical Note - (급성 또는 재발성 슬개골 탈구의 치료에 있어서 견인 봉합술을 이용한 관절경적 내측 관절막 중첩술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Kim, Jae-Hoon;Ha, Hae-Chan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.214-218
    • /
    • 2006
  • Purpose: We describe a new technique of arthroscopic medial plication using pull-out suture with consideration of anatomical location of medial patellofemoral ligament for the treatment of acute or recurrent patellar dislocation. Operative technique: Under arthroscopic examination, sutures are passed through the medial capsule, at which medial patellofemoral ligament is located, from outside to inside of knee joint. Three guide wires are inserted from anterior surface of the patella to upper half of its medial border. Intraarticular portions of sutures are pulled out toward anterior surface of the patella through bony tunnels. Under appropriate tension, the sutures are tied after performing lateral retinacular release. Conclusion: As suturing medial patellofemoral ligament, this technique can maximize the effect of medial plication and can correct subluxation and tilt of the patella. It seems to be a minimally invasive, easy and effective method for the treatment of acute or recurrent patellar dislocation.

  • PDF

A Micro Finite Element Analysis on Effects of Altering Monomer-to-Powder ]Ratio of Bone Cement During Vertebroplasty (골 시멘트 중합 비율 변경이 척추성형술 치료에 미치는 영향에 대한 비교 분석)

  • 김형도;탁계래;김한성
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.451-458
    • /
    • 2002
  • Osteoporosis is a systemic skeletal disease caused by low bone mass and the decrease of bone density in the microstructure of trabecular bone. Drug therapy(PTH Parathyroid hormone) may increase the trabecular thickness and thus bone strength. Vertebroplasty is a minimally invasive surgery foy the treatment of osteoporotic vertebral compression fracture. This Procedure includes Puncturing vertebrae and filling with Polymethylmethacrylate(PMMA). Although altering recommended monomer-to-Powder ratio affects material properties of bone cement, clinicians commonly alter the mixture ratio to decrease viscosity and increase the working time. The Purposes of this study were to analyze the effect of 4he monomer-to-powder ratio on the mechanical characteristics of trabecular. In this paper, the finite element model of human vertebral trabecualr bone was developed by modified Voronoi diagram, to analyze the relative effect of hormone therapy and vertebroplasty at the treatment of osteoporotic vertebrae. Trabeuclar bone models for vertebroplasty with varied monomer-to-Powder ratio(0.40∼1.07 ㎖/g) were analyzed. Effective modulus and strength of bone cement-treated models were approximately 60% of those of intact models and these are almost twice the values of hormone-treated models. The bone cement models with the ratio of 0.53㎖/g have the maximum modulus and strength. For the ratio of 1.07㎖/g, the modulus and strength were minimum(42% and 49% respectively) but these were greater than those for drug therapy. This study shows that bone cement treatment is more effective than drug therapy. It is found that in vertebroplasty, using a monomer-to-powder ratio different from that recommended by manufacturer nay significantly not only reduce the cement's material Properties but also deteriorate the mechanical characteristics of osteoporotic vertebrae.

The Early Results of Endovenous Radiofrequency Ablation Using the 7 Fr. VNUS $ClosureFAST^{(R)}$ System in Varicose Veins (혈관 내 고주파열치료법인 7 Fr. VNUS $ClosureFAST^{(R)}$ System을 이용한 하지 정맥류 치료의 조기 결과)

  • Ryu, Sang-Woo;Oh, Hye-Ryung;Kim, Mi-Kyung;Moon, Seung-Ho;CheKar, Jay-Key;Yun, Ju-Sik;Hong, Seong-Beom
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.238-243
    • /
    • 2009
  • Background: Radiofrequency obliteration and endovenous laser therapy of the greater saphenous vein have recently been introduced as alternative, minimally invasive techniques for the treatment of saphenous vein incompetence. The 7 Fr. VNUS $ClosureFAST^{(R)}$ radiofrequency obliteration system was introduced in Gwang-Ju Veterans hospital. The purpose of this study is to evaluate the efficacy and complications of radiofrequency obliteration using the 7 Fr. VNUS $ClosureFAST^{(R)}$ system. Material and Method: Between May 2, 2007 and May 31, 2008, we performed radiofrequency obliteration on 90 patients. The number of males was 67 and their mean age was $57.9{\pm}11.0$ (range: $23{\sim}78$) years old. The patients underwent follow up exams at 3 weeks after the procedures and then every 3 months. The effects of treatment and the complications were reviewed. Result: The postoperative complications were ecchymosis (94.4%), pain (27.8%), paresthesia (25.6%), bullous formation (8.9%), edema (6.7%) and phlebitis (2.2%). One patient showed good blood flow after 3 weeks and one patient showed good blood flow after 3 months. The one-year success rate of radiofrequency obliteration in varicose veins was 97.6%. Conclusion: Our data showed acceptable operative results and short-term clinical results for treating varicose veins with radio frequency obliteration. Long-term follow-up and comparison of radio frequency obliteration with high ligation and stripping, previous radiofrequency ablation and endovenous laser therapy are needed in the future.

Conceptual framework for Emotions in Usability of Products (제품 사용성과 감성에 관한 개념적 연구)

  • Lee Kun-Pyo;Jeong Sang-Hoon
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2005
  • With the advent of computer technology, the fundamental nature of products has shaped from physical forms towards product interactivity, The focus is now on usability of the product with ease and efficiency rather than conversing with just the looks of the product. However, most definitions of usability and contemporary usability-related researches, have focused on the performance-oriented functional aspects of usability (i.e., how well users perform tasks using a product). Today, user expectations are higher; products that bring not only functional benefits but also emotional satisfaction. So far, there have been many studies on human emotions and the emotional side of products in the field of emotional engineering. Contemporary emotion-related researches have focused mainly on the relationship between product aesthetics and the emotional responses elicited by the products, but little is known about emotions elicited from using the products. The main objective of our research is analyzing user's emotional changes while using a product, to reveal the influence of usability on human emotions. In this research, we suggested conceptual framework for the study on the relationship between usability of products, and human emotions with emphasis on mobile phones. We also extracted emotional words for measuring user's emotions expressed not from looking at the product's appearance, but from using the product. First, we assembled a set of emotions that is sufficiently extensive to represent a general overview of the full repertoire of Korean emotions from the literature study. Secondly, we found emotional words in the after note by the users on the websites. Finally, verbal protocols in which the user says out loud what he/she ks feeling while he/she ks carrying out a task were collected. And then, the appropriateness of extracted emotional words was verified by the members of the consumer panel of a company through web survey. It is expected that emotional words extracted in this research will be used to measure user's emotional changes while using a product. Based on the conceptual framework suggested in this research, basic guidelines on interface design methods that reflect user's emotions will be illustrated.

  • PDF

Lung Biopsy after Localization of Pulmonary Nodules with Hook Wire (Hook Wire를 이용한 폐결절의 위치선정 및 생검)

  • Kim, Jin-Sik;Hwang, Jae-Joon;Lee, Song-Am;Lee, Woo-Surng;Kim, Yo-Han;Kim, Jun-Seok;Chee, Hyun-Keun;Yi, Jeong-Geun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.681-686
    • /
    • 2010
  • Background: A chest computed-tomography has become more prevalent so that it is more common to detect small sized pulmonary nodules that have not been found in previous simple chest x-ray. If those detected nodules are undersized or located in pulmonary parenchyma, it is difficult to accomplish a biopsy since it is vulnerable to explore them either grossly or digitally. Thus, in our hospital, a thoracoscopic pulmonary wedge resection was performed after locating a lesion by means of hook wire with CT-guided. Material and Method: 31 patients (17 males and 14 female patients) from December in 2006 to June in 2010 became our subjects; their 34 pulmonary nodules were subjected to the thoracoscopic pulmonary wedge resection after locating a lesion by means of hook wire with CT-guided. Also we analyzed a possibility of hook wire dislocation, a frequency of conversion to open thoracotomy, time consumed to operation after location of a lesion, operation time, post operation complication, and histological diagnosis of the lesion. Result: 12 of 34 cases were ground glass lesion, whereas 22 cases of them were solitary pulmonary lesion. The median value of the lesion was 8mm in size (range: 3 to 23 mm), while the median value was 12.5 mm in depth (range: 1 to 34 mm). The median value of time consumed from location of the lesion to anesthetic induction was 86.5 minutes (41~473 minutes); furthermore the mean value of operation time was 103 minutes (25~345 minutes). Intrathoracic wire dislocation was found in one case, but a target lesion was successfully excised. Open thoracotomy was performed in four cases due to pleural adhesion. However, there was no case of conversion to open thoracotomy due to failure to detect a target lesion. In histological diagnosis, metastatic cancer were found in 15 cases, which were the most common, primary lung cancer were in 9 cases, non-specific inflammation were in 3 cases, tuberculosis inflammation were in 2 cases, lymph nodes were in 2 cases, active tuberculosis were in 1 case, atypical adenomatous hyperplasia was in 1 case and normal lung parenchymal finding was in 1 case, respectively. Conclusion: In our hospital, in order to accomplish a precise histological diagnosis of ground-glass lesion and pulmonary nodules in lung parenchyma, location of pulmonary nodules were exactly located with hook wire under chest computed-tomography, which was followed by lung biopsy. We concluded that this was an accurate, minimally invasive and valuable method to minimize the complications and increase of cost of medical service provided.