• Title/Summary/Keyword: 최대환기량

Search Result 83, Processing Time 0.031 seconds

Effect of the Visually Handicapped's Participation in an Aerobic Exercise Program on Cardiorespiratory Function and Arterial Pulse Wave (유산소 운동프로그램 참여가 시각장애인의 호흡순환기능 및 동맥파속도에 미치는 영향)

  • Kim, Won-Hyun;Kim, Seung-Suk
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.337-344
    • /
    • 2013
  • This research has been conducted to determine the effect that the visually handicapped's participation in an aerobic exercise program has on cardiorespiratory function and arterial pulse wave. The subjects of this research were 20 people who have a 1st degree visual impairment. They recognized the purpose of this research and agreed to take part in it. After receiving agreements from their guardians, we divided them into an exercise group of 10 and a comparison group of 10 at random. The exercise group conducted a 50-70%HRmax treadmill exercise for 60 minutes a day, five times a week, for 12 weeks, including warm up and warm down exercises. We then conducted a two-way repeated ANOVA, which regards the period of exercise and the two groups as independent variables. The follow-up verification for exercise periods according to each group was carried out with a paired t-test. The statistical significance level was p<.05. The following are the results of this research. First, the weight and body fat of the experiment group after exercise show a meaningful reduction compared to before the exercise program (p<.05).Second, the VO2max, HRmax, and VEmax of the experiment group after exercise show a meaningful increase compared to before the exercise program (p<.05). Third, the arterial pulse wave of the experiment group after exercise display a meaningful increase compared to before the exercise program (p<.05). Fourth, the systolic blood pressure of the experiment group after exercise does not show a meaningful reduction compared to before the exercise program (p>.05). These results prove that the visually handicapped's participation in an aerobic exercise program is effective in the improvement of their cardiorespiratory function, bloodstream circulation function and blood vessel function.

Influences of Aerobic Exercise Training and Half Bath on Blood Component, Cardiorespiratory Function, and Vascular Compliance of Middle-aged Obese Men (유산소성운동과 반신욕처치가 비만 중년남성의 혈액성분, 호흡순환기능 및 혈관탄성에 미치는 영향)

  • Kim, Seung-Suk
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.541-550
    • /
    • 2012
  • The purpose of this study was to investigate the effect of aerobic exercise training and half bath on blood component, cardiorespiratory function, and vascular compliance of middle-aged obese men. The subjects were 3 groups; aerobic exercise(n=10), half bath(n=10), and controlled group(n=10). They were tested on their blood component, cardiorespiratory function, and vascular compliance at the beginning and at the end of the 12-week study(pre-post test). For data analysis, mean and standard deviation scores were calculated, and repeated measure two-way ANOVA and Scheffe were used. The results of this study are as follows. First, aerobic exercise group was significantly improved on all blood component after the 12-weeks, and showed significant difference among groups. Half bath group was better than control groups on Triglyceride, LDL-C, and HDL-C levels. Second, aerobic exercise group was significantly improved on maximum oxygen uptake, maximum heart rate, and maximum ventilation after the 12-weeks. Third, in vascular compliance measured in both hands and both feet, the half bath group and aerobic exercise training group were significantly increases the control group. Therefore, these results imply that aerobic exercise and half bath can be helpful for better blood component, cardiorespiratory function, and vascular compliance in middle-aged obese men.

Aerobic Exercise's Influence on Obese Female College Students'Arterial Pulse Wave Velocity, Cardiorespiratory Systems and Body Composition (유산소 운동이 비만 여자대학생의 동맥맥파속도, 호흡순환계 및 신체조성에 미치는 영향)

  • Kim, Seung-Suk
    • Journal of Digital Convergence
    • /
    • v.15 no.7
    • /
    • pp.407-414
    • /
    • 2017
  • In order to identify an Convergence aerobic exercise's influence on obese female college students' Cardiorespiratory systems and arterial pulse wave Velocity, this study targeted female college students in D University in Y-gu, D-City, and selected total 26 ones having body fat percentage over 30% with no special disease in past and at present and no regular physical activity. After finally confirming their participation in this experiment by completely explaining the purpose of and contents of this experiment and getting the subjects' written contents to participate in the experiment, the investigator randomly arranged the subjects into the exercise group(N=13) and the control group(N=13) and conducted a 12-week aerobic exercise program to the exercise group this study got the following conclusion. First, concerning the body composition's change, the exercise group showed significant reduction in the weight, the body fat percentage, and the abdominal fat percentage. Second, for the respiratory & cardiovascular systems'change, the exercise group showed significant increase in the maximal oxygen uptake, the maximal heart rate, and the maximal breathing capacity. Third, for the arterial pulse wave Velocity's change, the exercise group showed significant reduction in the upper body(right and left hands) and lower body (right and left feet).

An Optimized Hardware Design for High Performance Residual Data Decoder (고성능 잔여 데이터 복호기를 위한 최적화된 하드웨어 설계)

  • Jung, Hong-Kyun;Ryoo, Kwang-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5389-5396
    • /
    • 2012
  • In this paper, an optimized residual data decoder architecture is proposed to improve the performance in H.264/AVC. The proposed architecture is an integrated architecture that combined parallel inverse transform architecture and parallel inverse quantization architecture with common operation units applied new inverse quantization equations. The equations without division operation can reduce execution time and quantity of operation for inverse quantization process. The common operation unit uses multiplier and left shifter for the equations. The inverse quantization architecture with four common operation units can reduce execution cycle of inverse quantization to one cycle. The inverse transform architecture consists of eight inverse transform operation units. Therefore, the architecture can reduce the execution cycle of inverse transform to one cycle. Because inverse quantization operation and inverse transform operation are concurrency, the execution cycle of inverse transform and inverse quantization operation for one $4{\times}4$ block is one cycle. The proposed architecture is synthesized using Magnachip 0.18um CMOS technology. The gate count and the critical path delay of the architecture are 21.9k and 5.5ns, respectively. The throughput of the architecture can achieve 2.89Gpixels/sec at the maximum clock frequency of 181MHz. As the result of measuring the performance of the proposed architecture using the extracted data from JM 9.4, the execution cycle of the proposed architecture is about 88.5% less than that of the existing designs.

Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation (실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 -)

  • Lee, Sang-Do;Yoon, Se-Jin;Lee, Bok-Hee;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 1993
  • Background: Positive end, expiratory pressure (PEEP) has become one of the standard therapies for adult respiratory distress syndrome (ARDS). Total static compliance has been proposed as a guide to determine the size of PEEP ('best PEEP') which is of unproven clinical benefit and remains controversial. Besides increasing functional residual capacity and thus improving oxygenation, PEEP stimulate prostacyclin secretion and was proposed for the treatment of acute pulmonary embolism. But little is known about the effect of PEEP on hemodynamic and gas exchange disturbances in acute pulmonary embolism. Methods: To study the validity of total static compliance as a predictor of 'best PEEP' in ARDS and acute pulmonary embolism, experimental ARDS was induced in mongrel dog with oleic acid and acute pulmonary embolism with autologous blood clot. Then hemodynamic and gas exchange parameters were measured with serial increment of PEEP. Results:In ARDS group, total static compliance and oxygen transport were maximal at 5 cm$H_2O$, and decreased thereafter (p<0.05). With increment of PEEP, arterial oxygen tension ($PaO_2$) and arterial carbon dioxide tension ($PaCO_2$) increased and cardiac output and physiological shunt decreased. In pulmonary embolism group, total static compliance, oxygen transport, physiological shunt and cardiac output decreased and $PaO_2$ and $PaCO_2$ increased with increment of PEEP (p<0.05). Comparing the change induced by increment of PEEP by 1 cm$H_2O$ in ARDS group with that in pulmonary embolism group, there was no significant difference between two groups except cardiac output which decreased more in pulmonary embolism group (p<0.05). In ARDS group, oxygen transport and total static compliance increased after PEEP application, and total static compliance was maximal at the PEEP level where oxygen transport was maximal. However in pulmonary embolism group, oxygen transport and total static compliance decreased after application of PEEP. There was significant correlation between change of total static compliance and change of oxygen transport in both groups. Conclusion: In both ARDS and acute pulmonary embolism, it can be concluded that total static compliance is useful as a predictor of 'best PEEP'.

  • PDF

A Study on Evaluation of Thermal Environment using Heat Stress Indices for Deep Coal Mine in Korea (열적지표를 적용한 국내 고심도 석탄광산의 열환경 평가 연구)

  • Park, Seon-Oh;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.166-175
    • /
    • 2014
  • In this study, the thermal environment in a large scale coal mine located in Taebaek, Gangwondo was assessed by a field survey. In order to estimate the thermal environment, various heat stress indices such as WBGT, HSI, ESI, KATA index and effective temperature were investigated. Correlation analysis was also conducted. It was found that the thermal environment in most workplace was high. In particular, the correlation coefficient between HSI reflected in physiological fatigue characteristic and the maximum sweat evaporation heat was -0.834. This shows that the correlation coefficient have the most influence on HSI index. The factor which has the most influence on the maximum sweat evaporation heat is velocity of air. The thermal environment of high-depth coal mines is likely to be improved by installing a structure that enables the maximum prevention of extended digging, air doors, or the leakage of the inflow of air in the first shaft.

Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes (중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가)

  • Lee, Sam-Cheol;Kwon, O-Sung;Kim, Ho-Cheol;Hwang, Young-Sil;Lee, Hyun-Cheol
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.

A Study on the Effective Fire and Smoke Control in Semi-Transverse Ventilation (균일배기 환기방식에서의 배연특성에 관한 연구)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Seo, Young-Ho;Yoo, Oh-Ji;Han, Sang-Pil
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.90-94
    • /
    • 2010
  • In this study it is intended to review the moving characteristics of smoke by performing visualization simulation for the calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. If the wind velocity is in the tunnel, the exhaust rate intends to increase rapidly and the exhaust efficiency is decreased. In addition, if the wind velocity is increased, the exhaust rate should be increased in compared with the generation rate of smoke in maximum 1.8 or 1.04 times. In this study, when the wind velocity is in the tunnel, the limited exhaust rate is $84m^3/s{\cdot}250m$. And if it was assumed 1.75 m/s critical velocity in the tunnel, the exhaust rate would be defined $393m^3/s{\cdot}250m$($Q_E$ = 80 + 5Ar).

Separate type heat pipe performance comparison by the heat exchanger shapes (열교환기 형상에 따른 분리형 히트파이프 성능 비교)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.723-729
    • /
    • 2016
  • This study compared fin-tube and parallel-flow heat pipes for their sensible heat exchange rate, heat recovery amount, and air-side pressure drop. Tests were done with different refrigerant charging rates of 40-60% vol. and air flow rates of 300-1,400. The sensible heat exchange rate was highest for both types of heat pipes at a working fluid charge of 40% vol. and low flow rate. For the parallel-flow heat pipe, the 60% vol. charge is too high and results in a low sensible heat exchange rate. The reason is that the thicker liquid film of the tube wall deteriorates the heat transfer effect. Hence, the optimal charging rate is 40 to 50% vol. The evaporator heat pipe has a larger air-side pressure drop than the condenser section heat pipe. The reason is considered to be condensation water arising from the evaporator surface. Compared to the fin-tube heat pipe, the parallel-flow heat pipe showed better performance with a working fluid charging rate of 48%, volume of 41%, and an air-side pressure drop about 37%.

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF