• Title/Summary/Keyword: 최대환기량

Search Result 83, Processing Time 0.023 seconds

Design of a Fourth-Order Sigma-Delta Modulator Using Direct Feedback Method (직접 궤환 방식의 모델링을 이용한 4차 시그마-델타 변환기의 설계)

  • Lee, Bum-Ha;Choi, Pyung;Choi, Jun-Rim
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.39-47
    • /
    • 1998
  • A fourth-order $\Sigma$-$\Delta$ modulator is designed and implemented in 0.6 $\mu\textrm{m}$ CMOS technology. The modulator is verified by introducing nonlinear factors such as DC gain and slew rate in system model that determines the transfer function in S-domain and in time-domain. Dynamic range is more than 110 dB and the peak SM is 102.6 dB at a clock rate of 2.8224 MHz for voiceband signal. The structure of a ∑-$\Delta$ modulator is a modified fourth-order ∑-$\Delta$ modulator using direct feedback loop method, which improves performance and consumes less power. The transmission zero for noise is located in the first-second integrator loop, which reduces entire size of capacitors, reduces the active area of the chip, improves the performance, and reduces power dissipation. The system is stable because the output variation with respect to unit time is small compared with that of the third integrator. It is easy to implement because the size of the capacitor in the first integrator, and the size of the third integrator is small because we use the noise reduction technique. This paper represents a new design method by modeling that conceptually decides transfer function in S-domain and in Z-domain, determines the cutoff frequency of signal, maximizes signal power in each integrator, and decides optimal transmission-zero frequency for noise. The active area of the prototype chip is 5.25$\textrm{mm}^2$, and it dissipates 10 mW of power from a 5V supply.

  • PDF

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF

A Study on Composition and Utilization of Waste Heat Recovery System Assuming Aerobic Liquid-composting Fermentation heat (호기성 액비화 발효열을 가정한 폐열회수시스템 구성 및 활용 연구)

  • Lim, Ryugap;Jang, Jae Kyung;Kang, Taegyung;Son, Jinkwan;Lee, Donggwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.56-66
    • /
    • 2021
  • In this study, a waste heat recovery system was devised and the performances of components incorporated to recover the heat generated during the processing of aerobic liquid-composting in a livestock manure treatment facility were analyzed. In addition, the availability of recovered heat was confirmed. The heat generated by liquid fermentation in the livestock manure treatment facility was also checked. Experimental temperatures were set at 35, 40, and 45 ℃ based on considerations of the uniformity of aerobic liquid-composting fermentation tank temperature and its operating range (34.5 ~ 43.9 ℃). Recovered heat energies from the combined heat exchanger, which consisted of PE and STS pipes, were 53.5, 65.6, 74.4 MJ/h, The heat pump of capacity 5 RT was heated at 95.6, 96.1, 98.9 MJ/h and the heating COPs of the pump were 4.53, 4.62, and 4.65, respectively. The maximum hot water production capacity of the heat exchanger assuming a fermentation tank temperature of 45 ℃ confirmed an energy supply of 56 360 kcal/day. The heating capacity of the FCU linked to the heat storage tank was 20.8 MJ/h, and the energy utilization efficiency was 96.1%. When livestock manure was dried using the FCU, it was confirmed that the initial function rate was reduced by 50.5 to 45.8 % after drying.

Tracheal gas insufflation (TGI) in patients with increased deadspace fraction: the effect and its determining factors (사강호흡율이 증가된 환자에서 기관내 가스주입법(Tracheal Gas Imsufflation)이 가스교환에 미치는 효과와 그 결정인자)

  • Lim, Chae Man;Jung, Bok Hyun;Koh, Youn Suck;Lee, Sang Do;Kim, Woo Sung;Park, Pyung Hwan;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.136-145
    • /
    • 1997
  • Background : Tracheal Gas Insufflation (TGI) is one of the newer ancillary measures in mechanical ventilation employed to enhance carbon dioxide elimination. TGI exerts its effect through reduction of deadspace ventilation, but the factors determining its effect are not well studied yet. Method : The subjects were seven mechanically-ventilated patients ($58.8{\pm}10.6$ yrs) who showed increased physiologic deadspace greater than 60%. After 30 nun of stabilization with 100% oxygen on pressure control ventilation, continuous flow TGI was administered via the insufflation lumen of Hi-Lo Jet Tracheal Tube (Mallincrodt, USA) for 15 min at 3 L/min and 5 L/min each. Results : $PaCO_2$ was decreased ($51.4{\pm}17.6$ at baseline, $49.1{\pm}18.9$ at TGJ 3 L/min $45.0{\pm}14.9$ mm Hg at TGI 5 L/min, p=0.050), and pH was increased ($7.37{\pm}0.12$, $7.38{\pm}0.13$, $7.39{\pm}0.12$, respectively, p=0.037) while mixed expired $CO_2$ ($P_ECO_2$) was not changed significantly from baseline (p=0.336) by TGI. Physiologic deadspace(Vdphy) was decreased ($73.0{\pm}7.9$% at baseline, $69.8{\pm}10.0$% at TGI 3 L/min, and $67.1{\pm}10.1$% at TGI 5 L/min, p=0.015). $AaDO_2$(p=0.147), Vt(p=0.2140), Pmean(p=0.7788) and mean arterial pressure(p=0.4169) were not changed. The correlation between % maximal decrease of Vdphy were r=0.790 with the ratio of baseline Vdana/Vdphy(p=0.035) and r=-0.754 with baseline Vdalv(p=0.050). Conclusion: TGI was effective in reducing $PaCO_2$ and deadspace, and the deadspace-reducing effect was best correlated with baseline anatomic/physiologic deadspace ratio.

  • PDF

A study on verification of exercise intensity and efficiency in Nurida-ball exercise equipment (누리다 볼 운동기구의 운동 강도와 운동 효율성 검증연구)

  • Koo, Jung-Hoon;Cho, We-Hyun;Cho, Joon-Yong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.371-382
    • /
    • 2019
  • The aim of this study was to evaluate the physiological responses following acute and chronic Nurida-ball exercise to measure the relative exercise intensity and health-related fitness in middle-aged men. In study 1, eight middle-aged men carried out acute Nurida-ball exercise for 30 min. The physiological responses were normalized and compared with a graded treadmill exercise test (GXT) to evaluate the relative exercise intensity. In study 2, twelve middle-aged men were divided into two groups: Nurida-ball exercise group (NB, n=6) and control group (CON, n=6). NB group performed the Nurida-ball exercise for 8 weeks (30min/day, 3 days/week). And then, we measured the body composition, cardiovascular factors, blood lipid factors, and muscle damage markers to confirm the exercise efficiency. In study 1, the related exercise intensity of acute Nurida-ball is the range of GXT-HRpeak (55~85%) and $GXT-VO_2peak$(23~61%). The change in body fat-related factors was significantly lower in the NB compared to the CON group. Moreover, TC and LDL were decreased whereas BMC was increased in the NB group after Nurida-ball exercise. The change in VEpeak and performance time of GXT were significantly greater in the NB compared to the CON group. The performance time of GXT was increased in the NB group after Nurida-ball exercise. Our results indicated that Nurida-ball exercise would be effective equipment for the improvement of health-related fitness. Especially, Nurida-ball exercise can affect body composition and cardiovascular function, which might alleviate metabolic syndrome-related diseases in middle-aged men.

Immediate effects of cigarette smoking on exercise in young adult smokers (젊은 성인 흡연자에게 흡연이 운동능에 미치는 즉시효과)

  • Park, In Won;Koh, Hyung Ki;Kang, Yoon Jung;Choi, Jae Sun;Yoo, Jee Hoon;Shin, Jong Wook;Lim, Seong-Yong;Choi, Byoung Whui;Seo, Seung Cheon;Na, Moon Jun;Hue, Sung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Background : Although the long term adverse effects of cigarette smoking on health are well known, the acute possible detrimental effects of smoking on pulmonary or cardiovascular function, especially when these systems are stressed by the metabolic demands of exercise, have not been well studied The purpose of this study is to determine the acute action of cigarette smoking on cardiopulmonary function under stress. Method : Twenty -one healthy smoking subjects were studied. Before exrecise testing, history taking, physical examination and baseline studies, including CBC, chest PA, PFT and EKG, were done. The subjects performed an incremental bicycle exercise test to exhaustion on two occasions, one without smoking and the other after smoking 5 cigarettes/h for 2 hours. All indices of P.F.T. and bicycle ergometry were compared between before and after smoking. Results : 1. $VO_2$max and $O_2$ pulse showed significant decrease in smoking day. 2. Although there were no significant differences, anaerobic threshold showed a tendency of decrease and HRmax showed that of increase in smoking day. 3. P.F.T. and respiratory indices showed no significant change io smoking day. Conclusion : Cigarette smoking has immediate adverse effect, especially on the cardiovascular system rather than the respiratory system. These results would be due to the effect of elevated HbCO and/or impaired blood flow in response to the exercise stimulus.

  • PDF

Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (2) Development of CFD Model to Study the Effect of Tomato Plants on Internal Climate of Greenhouse - (공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (2)온실내 대기환경에 미치는 작물의 영향 분석을 위한 CFD 모델개발 -)

  • Lee In-Bok;Yun Nam-Kyu;Boulard Thierry;Roy Jean Claude;Lee Sung-Hyoun;Kim Gyoeng-Won;Hong Se-Woon;Sung Si-Heung
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.296-305
    • /
    • 2006
  • The heterogeneity of crop transpiration is important to clearly understand the microclimate mechanisms and to efficiently handle the water resource in greenhouses. A computational fluid dynamic program (Fluent CFD version 6.2) was developed to study the internal climate and crop transpiration distributions of greenhouses. Additionally, the global solar radiation model and a crop heat exchange model were programmed together. Those models programmed using $C^{++}$ software were connected to the CFD main module using the user define function (UDF) technology. For the developed CFD validity, a field experiment was conducted at a $17{\times}6 m^2$ plastic-covered mechanically ventilated single-span greenhouse located at Pusan in Korea. The CFD internal distributions of air temperature, relative humidity, and air velocity at 1m height were validated against the experimental results. The CFD computed results were in close agreement with the measured distributions of the air temperature, relative humidity, and air velocity along the greenhouse. The averaged errors of their CFD computed results were 2.2%,2.1%, and 7.7%, respectively.

Effect of Pressure Rise Time on Tidal Volume and Gas Exchange During Pressure Control Ventilation (압력조절환기법에서 압력상승시간(Pressure Rise Time)이 흡기 일환기량 및 가스교환에 미치는 영향)

  • Jeoung, Byung-O;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Lim, Chae-Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.766-772
    • /
    • 2000
  • Background : Pressure rise time (PRT) is the time in which the ventilator aclieves the set airway pressure in pressure-targeted modes, such as pressure control ventilation (PCV). With varying PRT, in principle, the peak inspiratory flow rate of the ventilator also varies. And if PRT is set to a shorter duration, the effective duration of target pressure level would be prolonged, which in turn would increase inspiratory tidal volume(Vti) and mean airway pressure (Pmean). We also postulated that the increase in Vti with shortening of PRT may relate inversely to the patients' basal airway resistance. Methods : In 13 paralyzed patients on PCV (pressure control 18$\pm$9.5 cm $H_2O$ $FIO_2\;0.6\pm0.3$, PEEP 5$\pm$3 cm $H_2O$, f 20/min, I : E1 : 2) with Servo 300 (Siemens-Elema, Solna, Sweden) from various causes of respiratory failure, PRT of 10 %, 5 % and 0 % were randomly applied. At 30 min of each PRT trial, peak inspiratory flow (PIF, L/sec), Vti (ml), Pmean (cm $H_2O$) and ABGA were determined. Results : At PRT 10%, 5%, and 0%, PIF were 0.69$\pm$0.13, 0.77$\pm$0.19, 0.83$\pm$0.22, respectively (p<0.001). Vti were 425$\pm$94, 439$\pm$101, 456$\pm$106, respectively (p<0.001), and Pmean were 11.2$\pm$3.7, 12.0$\pm$3.7, 12.5$\pm$3.8, respectively (p<0.001). pH were 7.40$\pm$0.08, 7.40$\pm$0.92, 7.41$\pm$0.96, respectively (p=0.00) ; $PaCO_2$ (mm Hg) were 47.4$\pm$15.8, 47.2 $\pm$15.7, 44.6$\pm$16.2, respectively (p=0.004) ; $PAO_2-PaO_2$ (mm Hg) were 220$\pm$98, 224$\pm$95, 227$\pm$94, respectively (p=0.004) ; and $V_n/V_T$ as determined by ($PaCO_2-P_E-CO_2$)/$PaCO_2$ were 0.67$\pm$0.07, 0.67$\pm$0.08, 0.66$\pm$0.08, respectively (p=0.007). The correlation between airway resistance and change of Vti from PRT 10% to 0% were r= -0.243 (p=0.498). Conclusion : Shortening of pressure rise timee during PCV was associated with increased tidal volume, increased mean airway pressure and lower $PaCO_2$.

  • PDF

Mechanism improvement of the heat exchanger and the ventilator for the thermal efficiency increment of hot-air heater (온풍난방기의 열이용효율 증대를 위한 열교환부 및 송풍기 구조개선)

  • 이기명;박규식;최성우
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.558-563
    • /
    • 2002
  • 시설원예에서 난방장치를 사용하는 겨울철 재배 농산물의 생산비 중 난방 연료비가 30%~37% 정도를 차지하여 비중이 가장 높다. 따라서 시설원예 농가에서는 난방비를 절감하는 것이 농가소득과 직결되므로, 난방장치의 선정이 대단히 중요하다. 본 연구에서는 겨울철 재배 농산물의 생산비 중 30%-37% 정도를 차지하는 연료비를 절감하기 위해 기존의 온풍난방기와 다른 새로운 방식의 열교환기와 원심식 송풍블로워를 사용하는 블로워 송풍방식의 온풍난방기를 개발하고 개발된 온풍난방기의 가동으로 인한 난방 연료비 절감효과와 온실내의 균일한 온도분포를 획득하기 위해 8연동 비닐온실에서의 시험을 실시하였으며 얻어진 결과를 요약하면 다음과 같다. 가. 저 정압용의 전동기 축직결식 송풍팬을 대신하여 고 정압용의 블로워 송풍팬을 장착하고 열교환 면적을 크게 한 지그재그식 환류의 열교환실을 채용한 온풍난방기를 개발하였다. 나. 공시한 온실에서 기존 온풍난방기의 2일 가동시 DH당 연료 사용량이 평균 1.082$\ell$/$^{\circ}C$.hr 이며, 블로워 송풍방식 온풍난방기의 3일 가동시 DH당 연료 사용량은 평균 0.854$\ell$/$^{\circ}C$.hr로써 21%의 난방 연료비 절감효과가 나타났다. 다. 블로워 송풍방식 온풍난방기는 동일시간대 3$^{\circ}C$의 경시적 온도변화가 발생하였고, 기존의 은풍난방기의 동일시간대 온도변화는 최대 6.1$^{\circ}C$로 나타나 개발된 블로워 송풍방식 온풍난방기가 동일시간대 온실내의 온도변화를 크게 줄일 수 있었고 온도분포를 비교적 균일하게 하는 효과가 있음을 확인하였다.도 33$^{\circ}C$를 기준으로 한 열 회수 시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$ 일 각각 120분 및 140분으로 나타났다. (3) 제 3종 자갈: 축열조로 공급되는 공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때, 축열조 출구의 공기온도가 33$^{\circ}C$에 도달될 때까지 가열되는데 소요된 시간은 가열공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때 각각 180분과 150분이었고, 방열에 소요된 시간은 각각 240분 및 270분으로 나타났다. 방열과정 동안 축열조 출구의 최고 공기온도는 가열 공급공기의 온도가 52$^{\circ}C$$65^{\circ}C$일 때 각각 35.5$^{\circ}C$ 및 39.5$^{\circ}C$였다. 출구 공기온도 33$^{\circ}C$이상을 기준으로 한 에너지 회수시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$일 때 각각 140분 및 160분으로 나타났다. 이와 같이 자갈이 작을수록 축열조 출구의 공기온도가 기준온도 33$^{\circ}C$에 도달되는 시간이 길었으며, 이것은 축열조내의 공극이 작고 비중량이 커 자갈층을 가열시키는 축열시간이 길어지기 때문인 것으로 사료된다. 또한 작은 자갈일수록 방열시간도 다소 길어져 회수 가능 열에너지가 큰 것으로 나타났다

  • PDF

Effect of Kegel Exercise Using Pressure Biofeedback Unit for 2 Weeks on Maximum Voluntary Ventilation and Abdominal Muscle Thickness (2주간 압력 생체되먹임 기구를 이용한 케겔 운동이 최대 자발적 환기량과 배 근육 두께에 미치는 영향)

  • Park, Han-Kyu;Lee, Jung-Hee;Kim, Cho-Hee;Yoon, Ju-Mi;Jo, Ye-Eun;Lee, So-Hee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.175-185
    • /
    • 2022
  • Purpose : This study was conducted to determine the effect of Kegel exercise using a pressure biofeedback unit (PBU) for 2 weeks on maximum voluntary ventilation (MVV) and abdominal muscle thickness based on previous studies. Methods : The subjects of this study were 20 healthy female students in their 20s. Subjects were randomly assigned to two groups. Eleven subjects were assigned to the experimental group (EG) and 9 subjects were assigned to the control group (CG). Subjects measured MVV with a spirometer. In hooklying position, transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) of the dominant side were measured using ultrasound. For the measurement value, the average value of three times was adopted. After 2 weeks of intervention, the measurements were measured in the same way. In the EG, pelvic setting training using PBU was performed before Kegel exercise. The PBU was first placed at the waist in the Kegel exercise position and the starting pressure was set at 40 mmHg and adjusted to 60 mmHg through pelvic floor muscle contraction. After performing pelvic control using PBU, Kegel exercise was performed with 8 seconds of contraction, 8 seconds of relaxation, and 3 sets of 10 reps per set. A significance level of 𝛼=.05 was used to verify statistical significance. Results : In the variable of MVV, a significant increase was confirmed in the EG (p<.05). In the abdominal muscle thickness variable, significant increases were confirmed in IO and TrA in the EG (p<.05). In addition, a significant increase in IO was confirmed in the CG (p<.05). Significant increases in IO and TrA were confirmed between groups (p<.05). Conclusion : Based on the previous study, this study confirmed that Kegel exercise using a PBU had a positive effect on MVV and abdominal muscle thickness based on a 2-week intervention.