• Title/Summary/Keyword: 최대 수명

Search Result 442, Processing Time 0.027 seconds

Effects of Sb doping on the Characteristis of $SnO_2$ Transparent Electrodes ($SnO_2$ 수용전극특성에 미치는 Sb첨가의 영향)

  • 이정한
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.3
    • /
    • pp.16-21
    • /
    • 1976
  • Transparent eloctroaes of polycrystalline till-oxide films doped with antimony are prepared on the substrate of microscopic cover g1ass by modified spray method and from SnCl4 Solution. Their electrical and optical properties are investigated in relation to the surface temperature of the substrate glass and to antimony concentration in the starting materials. The sheet.resiststrace of the film electrodes and transmittance for incandescent light depen on tile antimony concentration and surface temperature of substrates at the time of making films. The transmittance increases with decrease of sheet resistance of the film. The optimum sheet.resistance was obtianed in the case of the antimony concentration 0.6(%) approximately , and the max. transmittance was 93(%).

  • PDF

A Study on Heat Treatment Characteristic of HPDL to Surface Hardening for Press Die(I) - Characteristics of Laser Heat Treatment on FCD550 for Drawing Process - (프레스 금형의 표면경화를 위한 고출력 다이오드 레이저의 열처리 특성에 관한 연구(I) - 드로잉공정 적용을 위한 FCD550 소재의 레이저 열처리 특성 -)

  • Kim, Jong-Do;Song, Moo-Keun;Lee, Chang-Je;Hwang, Hyun-Tae
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.95-95
    • /
    • 2010
  • 자동차 산업에서 차체를 성형하는 프레스 금형 산업은 꾸준히 증가하고 있는 자동차 생산대수와 함께 성장해가고 있으며, 자동차 산업의 국제 경쟁이 심해지고 소비자들의 요구가 다양해짐에 따라 신제품 개발주기에 발맞추어 금형의 제작에도 단납기 및 비용절감을 위한 노력과 제품의 품질 향상을 위해 신기술, 신공법이 적용되고 있다. 한편 자동차 차체를 제작하는 프레스 금형가공은 박판소재를 원하는 형상으로 제작하는 공정으로써, 프레스의 상 하 운동을 이용하여 강판을 성형한다. 이러한 금형의 형태는 곧 자동차 차체 제품의 형태를 완성하므로 제품을 성형하는 도중에 금형과 소재의 마찰에 의해 금형의 마모나 마멸이 발생하여 제품의 품질을 저하시킬 우려가 있다. 따라서 금형의 내마모성 및 수명을 향상시키기 위한 방안들 중 표면경화처리가 행해지고 있으며, 그중 공정 속도가 빠르고 국부적인 열처리가 가능한 레이저 표면처리 방법이 많은 관심을 받고 있다. 본 연구에서는 이러한 금형의 성질을 향상시키기 위해 고출력 다이오드 레이저를 이용하여 프레스 금형공정 중 드로잉(drawing) 공정에의 적용을 위한 표면경화처리를 실시하였다. 최대출력 4.0kW의 다이오드 레이저를 사용하였으며, 6축 외팔보 로봇에 열처리용 광학계를 장착하여 열처리를 실시하였다. 또한 광학계 부근에는 적외선 온도센서가 부착되어있어 열처리시 시험편의 표면온도를 실시간으로 측정할 수 있도록 구성되어져있다. 시험편은 금형재료용 구상흑연 주철인 FCD550 소재를 사용하였으며, 공정변수에 따른 열처리 특성을 파악하고, 그 경화특성을 평가하였다. 실험 결과, FCD550 소재의 표면 열처리시 레이저 출력 3.5kW, 빔 이송속도 3mm/sec에서 최적의 열처리 특성을 나타내었으며, 이때의 최고 경도는 930Hv을 나타내며 모재에 비해 경도가 3배 정도 상승하는 우수한 경화특성을 보였다.

  • PDF

A New Design of Power Folding Controller for Deterioration Detection (열화방지형 파워폴딩 제어기 설계에 관한 연구)

  • Kim, Ji-Hyeon;Lee, Dong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is a study of a prevention of power folding controller's thermal degradation. Power folding technology has been applied for many fields such as side rear vision mirror of vehicles, windshield wiper, antenna, power window. These controllers have been comprised with traditional DC moors, Switching electronic devices, and relays. But this methods have a limitation to overcome such problems of product reliability, endurance, noise margins. Therefore on this paper, to detect the movement of motor, sensing motor brush noise on a load sensing part has been used and controlling a precise RC timing control minimizes the thermal deterioration of motor. And using MOS FETs as a electronic switching device increases life-time and liability of control circuit. After testing such circuit and control method, repetition of operating time, cut-off time, wide operation voltage, power noise margin ware increased over eleven-fold.

Energy-efficient Channel Allocation MAC for Wearable WBANs (웨어러블 WBANs를 위한 에너지 효율적인 채널할당 MAC)

  • Lee, Jung-Jae;Kim, In-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1135-1140
    • /
    • 2016
  • The main challenge in designing wearable WBANs is to guarantee the balance of QoS demands in the network with the low power constraints of limited battery powered nodes. Low power devices implanted in or attached to the body should be designed to meet minimum energy requirements due to their limited battery life and be small in size to be easily wearable. In this paper, we propose a method for optimizing channel allocation method that is compatible with the IEEE 802.15.6 standard, enables the maximum amount of power charge at idle, guarantees the QoS of a WBAN, and provides the reliable date transmission between nodes and hubs in the network. Our extensive simulations will show that the method we propose not only maximizes the QoS in packet transmission but also improves the level of energy efficiency.

Long-term Performance of Highway Embankment Using Tire Shred-Sandy Soil Mixture (재생혼합토(Tire Shred-Sandy Soil Mixture)로 조성된 도로성토구조물의 장기성능)

  • Koh, Taehoon;Hwang, Seonkeun;Yoon, Sungmin;Park, Heemun;Lee, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.5
    • /
    • pp.41-47
    • /
    • 2009
  • In this paper, the long-term performance of highway embankment using tire shred-sandy soil mixture as a lightweight fill material was evaluated through the field monitoring and field test programs. A tire shred-sandy soil embankment was constructed to support a four-lane highway in Indiana, which was built with a 50 : 50 volumetric ratio of tire shreds (maximum particle dimension of 76 mm) and sandy soil (SP, USCS). After opening of the road for traffic, no noticeable differential settlement and lateral deformation were observed, and no adverse environmental impact on temperature was detected as a result of the construction of the tire shred-sandy soil embankment. Moreover, FWD test results showed that tire shred-sandy soil mixture provides bearing capacity comparable to that of conventional fill and meets the criterion for a design life of 20 years.

  • PDF

Establishment of Fatigue Life Evaluation and Management System for District Beating Pipes Considering Operating Temperature Transition Data (운전이력을 고려한 지역난방 열배관의 피로수명 평가 및 관리 체계 구축)

  • Chang Yoon-Suk;Jung Sung-Wook;Kim Hyeong-Keun;Choi Jae-Boong;Kim Sang-Ho;Kim Youn-Hong;Kim Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.9 s.240
    • /
    • pp.1235-1242
    • /
    • 2005
  • A district heating(DH) system supplies environmentally-friend heat and is appropriate for reduction of energy consumption and/or air pollutions. The DH transmission pipe, composed of supply and return pipes, has been used to transmit the heat and prevent heat loss during transportation. The two types of pipes are operated at a temperature of $75\~115^{\circ}C\;and\;40\~65^{\circ}C$, respectively, with an operating pressure of less than 1.568MPa. The objectives of this paper are to systematize data processing of transition temperature and investigate its effects on fatigue life of DH pipes. For the sake of this, about 5 millions temperature data were measured during one year at ten locations, and then available fatigue lift estimation schemes were examined and applied to quantify the specific thermal fatigue life of each pipe. As a result, a relational database management system as well as reliable fatigue lift evaluation procedures is established for Korean DH pipes. Also, since the prototypal evaluation results satisfied both cycle-based and stress-based fatigue criteria, those can be used as useful information in the future fer optimal design, operation and energy saving via setting of efficient condition and stabilization of water temperature.

Development of Electric Power Management System for Electric Furnace (전기로 전력관리 시스템 개발)

  • Min, Byeong-Yong;Kim, Ho-Jin;Kwon, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.904-907
    • /
    • 2013
  • Demand Controller is a control device that if current electric power consumption seems to exceed the targeted amount of electric power, block the connected load devices. When this ON/OFF way is applied to electric power management of electric furnace, start and stop operation of inverter and an electric heater which supplying electric power is being performed repeatedly. This has a problem of life-shortening of inverter and an electric heater by electrical damage. In addition, when electric power supplying is blocked, attemperation is not allowed until return to normal operation condition. In this paper, we develop power management system for electric furnace using the electric furnace remote controller. This system provides the automatic control for approved electric power to electric furnace organically and prevent electric damage of inverter and an electric heater through continuous electric power supply within the targeted amount of electric power.

  • PDF

A Study on the Classification System of National Construction Project based on WBS (WBS 기반의 국책 건설사업 기록물 분류체계에 대한 연구)

  • Jeong, Ki-Ae;Jung, Kuk-Hwan;Kim, Chang-Ha
    • Journal of Information Management
    • /
    • v.41 no.1
    • /
    • pp.173-200
    • /
    • 2010
  • National construction project for SOC(Social Overhead Capital) is led by the government and invested high cost and all capabilities for long times. In general case the life times of SOC facilities are permanently. According to the long life time of the facilities documents and records of national projects are also retained permanently. Consistent classification systems are required to operation and maintenance of the facilities efficiently and to support the organic co-works for several Stakeholders. Therefore the classification of national construction projects are based on WBS of the project. WBS is the hierarchy structure that established and developed in project management project management methodology to produce deliverables of the projects. As a result, this study provides a prospect of project records classification systems in the 21st Century.

Evaluation of Acceleration Effect of Ancillary Services on Cavitation and Fatigue of a Water Turbine in Pumped-Storage Plants (부수적 서비스 제공에 따른 양수발전소 수차의 캐비테이션 및 피로에 대한 가속효과 평가)

  • Kim, Jong Sung;Kim, Se Na
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.225-232
    • /
    • 2017
  • Several maintenance issues related to cavitation erosion and fatigue cracks in the water turbine subcomponents of pumped-storage plants, such as a runner and a draft tube, have been reported in the past. Generally, the pumped-storage plants provide ancillary services, such as black-start and system stabilization. The ancillary services are responsible for cyclic low opening operation of the guide vanes. It has been empirically established that this low opening operation further damages the water turbine subcomponents. In this study, the acceleration effect of the low opening operation on the cavitation erosion and fatigue of the water turbine is quantitatively assessed through finite element flow analysis, finite element stress analysis, and fatigue analysis. As a result of the assessment, it is identified that the cavitation potential increases and the turbine efficiency decreases with a decrease in the opening of the guide vane. Also, the low opening operation has an insignificant effect on the fatigue even though it increases the maximum stress values at the runner blade roots.

Evaluation of Physical and Mechanical Characteristics of Korean Epoxy Asphalt Mixtures (국산 에폭시 아스팔트 혼합물의 물리.역학적 특성 평가)

  • Kim, Byung-Hun;Baek, Jong-Eun;Lee, Hyun-Jong;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2012
  • This study evaluated the performance of Korean epoxy asphalt mixtures using several laboratory tests. Four types of epoxy asphalt mixtures were manufactured based on 13mm dense graded asphalt mixtures: three Korean and one Japanese epoxy asphalt mixtures where 20% or 40% of asphalt binder was replaced by epoxy resins. Curing time was determined as 3 and 6 hours for the mixtures containing 40% and 20% of epoxy resins, respectively. From the laboratory tests including wheel tracking, indirect tension fatigue, bending beam, and moisture susceptibility tests, it was concluded that the epoxy asphalt mixtures had superior performance than conventional asphalt mixtures except moisture susceptibility. Also, the performance of the Korean epoxy asphalt mixtures was comparable to the Japanese mixtures. Thermal coefficient, bond strength, and indirect tension tests were conducted to examine the applicability of the Korean epoxy asphalt mixtures to concrete repair. Its adhesion was strong enough to be bonded to surrounding concrete materials and its tensile strength was comparable to the concrete, but thermal expansion coefficient was 5 times greater than the surrounding concrete.