• Title/Summary/Keyword: 최소검출 방사능

Search Result 28, Processing Time 0.023 seconds

Determination of Minimum Detectable Activity in Environmental Samples (환경방사능 측정에서의 검출한계치의 정량적 고찰 및 최소검출방사능 농도 계산)

  • Lee, Myung-Ho;Shin, Hyun-Sang;Hong, Kwang-Hee;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.171-184
    • /
    • 1999
  • In this paper, using statistical theory the basic concepts and the formulars of lower limit of detection were deasribed. Assuming that risks of 5% are acceptable (95% confidence level), lower limits of detection were calculated on the measuring apparatus for alpha, beta and gamma nuclides. Also, on the basis concepts of lower limit of detection, the MDA values were calculated for the radionuclides detected easily in the environment. These results make it possible to evaluate confidence limits on the radioanalytical results in the environmental sample.

  • PDF

Survey Study on Radioactivity of Domestic Fishery Product (국내 시중 유통 수산물에 대한 방사능 농도 조사)

  • Kim, Chang-Jong;Lim, Chung-seop;Lee, Wanno;Jang, Mee;Ji, Young-Yong;Chung, Kun-Ho;Kang, and Mun-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.789-792
    • /
    • 2015
  • Samples of fishery products were tested for radioactivity by using the intake frequency data from Korea Health Statistics. The radioactivity of $^{40}K$, $^{137}Cs$, $^{134}Cs$, and $^{131}I$ was analyzed using gamma spectrometry with a simplified sample pre-treatment procedure. The radioactivity range for $^{40}K$ was 21.9-3050 Bq/kg, whereas the radioactivities of $^{137}Cs$, $^{134}Cs$, and $^{131}I$ were under minimum detectable activity which were in the range of 0.140-1.97, 0.0900-1.89 and 0.124-1.94 Bq/kg, respectively, for the three species. The results suggest that the Fukushima accident did not have a significant impact on domestic fishery products, which were analyzed during the period from 2013 to 2015. Additionally, there seemed to be no significant impact of additional exposure dose by the analyzed radionuclides.

Quality Control of Radiation Counting Systems and Measurement of Minimum Delectable Activity (방사선 계측기의 품질관리 및 최소검출방사능 측정)

  • 송병철;한성심;김영복;지광용;손세철
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.419-424
    • /
    • 2004
  • Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the $\gamma$-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 Ops within $2{\sigma}$ confidence levels. The average alpha background level for the low background ${\alpha}{\beta}$ counting system was 0.31 cpm and the efficiency for alpha counting was 34.38%. The average beta background level for the ${\alpha}{\beta}$ counting system was 1,30 cpm and the efficiency for beta counting was 46.5%, The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the$\gamma$-spectrometer was found to be 3.2 Bq/$m\ell$ and 3.8 Bq/$m\ell$ for the liquid scintillation counter, and 20.5 and 23.0 Bq/$m\ell$, respectively for the $\alpha$ and $\beta$ counting system.

  • PDF

Evaluation of Radioactive Stack Air Effluents from the Advanced Fuel Science Building at KAERI (한국원자력연구원 새빛연료과학동 굴뚝방출 방사능 평가)

  • Chang, S.Y.;Kim, B.H.
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Radioactivities of the stack air effluents from the Advance Fuel Science Building (AFSB) at KAERI have been investigated and evaluated. In this AFSB, nuclear fuels for the HANARO research reactor have been fabricated and the advanced nuclear fuels have been studied. A stack air monitoring system has been continuously operating to monitor the stack air effluents from the facility to protect the environment. As the results of the periodical radioactivity measurement and both the gamma and alpha spectrometry for the millipore filters taken from the stack air monitor from January until March 2008, a trace amount of primordial $^{40}K$ and the short-lived decay products of natural borne $^{222}Rn$ and $^{220}Rn$ have been detected. However, the radioactivities have rapidly decayed to the level below the Minimum Detectable Activity (MDA) of the counting system. Therefore, it was evaluated that no uranium isotopes have been released to the atmosphere from the stack of the AFSB at KAERI.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.

A Study of Determination of Minimum Detectable Activity at Measuring of Pu Isotopes in Environmental Samples (환경시료 중 Pu 측정에서 최소검출방사능 농도 산출에 대한 연구)

  • Lee, Myung-Ho;Cho, Young-Hyun;Choi, Gun-Sik;Lee, Chang-Woo;Shin, Hyun-Sang
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.64-71
    • /
    • 2001
  • In this paper, the formula of lower limit of detection considering the measuring time of sample and background was derived using the basic concepts of lower limit of detection. Among parameters affecting the determination of MDA value, the MDA values were calculated with variation of amount of sample and measuring time of sample and background. The results of adequate division between the measuring time of sample and that of background studied in this research make it possible to evaluate confidence limits on the radio analytical results in the environmental sample.

  • PDF

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Determination of 129I in simulated radioactive wastes using distillation technique (증류법을 이용한 모의 방사성폐기물 중 129I 의 정량)

  • Choi, Ke-Chon;Song, Byung-Cheol;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.141-148
    • /
    • 2011
  • It is clarified in the radioactive waste transfer regulation that the concentration of radioactive waste for the major radio nuclide has to be examined when radioactive waste is guided to the radioactive waste stores. In case of the low level radioactive waste sample, the analytical results of radioactive waste concentration frequently show a value lower than minimum detectable activity (MDA). Since the MDA value basically depends on the amount of a sample, background value, measurement time, counting efficiency, and etc, it would be necessary to increase a sample amount with a intention of minimizing MDA. In order to measure a concentration of $^{129}I$ in low and medium level radioactive waste, $^{129}I$ was collected by using a distillation technique after leaching the simulated radioactive waste sample with a non-volatile acid. The recovery of $^{129}I$ measured was compared with that measured with column elution technique which is a conventional method using an anion-exchange resin. The recovery of inactive iodide by using the distillation method and column elution were found as $86.5{\pm}0.9%$ and $87.3{\pm}2.7%$, respectively. The recovery and MDA value calculated for distillation technique when 100 g of extracted solution of $^{129}I$ was taken, were found to be $84.6{\pm}1.6%$ and $1.2{\times}10^{-4}Bq/g$, respectively. Consequently, the proposed technique with simplified process lowered the MDA value more than 10 times compared to the column elution technique that has a disadvantage of limited sampling amount.