The Measurement of Combustible Properties of Cyclopentanol (사이클로펜탄올의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.35-40
    • /
    • 2014
  • For the safe handling of cyclopentanol, this study was investigated the explosion limits of cyclopentanol in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash point of cyclopentanol by using closed-cup cyclopentanol was experimented at $49^{\circ}C$. The lower flash points of cyclopentanol by using open cup tester was experimented at $59^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for cyclopentanol. The experimental AIT of cyclopentanol was at $363 ^{\circ}C$.

The Measurement and Investigation of Fire and Explosion Characteristics of Cyclohexanone (사이클로헥사논의 화재 및 폭발 특성치의 측정 및 고찰)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.28-34
    • /
    • 2011
  • For the safe handling of cyclohexanone, the explosion limits at $25^{\circ}C$ were investigated. The lower flash points and AITs (auto-ignition temperatures) by ignition time delay for cyclohexanone were experimented. By using the literatures data, the lower and upper explosion limits of cyclohexanone recommended 1.1 Vol.% ($100^{\circ}C$) and 9.4 Vol.%, respectively. The lower flash points of cyclohexanone were experimented $42{\sim}43^{\circ}C$ by using closed-cup tester and $49{\sim}51^{\circ}C$ by using open cup tester. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for cyclohexanone and the experimental AIT of cyclohexanone was $415^{\circ}C$.

Appropriateness of MSDS by Means of the Measurement of Combustible Properties of Anisole (아니솔의 연소특성치의 측정에 의한 MSDS의 적정성)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.20-24
    • /
    • 2015
  • For the safe handling of anisole, this study was investigated the explosion limits of anisole in the reference data. The flash points and auto-ignition temperatures (AITs) by ignition delay time were experimented. The lower flash points of Anisole by using closed-cup tester were experimented in $39^{\circ}C$ and $42^{\circ}C$. The lower flash points of Anisole by using open cup tester were experimented in $50^{\circ}C$ and $54^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for Anisole. The AIT of Anisole was experimented as $390^{\circ}C$. The lower explosion limit (LEL) by the measured the lower flash point for Anisole were calculated as 1.07 Vol%.

The Measurement of Combustible Properties of Cyclohexanol (사이클로헥산올의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.64-68
    • /
    • 2014
  • For the safe handling of cyclohexanol, this study was investigated the explosion limits of cyclohexanol in the reference data. The flash points and auto-ignition temperatures (AITs) by ignition delay time were experimented. The lower flash points of cyclohexanol by using closed-cup tester were experimented in$60^{\circ}C{\sim}64^{\circ}C$. The lower flash points of cyclohexanol by using open cup tester were experimented in $66^{\circ}C{\sim}68^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for cyclohexanol. The AIT of cyclohexanol was experimented as $297^{\circ}C$. The lower explosion limit (LEL) and the upper explosion limit UEL) by the measured the lower flash point and the upper flash point of cyclohexanol were calculated as 0.95 Vol% and 10.7 Vol%, respectively.

Measurement and Prediction of Combustion Properties of Styrene (스티렌의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong;Na, Byeong-Gyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.70-76
    • /
    • 2013
  • For the safe handling of styrene, this study was investigated the explosion limits of styrene in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of styrene recommended 0.9 Vol.% and 8.0 Vol.%, respectively. The lower flash points of styrene by using closed-cup tester were experimented $29^{\circ}C{\sim}31^{\circ}C$. The lower flash points of styrene by using open cup tester were experimented $32^{\circ}C{\sim}36^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for styrene. The experimental AIT of styrene was $460^{\circ}C$.

The Measurement of the Combustible Properties of tert-Butylbenzene for the Improvement of MSDS (Material Safety Data Sheet) (MSDS 개선을 위한 tert-Butylbenzene의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.25-30
    • /
    • 2017
  • Because of the vertical combustion characteristics of combustible substances, accurate substance safety information for their safe use, handling and transportation is essential. The flash point, fire point, explosion limits and autoignition temperature (AIT) are important safety parameters which need special attention in chemical plants and laboratories that handle dangerous materials. In this study, tert-butylbenzene which is widely used as an intermediate material in the chemical industry was selected. For the reliability of the flammable properties of tert-butylbenzene, this study was investigated the explosion limits of tert-butylbenzene in the reference data. The flash points, fire points and AITs by the ignition delay time for tert-butylbenzene were experimented. The lower flash points of tert-butylbenzene by using the Setaflash and Pensky-Martens closed-cup testers measured $39^{\circ}C$ and $44^{\circ}C$, respectively. The flash points of tert-butylbenzene by using the Tag and Cleveland open cup testers are measured $51^{\circ}C$ and $54^{\circ}C$. And the fire points of tert-butylbenzene by the Tag and Cleveland open cup testers were $54^{\circ}C$ and $58^{\circ}C$ respectively. The AIT of tert-butylbenzene measured by the ASTM 659E tester was measured as $450^{\circ}C$. The lower explosion limit of $39^{\circ}C$ which measured by the Setaflash flash point tester was calculated to be 0.68 vol%.

폐목재 재활용 분진의 화재폭발위험성

  • Lee, Su-Hui;Han, U-Seop;Han, In-Su
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.115-115
    • /
    • 2013
  • 최근의 분진폭발은 플라스틱, 의약품, 목재, 곡물 저장고, 고체연료, 화학제품 제조공정 등을 포함하여 성형 및 가공 공정 등에서 화재폭발사고가 발생되고 있다. 폐목재를 재활용하여 PB(Particle board)를 생산하는 국내 제조사업장에서는 화재폭발 사고가 빈번히 발생하고 있어 예방대책이 요구되고 있다. 본 연구에서는 폐목재 제조공정의 사고예방과 목재분진 취급공정에 대한 안전대책 등을 제시하기 위하여 사고원인 물질인 폐목재 부유분진의 폭발특성실험을 실시하고 실험결과를 검토하였다. 또한 폐목재 분진의 화재폭발위험성을 상세히 평가하기 위하여 해당 물질의 자연발화점, 축열저장시험, 및 최소점화에너지 등의 화재폭발위험특성값을 실험적으로 조사하였다. 본 연구에서 사용한 폐목재 시료의 비구형 입자형태를 가지는데 입도분석기의 측정 결과 평균 입경은 $15.96{\mu}m$로 조사되었다. 또한 목재 분진의 함수율은 3.88%이며 중금속함유량은 1.73%이다. 자연발화점 측정결과 $225.5^{\circ}C$로서 비교적 낮게 측정되었고 퇴적분진에 대한 화재의 위험성은 높게 나타났다. 반면에 축열저장시험 결과를 통하여 공정관리 온도 및 보관온도를 $150^{\circ}C$ 이하로 관리하면 축열에 의한 자기분해 위험성은 낮은 것으로 판단되었다. 그러므로 축열에 의한 화재폭발 등의 위험성은 낮은 것으로 사료 된다. 최대폭발압력($P_{max}$)은 8.7 bar이며 폭발하한농도 (LEL)는 $60g/m^3$으로 나타났다. 부유분진의 폭발특성실험 결과 분진폭발지수(Kst)는 폭발등급 St 1 (0$bar{\cdot}m/s$)으로 나타났으며 폭발에 의한 위험성이 약한 분진으로 판정되었다. 최소점화에너지(MIE)는 10mJ < MIE <30mJ의 범위로 측정되었으며, 계산에 의해 추정된 최소점화 에너지(Es) 값은 14 mJ로서 일반적인 발화감도(Normal ignition sensitive)로 분류되었다. 이는 실질적인 점화원만 제거하여도 분진폭발을 예방할 수 있다는 것을 의미한다. 그러나 분진 폭발사고를 예방을 위하여 MIE값이 공정운전온도 $100^{\circ}C$ 초과 시에 급격히 낮아질 수 있으므로 운전 온도 설정에 있어서 주의가 필요하다.

  • PDF

A Study on the Spontaneous Ignition Characteristics of Wood Pellets related to Change in Flow Rate (공기유량의 변화에 대한 우드펠릿의 자연발화 특성에 관한 연구)

  • Kim, Hyeong-Seok;Choi, Yu-Jung;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.590-596
    • /
    • 2019
  • Uses of fossil fuels like coal and oil increases with industrial development, and problems like abnormal climate come up as greenhouse gas increases. Accordingly, studies are actively conducted on eco-friendly renewable energy as a replacement for the main resources, and especially, wood pellets with high thermal efficiency are in the limelight as an alternative fuel in thermal power stations and gas boilers. However, despite a constant increase in their usage, few studies are conducted on their risks like fire and spontaneous combustion. Thus, this study found the auto-ignition temperature and critical ignition temperature of wood pellets with a change in flow rate in a thermostatic bath, using a sample vessel with 20 cm in length, 20 cm in height and 14 cm in thickness to predict their ignition characteristics. Consequently, at the flow rate of 0 NL/min, as the core temperature of the sample increased to higher than the ambient temperature, they ignited at $153^{\circ}C$, when the critical ignition temperature was $152.5^{\circ}C$. At the flow rates of 0.5 NL/min and 1.0 NL/min, it was $149.5^{\circ}C$, and at the flow rate of 1.5 NL/min, it was $147.5^{\circ}C$. Consequently, at the same storage, the more the flow rate, the lower the critical ignition temperature became.

벤젠의 최소자연발화온도

  • 하동명;한종근;김한돌;신용범;김일권;유희환;김평호;박영선;김지용
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.82-87
    • /
    • 2004
  • PDF

The Measurement and Prediction of the Fire and Explosion Properties of Isoamyl alcohol (이소아밀알코올의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.34-40
    • /
    • 2016
  • For the safe handling of isoamyl alcohol being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of isoamyl alcohol was experimented. And, the lower explosion limit of isoamyl alcohol was calculated by using the lower flash point obtained in the experiment. The flash points of isoamyl alcohol by using the Setaflash and Pensky-Martens closed-cup testers measured $31^{\circ}C$ and $33^{\circ}C$, respectively. The flash points of isoamyl alcohol by using the Tag and Cleveland open cup testers are measured $43^{\circ}C$and $45^{\circ}C$. The AIT of isoamyl alcohol by ASTM 659E tester was measured as $419^{\circ}C$. The lower explosion limit by the measured flash point $31^{\circ}C$ was calculated as 0.87 vol%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.